Page 251

imNumberPadOn – Visual Basic

3

Example '**************** imNumberPadOn ******************** REM $INCLUDE: 'im20vbas.bi' ' Initializing Variables NumberPadTest$ = "" Temp$ = "" CLS status% = imNumberPadOn(imNumlockOff) PRINT "numpad enable NL OFF" PRINT "<ENTER> when done: " INPUT NumberPadTest$ PRINT status% = imNumberPadOn(imNumlockOn) PRINT PRINT "numpd enable NL ON" PRINT "<ENTER> when done: " INPUT NumberPadTest$ PRINT PRINT "Press any key to quit." INPUT Temp$ END

3-85

Page 252

imPowerStatus – Visual Basic imPowerStatus Purpose:

This function returns the line status, battery status, backup status, and percentage of remaining battery life.

Syntax:

REM $INCLUDE: 'im20vbas.bi' FUNCTION imPowerStatus% (VARPTR(LineStatus), VARSEG(LineStatus) VARPTR(BatteryStatus), VARSEG(BatteryStatus) VARPTR(BackupStatus), VARSEG(BackupStatus) VARPTR(FuelGauge), VARSEG(FuelGauge))

IN Parameters:

None.

OUT Parameters:

The LineStatus parameter returns one of these constants: imAclineNotConnected imAclineConnected imUnknownAcline

AC line is not connected AC line is connected AC line status is unknown

The BatteryStatus parameter returns one of these constants: imHighBat imLowBat imCriticalBat imChargingBat imUnknownBat

Battery charge is high Battery charge is low Battery charge is critical Battery is charging now Battery condition is unknown

The BackupStatus parameter returns one of these constants: imBackupOk imBackupLow

Backup battery is OK Backup battery is low

The FuelGauge parameter returns one of these constants: 0–100 255 Return Value:

3-86

% of full charge in increments of 10% Unknown

This function returns one of the standard status codes defined in Appendix A, “Status Codes.”

Page 253

imPowerStatus – Visual Basic

3

Example '**************** imPowerStatus ******************** REM $INCLUDE: 'im20vbas.bi' PRINT "imPowerStatus" acLine% = -1 battery% = -1 backup% = -1 fuel% = -1 status% = -1 status% = imPowerStatus(VARPTR(acLine%), VARSEG(acLine%), VARPTR(battery%), VARSEG(battery%), VARPTR(backup%), VARSEG(backup%), VARPTR(fuel%), VARSEG(fuel%)) PRINT "ACLine = ", HEX$(acLine%) PRINT "battery = ", HEX$(battery%) PRINT "backup = ", HEX$(backup%) PRINT "fuel = ", HEX$(fuel%) PRINT "status = ", HEX$(status%) END

3-87

Page 254

imProtocolExtendedStatus – Visual Basic imProtocolExtendedStatus Purpose:

This function gets the protocol extended status from the designated communications port. You allocate the protocol status buffer or radio frequency (RF) status buffer, and then imProtocolExtendedStatus returns the status and setup in hexadecimal values.

Syntax:

REM $INCLUDE: 'im20vbas.bi' FUNCTION imProtocolExtendedStatus% ( PortID , VARPTR(StatusBuffer), VARSEG(StatusBuffer))

IN Parameters:

The PortID parameter identifies the communications port as follows: imCom1 imCom2 imCom4

COM1 COM2, scanner port (2010 and 2050) COM4 (RF only)

The StatusBuffer parameter is a far pointer to a buffer structure. Use one of these constants: imCommStatusBufferS (as shown in the syntax above) imCommStatusBufferRF OUT Parameters:

None.

Return Value:

This function returns one of the standard status codes defined in Appendix A, “Status Codes.”

See Also:

imReceiveBufferNoWait, imTransmitBufferNoWait

3-88

Page 255

imProtocolExtendedStatus – Visual Basic

3

Example '**************** imProtocolExtendedStatus ********* REM $INCLUDE: 'im20vbas.bi' 'Extend status protocol buffer DIM statusBuffer AS imCommStatusBufferS 'Initialize status buffer ' Note: Must assign StatusStrVersion as below to return proper ' status statusBuffer.StatusStructureVersion = CHR$(StatusStrVersion) statusBuffer.HandlerVer = STRING$(LEN(statusBuffer.HandlerVer), CHR$(0)) statusBuffer.HandlerType = 0 statusBuffer.Specific.BaudRate = 0 statusBuffer.Specific.Parity = CHR$(0) statusBuffer.Specific.StopBits = CHR$(0) statusBuffer.Specific.DataBits = CHR$(0) statusBuffer.Specific.ModemStatus = CHR$(0) statusBuffer.Specific.PortStatus = CHR$(0) statusBuffer.Specific.ActiveProt = 0 statusBuffer.Specific.LrcEnabled = CHR$(0) statusBuffer.Specific.IntercharDelay = 0 statusBuffer.Specific.TurnaroundDelay = 0 statusBuffer.Specific.ReceiveTimeout = 0 statusBuffer.Specific.TransmitTimeout = 0 statusBuffer.Specific.PolChar = CHR$(0) statusBuffer.Specific.SelChar = CHR$(0) statusBuffer.Specific.ResChar = CHR$(0) statusBuffer.Specific.reqChar = CHR$(0) statusBuffer.Specific.affChar = CHR$(0) statusBuffer.Specific.negChar = CHR$(0) statusBuffer.Specific.somChar = CHR$(0) statusBuffer.Specific.txeomLen = CHR$(0) statusBuffer.Specific.txeomChar1 = CHR$(0) statusBuffer.Specific.txeomChar2 = CHR$(0) statusBuffer.Specific.rxeomLen = CHR$(0) statusBuffer.Specific.rxeomChar1 = CHR$(0) statusBuffer.Specific.rxeomChar2 = CHR$(0) statusBuffer.Specific.flowCtrl = CHR$(0) statusBuffer.Specific.MultiDropAddr = CHR$(0) statusBuffer.Specific.MultiDropEnabled = CHR$(0) statusBuffer.Specific.EofLength = 0 statusBuffer.Specific.EofChar = CHR$(0) statusBuffer.Specific.HaveRecvClientBuffer = 0 statusBuffer.Specific.HaveXmitClientBuffer = 0 statusBuffer.Specific.ProtocolMode = 0 ' Call Intermec routine status% = imProtocolExtendedStatus(ImCom1, VARPTR(statusBuffer), VARSEG(statusBuffer)) ' Function call return status PRINT "Extd Prot Stat" PRINT HEX$(status%) temp$ = INPUT$(1) CLS LOCATE 1,1 ' Print first page of status info PRINT "Extd Status,Pg1of3" PRINT "Strut Ver = ", ASC(statusBuffer.StatusStructureVersion)

3-89

Page 256

imProtocolExtendedStatus – Visual Basic

PRINT "Hd Ver = ", statusBuffer.HandlerVer PRINT "Hd Type = ", statusBuffer.HandlerType PRINT "Baud = ", statusBuffer.Specific.BaudRate PRINT "Parity =", ASC(statusBuffer.Specific.Parity) PRINT "Stop =", ASC(statusBuffer.Specific.StopBits) PRINT "Data =", ASC(statusBuffer.Specific.DataBits) PRINT "Modem =", ASC(statusBuffer.Specific.ModemStatus) PRINT "Port stat = ", ASC(statusBuffer.Specific.PortStatus) PRINT "Ate prot = ", statusBuffer.Specific.ActiveProt PRINT "Lrc enble = ", ASC(statusBuffer.Specific.LrcEnabled) PRINT "Itc dely = ", statusBuffer.Specific.IntercharDelay PRINT "Trnd dely =", statusBuffer.Specific.TurnaroundDelay PRINT "RX tmeout = ",statusBuffer.Specific.ReceiveTimeout PRINT "Xt tmeout = ", statusBuffer.Specific.TransmitTimeout ' Pause between screens PRINT "Any key to cont'" temp$ = INPUT$(1) CLS LOCATE 1,1 PRINT "Extd Status,Pg2of3" ' Print third page of status info PRINT "Pol char = ", ASC(statusBuffer.Specific.PolChar) PRINT "Sel char = ", ASC(statusBuffer.Specific.SelChar) PRINT "Res char = ", ASC(statusBuffer.Specific.ResChar) PRINT "Req char = ", ASC(statusBuffer.Specific.reqChar) PRINT "Aff char = ", ASC(statusBuffer.Specific.affChar) PRINT "Neg char = ", ASC(statusBuffer.Specific.negChar) PRINT "Som char = ", ASC(statusBuffer.Specific.somChar) PRINT "Tx len = ", ASC(statusBuffer.Specific.txeomLen) PRINT "Txchar 1 = ", ASC(statusBuffer.Specific.txeomChar1) PRINT "Txchar 2 = ", ASC(statusBuffer.Specific.txeomChar2) PRINT "Rxlen = ", ASC(statusBuffer.Specific.rxeomLen) PRINT "Rxchar 1 = ", ASC(statusBuffer.Specific.rxeomChar1) PRINT "Rx char 2 = ", ASC(statusBuffer.Specific.rxeomChar2) PRINT "Flow ctrl = ", ASC(statusBuffer.Specific.flowCtrl) ' Pause between screens PRINT "Any key to cont'" temp$ = INPUT$(1) CLS LOCATE 1,1 PRINT "Extd Status,Pg3of3" ' Print second page of status info PRINT "Mul addr = ", ASC(statusBuffer.Specific.MultiDropAddr) PRINT "Mul enble = ", ASC(statusBuffer.Specific.MultiDropEnabled) PRINT "EOF len = ", statusBuffer.Specific.EofLength PRINT "EOF char = ", ASC(statusBuffer.Specific.EofChar) PRINT "Recv clt = ", statusBuffer.Specific.HaveRecvClientBuffer PRINT "Xmit clt = ", statusBuffer.Specific.HaveXmitClientBuffer PRINT "Prot mode = ", statusBuffer.Specific.ProtocolMode END

3-90

Page 257

imReceiveBuffer – Visual Basic

3 imReceiveBuffer Purpose:

This function receives the contents of a data buffer from a designated communications port.

Syntax:

REM $INCLUDE: 'im20vbas.bi' FUNCTION imReceiveBuffer% (PortID, UserLength, VARPTR(DataBuffer), VARSEG(DataBuffer) Timeout, VARPTR(CommLength), VARSEG(CommLength))

IN Parameters:

The PortID parameter identifies the communications port as follows: imCom1 imCom2 imCom4

COM1 COM2, scanner port (2010 and 2050) COM4 (RF only)

The UserLength parameter is the maximum number of bytes to receive and must be at least 256 bytes. The DataBuffer parameter is a far pointer to the array where you want to place the received data. This buffer must hold at least 256 bytes. The Timeout parameter is the receive timeout period. You can exit the function before data is received or before the timeout occurs by performing an application break sequence (see your JANUS user’s manual). The return status indicates whether the function was successful, a timeout occurred, or the application break was received. The Timeout parameter is a number or one of these constants: 0 to 32,767 ms 32,768 to 65,534 ms imZeroTimeout imInfiniteTimeout

Integer range See “Setting Timeout Values” in this chapter. No wait Wait forever

If you select imInfiniteTimeout, the function will not return until the end of message character has been received.

3-91

Page 258

imReceiveBuffer – Visual Basic

OUT Parameters:

The CommLength is the actual number of bytes received upon completion of the call.

Return Value:

This function returns one of the standard status codes defined in Appendix A, “Status Codes.”

Notes:

This function does not return a parameter value until an end of message, a buffer is full, a timeout, or an error occurs. You must install a protocol handler to use this function.

See Also:

imReceiveBufferNoWait, imReceiveBufferNoprot, imCancelRxBuffer, imRxCheckStatus

Example '**************** imReceiveBuffer ****************** ' Note: You must have reader services and a communication protocol handler installed ' to enable send/receive buffer functions. ' Run these TSR's at DOS prompt before running these tests: ' rservice ' PHIMEC 1 ( 1 is COM1) REM $INCLUDE: 'im20vbas.bi' ' Data buffer size must be at least 256 bytes CONST buffsize = 300 ' Define fixed length strings of 300 bytes (256 is minimum string buffer) DIM str1 AS STRING * buffsize ' Actual length returned by imReceiveBuffer DIM commLength ' Must be run with Phimec protocol installed PRINT "imReceiveBuffer" PRINT "Phimec protocol" PRINT "Default - 9600 E 7 1" ' Quit with <CR><LF> sequence PRINT "Ctrl JM to quit" PRINT "(<CR><LF>)" ' Init the string str1 = STRING$(buffsize, CHR$(0)) ' Call Intermec function status% = imReceiveBuffer(imCom1, LEN(str1), VARPTR(str1), VARSEG(str1), 10000, VARPTR(commlength), VARSEG(commlength) ' Print results PRINT str1 ' Print return status(s) PRINT

3-92

Page 259

imReceiveBuffer – Visual Basic

3

PRINT "Actual len = ", commlength PRINT "status = ", HEX$(status%) END

3-93

Page 260

imReceiveBufferNoprot – Visual Basic imReceiveBufferNoprot Purpose:

This function receives a text string from the designated port without using the active protocol. Only the PHIMEC.EXE protocol handler supports this function, which is often used to receive a host initialization string before beginning transmission.

Syntax:

REM $INCLUDE: 'im20vbas.bi' FUNCTION imReceiveBufferNoprot% (PortID , UserLength , VARPTR(DataBuffer), VARSEG(DataBuffer) Timeout , EomChar , VARPTR(CommLength), VARSEG(CommLength))

IN Parameters:

The PortID parameter identifies the communications port as follows: imCom1 imCom2 imCom4

COM1 COM2, scanner port (2010 and 2050) COM4 (RF only)

The UserLength parameter is the maximum number of bytes you can receive and must be at least 256 bytes. The DataBuffer parameter is a far pointer to the data array where you want to place the received data. This buffer must hold at least 256 bytes. The Timeout parameter is the receive timeout period. You can exit the function before data is received or before the timeout occurs by performing an application break sequence (see your JANUS user’s manual). The return status indicates whether the function was successful, a timeout occurred, or the application break was received.

3-94