Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 52 of 56

JANUS 2010 Hand-Held Computer (4MB) User's Manual, pages 511 to 520

Pages 511 to 520 of 556

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2010

Page 511

Glossary nugget code39 helconital

G

Accumulate mode Operating mode in which the reader stores scanned information in the reader’s data buffer until the reader receives an enter command. acknowledgment delay Specifies the maximum amount of time that may elapse before the controller determines that a device did not receive the message. AFF Affirmative Acknowledge character. This character enables or disables the handshake event that is an affirmative acknowledge to a message. alphanumeric keypad The alphanumeric keypad is an all-purpose keypad with 52 keys. Although the keypad is smaller than a regular PC keyboard, you use special keys on the reader’s keypad and press key combinations to access all 102 keys that are available on a PC keyboard. The alphanumeric keypad is available in English, French, German, Italian, and Spanish. application break bit A flag in the reader that an application checks when you turn on the reader. If the bit is not set to 1, the application will resume running. If the bit is set to 1, the application will not resume. You press the application break sequence to set the application break bit. application break sequence A series of keys you press to stop an application from resuming after you turn the reader off and then on again. Usually you use these keys when an application is locked up and you do not want to cold boot the reader to clear the memory. Application companion disk One of the disks that Intermec ships with your JANUS reader. This disk contains applications such as Communications Manager and IRLXDESK.EXE. This disk also contains PC card drivers and utilities that control the reader’s operation, prepare the reader to use the different types of PC cards, customize the reader to use the PC card software, and provide you with helpful tools. ASCII American Standard Code for Information Interchange. A standard 7-bit code almost always transmitted with a parity bit for a total of 8 bits per character.

G-3

Page 512

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital ASCII control character One of the first 32 characters (0 through 31 in decimal representation) in the ASCII character set. Each of these characters has a standard control function, such as backspace or carriage return. ATA flash PC card A type of memory PC card that provides additional disk storage space, not more executable conventional memory, on a JANUS reader. audio signals The reader has a beeper and a clicker that produce audio signals that indicate reader status. You can change the beep volume and enable or disable the keypad clicker with configuration commands. Auto-Loader A DOS utility used to change the contents of drive C. You can also use it to configure the reader to operate in any language supported by DOS NLS (National Language Support). You run Auto-Loader on a host computer connected to the reader’s COM1 port. Automatic mode See Scanner mode. automatic shutoff A reader configuration feature that defines the maximum length of time the reader stays on when there is no activity. At automatic shutoff, the contents of reader memory are saved and the reader resumes where it left off when it is turned on again. backlight A light built into the reader display to make it easier to view the reader display in dimly lit environments. backup battery See lithium bridge battery. BAK Bad Program Acknowledgment character. This character is sent from the reader to indicate that the IRL program received from the host could not be successfully compiled.

G-4

Page 513

Glossary nugget code39 helconital

G bar code density Number of data characters that can be represented in a linear unit of measure. Often expressed in characters per inch. bar code label A label that contains a bar code symbol. bar code symbology A scheme for encoding data as bar code. Code 39, Interleaved 2 of 5, and Codabar are examples of different symbologies. battery pack See NiCad battery pack. baud rate The number of discreet conditions or signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). binary file A file that contains a sequence of 8-bit data characters or executable code. Compare to ASCII text file. Binary files require special software for transmission. See also binary file transfer. binary file transfer (BFT) The process or method for transmitting a binary file (such as an executable file) from one computer device to another. boot Usually means to invoke a bootstrap process, which involves building up a system from some simple preliminary instructions or information. Boot Loader menu The menu on the reader used to reboot the reader, to dump the reader’s RAM, to reload or upgrade the reader’s software, or to use Storage mode. Boot Utilities companion disk One of the disks that Intermec ships with your JANUS reader. This disk contains the files you need to load or upgrade the reader’s system software. This disk also contains the README.DOC, a text file that describes important information about the reader that was unavailable when this manual was published. This disk also contains a batch file, INSTALL.BAT, that you can use to install Auto-Loader onto a host computer.

G-5

Page 514

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital bps Bits per second. The unit of measure used to describe the rate of data transmission. For example, 1200 bits per second means that there are 1200 data bits transmitted per second. BRU Base radio unit. A device that transmits messages over radio frequency (RF) waves between a controller and data collection devices. CGA Abbreviation for Color/Graphics Adapter. CGA is a video adapter board. check character A character included within a message for the purpose of performing a check to ensure the accuracy of the message. check digit A character included in a bar code whose value is used to do a mathematical check on the value of the decoded bar code to retain accuracy. client The computer from which you will access drives, directories, files, and programs that are stored on the server. See also server. Codabar A self-checking, discrete bar code symbology that has these 16 characters in its set: 0 to 9, dollar sign ($), colon (:), slash (/), period (.), plus (+), and dash (-). Codabar is commonly used in libraries, blood banks, and air-parcel express applications. The American Blood Commission (ABC) Codabar requires that you retain the start/stop code digits when processing a Codabar symbol. The maximum density for a Codabar symbol is 12.8 characters per inch. Code 2 of 5 (2 of 5) A discrete, self-checking code for encoding numeric data only. The bars encode information and the spaces separate individual bars. It can achieve densities of 15 characters per inch.

G-6

Page 515

Glossary nugget code39 helconital

G

Code 11 A very high density, discrete, numeric bar code developed by Intermec. The character set includes the numbers 0 through 9 and the dash character (-). Each character is represented by a standalone group of three bars with two included spaces. This code is not self-checking. One or two check digits provide data security. Code 11 is most extensively used in labeling telecommunications components and equipment. Its maximum density is 15 characters per inch. Code 128 A very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths. Code 128’s high density makes it useful when printing data in a limited space. Its maximum density is 12.1 alphanumeric characters per inch or 24.2 numeric characters per inch. Code 16K A two-dimensional (stacked rows), ultra-high density bar code symbology. It is based on Code 128 and is used widely to label unit-dose packaging for the health care industry. Code 39 A discrete, variable length, and self-checking bar code symbology. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and dash (-). Code 39 can be extended to the full 128 ASCII character set by use of a two-character encoding scheme (see full ASCII). Its maximum density is 9.8 characters per inch. Code 49 A multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. The character set includes all 128 ASCII characters. Its maximum density is 93.3 alphanumeric characters per inch or 154.3 numeric characters per inch. Code 93 A variable length, continuous bar code symbology using four element widths. It can be used interchangeably with Code 39 when higher density printing is required. The character set is the same as Code 39. Its maximum density is 14.8 characters per inch.

G-7

Page 516

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital cold boot One of two ways to boot the reader; compare to warm boot. A cold boot invokes the BIOS boot sequence, which verifies that the 256K flash system image is not corrupt, clears all memory, and performs a complete power-on self test (POST) to ensure that the hardware and peripherals are operational. The cold boot initializes the system hardware for use by system software, loads the default configuration, runs AUTOEXEC.BAT and CONFIG.SYS, and loads DOS. Because the physical RAM drive is initialized, all files on drive E are lost. You may cold boot the reader to clear the reader’s conventional memory, break out of an application that is locked in an infinite loop, or recover from an error condition. COM port Commonly used short form of communications port. Locations from which data can be passed into and out of the reader. COM ports offer serial communications, which means that data is transmitted one bit at a time over a single line from one computer to another. Communications Manager An application on the reader that lets you transmit and receive files, and see the status of the reader’s COM port. This application is available on the Application companion disk 3. communications protocol A set of rules or standards designed to enable computers to connect with each other and exchange data. An example of a communications protocol is Point-to-Point protocol. Communications Utilities Transmit and receive functions that you can call with PSK functions or software interrupts. Included in the Reader Services programs. Compound Function key The Compound Function key is a special key on the JANUS keypad. You use the key to access characters or perform functions that do not have an actual key on the keypad. When you press , the key is held in a buffer and the Compound Function key icon appears on the reader’s display. Once you press a key other than , the key combination is entered into the reader and the icon disappears from the display.

A

A

A configuration The selected parameters that determine the operating characteristics of an electronic device.

G-8

Page 517

Glossary nugget code39 helconital

G configuration command A configuration command changes the way the reader operates. You can enter a configuration command by typing on the keypad, by scanning a bar code label, or by sending a command from the host computer. configuration file A configuration file is an ASCII text file that contains settings for some or all of the reader’s configuration parameters. Configuration Manager A Reader Services program on the reader that maintains the reader’s current configuration file, ensures that the reader operates according to that configuration, and lets you change the configuration file. Control mode A reader mode you use to temporarily change some of the display parameters at the DOS prompt or when running an application. The parameters are reset when you boot the reader. conventional memory The reader has 4MB of battery-backed dynamic RAM. The first 640K is conventional memory and is virtually the same as that of a PC. You can use this memory to run applications. cursor keypad A set of keys on the reader that allows you to move the cursor around the screen. data bits The number of bits the reader uses when communicating with another device (i.e., host computer). Generally set at seven or eight. default configuration The values set for each configuration parameter when the reader is shipped. device Any physical item that is attached to a computer. A terminal, a printer, a reader, and a controller are all devices. device driver A software component that controls an external device. For example, a PC card device driver controls how the reader accesses the PC card.

G-9

Page 518

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital DLE The ASCII Data Link Exception character. It causes the character that follows it to be received as data, even if it is a protocol character. It allows for the use of control characters in preambles, data strings, and configuration command strings. DOS code pages A code page is a table that relates binary character codes used by a program to keys on the keypad or to characters on the display. All international keypads are translated using an installed DOS code page that contains the standard ASCII character set and a set of national language characters specific to the language the code page supports. downline When devices are connected to a computer, they are connected in a “line.” Downline is a direction relative to the computer. If more than one computer is connected in a line, the upline computers usually handle data processing and the downline computers usually handle data collection and sometimes some data preprocessing. Contrast with upline. DRAM Abbreviation for dynamic random access memory. A type of RAM that stores information in integrated circuits containing capacitors. Since capacitors lose their charge over time, DRAM boards include logic to recharge, or “refresh,” the RAM chips continuously. Since their internal circuitry is simple, DRAMs are more commonly used than static RAMs, even though they are slower. DRAM can hold approximately four times as much data as a static RAM chip of the same complexity. The reader has 4MB of battery-backed DRAM. drive An electromechanical device that reads from and writes to disks. The three types of common disk drives are floppy disk drives, hard disk drives, and PC card drives. driver See device driver. EAN European Article Numbering. International standard bar code for retail food packages corresponding to the Universal Product Code (UPC) in the United States. A reader that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code.

G-10

Page 519

Glossary nugget code39 helconital

G edge triggering A scanner trigger configuration that makes the laser turn on after you pull the trigger and stay on until you pull it a second time. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off. Contrast with level triggering. EMM Expanded Memory Manager. Software that makes expanded memory available to EMS-compatible DOS programs. end device The device in the data collection system that collects and inputs data. environment variable A specification in a program that defines an operating parameter, such as the command path. EOF End of File character. Attached to the last record transmitted in a block of records and after the End of Record (EOR), if the EOF character field is enabled. EOM End of Message character. Sent at the end of reader and host messages. The transmitted and received EOM characters can be defined separately. EOP End of Program block character. Sent by the host after a block of IRL program statements to tell the reader that another block of IRL statements is coming. EOR End of Record character. Attached to the end of every record transmitted by the polled device if the EOR character field is enabled. error message A message from a device or program advising the user of an error that requires intervention to solve. For example, if you receive the error message “Error, incorrect number of parameters” while creating a drive image with MakeDisk, you should verify that the command line is correct and then try again.

G-11

Page 520

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital extended memory System memory above 4MB. The reader is initially configured with 3MB of extended memory available, which is allocated for use by Intermec applications (IC.EXE and IRL). The reader provides extended memory for control and access to RAM above 4MB. The extended memory conforms to XMS specification 2.0. Extended memory is initialized and managed by the HIMEM.SYS driver. extended memory manager Software that makes extended memory available to DOS programs. For example, you must run an extended memory manager such as HIMEM.SYS on the reader to create and use a physical RAM drive. FIFO control register (FCR) First in/first out control register. The FCR contains a hex value that controls how the UART buffer operates. You may need to configure the JANUS to restore a hex value for the FCR in case you turn off the reader while running a communications application that uses UART 16x550 mode. fixed length Characteristic of a bar code symbology in which the number of characters per symbol is predetermined. Opposite of variable length. flash PC card A type of memory PC card that provides additional disk storage space, not more executable conventional memory, on the reader. Flash cards retain their data without the use of a backup battery. flash ROM drive Drives C and D on the reader are ROM drives that are implemented in flash memory. Flash ROM drives are upgradeable, but have limited write capability. Both drives use a file allocation table (FAT) type format. flow control A method for controlling the flow of data between the reader and the serial port. It stops the transmitting device from sending data when the receiving device buffer fills up and starts it again when the buffer empties. Flow control can be done through software (XON/XOFF) or hardware (CTS/RTS). full ASCII An operating mode that sets the reader to properly decode Code 39 or Code 93 labels containing data that includes any of the 128 ASCII characters.

G-12