Page 361
Configuration Command Reference nugget code39 helconital
12
Code 49 Purpose:
Enables or disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a reader encounters a function code, it replaces the function code with the defined string before transmitting the data to the workstation. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.
Default:
Code 49 Enabled, Function Code 1 disabled, Function Code 2 set to CR LF, and Function Code 3 disabled.
Syntax:
CJdata CKdata CLdata CMdata
Code 49 Function Code 1 Function Code 2 Function Code 3
Acceptable values for data are: Code 49:
Scan:
0 1
Disabled Enabled
Function Code 1:
Any two ASCII characters.
Function Code 2:
Any four ASCII characters
Function Code 3:
Any two ASCII characters
One of these bar codes: Disable Code 49
Enable Code 49
*$+CJ0*
*$+CJ1*
*$+CJ0*
*$+CJ1*
12-25
Page 362
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Code 49 (continued) Scan:
To disable any of the function codes, scan one of these bar codes: Disable Function Code 1
Disable Function Code 2
*$+CK*
*$+CL*
*$+CK*
*$+CL*
Disable Function Code 3
*$+CM* *$+CM*
Or:
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix C. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-26
Page 363
Configuration Command Reference nugget code39 helconital
12
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths. It complements Code 39.
Default:
Enabled
Syntax:
CFdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar codes: Disable Code 93
*$+CF0* *$+CF0*
Enable Code 93
*$+CF1* *$+CF1*
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Default:
Standard
Syntax:
CHdata Acceptable values for data are: 0 1 2
Disabled Standard Code 128 UCC/EAN Code 128
12-27
Page 364
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Code 128 (continued) Scan:
One of these bar codes: Disable Code 128
*$+CH0* *$+CH0*
Enable Standard Code 128
*$+CH1* *$+CH1*
Enable UCC/EAN Code 128
*$+CH2* *$+CH2*
Notes:
If you configure Standard Code 128, the reader will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the reader will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as follows: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. There are two ways to enable or disable reader commands: •
Use the Command Processing configuration command described here.
•
Use the Reader Commands option on the Op menu in IC.EXE.
If you want to disable or enable several commands, it is easier to use IC.EXE. For help, see Chapter 5, “Configuring the Reader.”
12-28
Page 365
Configuration Command Reference nugget code39 helconital
Default:
All reader commands enabled
Syntax:
DCdata
12
Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous setting, you disable the override. Note: If you disable all the reader commands ($+DC0), you cannot change the reader’s configuration or exit from an IRL program. To enable the reader commands again, you can use IC.EXE or edit the configuration (.INI) file. Scan:
To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC0*
*$+DC2* *$+DC2*
Or:
*$+DC1*
*$+DC3*
*$+DC3*
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
12-29
Page 366
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Command Processing (continued) 2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Backspace
(continued)
*-*
*+*
*-*
*+*
Backlight
Change Configuration
*%.*
*$+*
Clear
(continued)
*-*
*-*
Enter Accumulate Mode
(continued)
*-*
*+*
*-*
*/*
*+*
*/*
Exit Accumulate Mode
(continued)
*-*
*/*
*-*
*/*
IRL File, Clear
IRL File, Receive
*.$*
*.%*
*.$*
*.%*
IRL File, Transmit
IRL Program, Download
*%%*
*$O*
*%%*
12-30
*$+*
*%.*
*<SI>*
Page 367
Configuration Command Reference nugget code39 helconital IRL Program, Exit
(continued)
*/*
*$*
IRL Program, Resume
IRL Program, Run
*/*
*$.*
*/*
*//*
*$.*
*//*
Laser Off
Laser On
*/%*
*/.*
Viewport Down
Viewport Up
*%+*
*%/*
Viewport Left
Viewport Right
*%-*
*.-*
Viewport End
Viewport Home
*/%*
*%+*
*%-*
*..%.*
*/.*
*%/*
*.-*
*..%/*
*..%.*
*..%/*
Viewport Page Down
Viewport Page Up
*..%-*
*..%+*
*..%-*
*..%+*
Viewport to Cursor
Cursor to Viewport
*/-*
*..%%*
Alternate Key Code Entry
Multiple-Read Labels
*/-*
*..* *..*
12
*..%%*
*
* *
*
12-31
Page 368
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital
Command Processing (continued) Prepare for Reboot
Reboot
*..+%*
*..%$*
*..+%*
*..%$ *
Set Clock
*/+* */+* Note: To disable or enable Command Override or the Enter key, see the next section, “Disabling or Enabling Command Override and Enter.” 3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the reader will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
12-32
Page 369
Configuration Command Reference nugget code39 helconital
12
Disabling or Enabling Command Override and Enter Purpose:
You can use the Command Processing configuration command to disable or enable two additional reader commands: Command Override and Enter. You can also use IC.EXE to disable or enable these two commands. For help, see Chapter 5, “Configuring the Reader.”
Default:
Command Override and Enter enabled
Syntax:
DC<command>data Acceptable values for data are: 0 1
Scan:
Disable command Enable command
To disable or enable Command Override, scan one of these bar codes: Disable Command Override
*/D/KDC$P0* *$+DC<DLE>0*
Enable Command Override
*/D/KDC$P1* *$+DC<DLE>1*
Or:
To disable or enable Enter, scan one of these bar codes: Disable Enter
*/D/KDC$M0* *$+DC<CR>0* Enable Enter
*/D/KDC$M1* *$+DC<CR>1*
12-33
Page 370
JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital Defining the Reader Commands Chapter 11, “Reader Command Reference” describes all the reader commands that you can enable or disable with Command Processing, except Alternate Key Code Entry and Multiple-Read Labels. These two commands are described next.
Alternate Key Code Entry If you enable the Alternate Key Code Entry command, you can use each key’s four-digit hexadecimal key code value in bar code labels to select options, enter data, and move around in IC.EXE, Communications Manager, and the IRL Desktop. For example, you can scan this label to move the cursor to the right in IC.EXE: Cursor Right
*..4DE0* *..4DE0*
If you disable the Alternate Key Code Entry command, the reader will interpret the hexadecimal key code value as regular data rather than as a code for a specific key or action. For help, see “Scanning Bar Codes to Select Menu Options” in Appendix C.
Multiple-Read Labels A bar code label that has a space as the first character after the start code is a multiple-read label. The reader stores a multiple-read label in the buffer until you execute a command to transmit the label or scan a regular label. A regular bar code label is executed as soon as you scan it. If you use Command Processing, IC.EXE, or another method to disable multiple-read labels, the reader processes the bar code label as a regular label and reads and decodes the space as data. Syntax:
<Start Code><SP>data<Stop Code>
Example:
Multiple-read bar code label
*SPA* *,A*
12-34