Page 341

Configuration Command Reference nugget code39 helconital

12

Configuration Commands Listed by Category (continued) Operations Automatic Shutoff, 12-9 Beep Duration, 12-12 Beep Frequency, 12-13 Beep Volume, 12-15 Command Processing, 12-28 Decode Security, 12-43 Display Backlight Timeout, 12-44 Display Contrast, 12-46 Display Mode, IRL, 12-47 Display Setup, 12-48 Internal Drive Reset After Battery Change, 12-60 Key Code Look-Up Table, 12-68 Keypad Caps Lock, 12-69 Keypad Clicker, 12-70 Keypad Ctrl Key Functions, 12-70 Keypad, Numeric, 12-71 Postamble, 12-78 Preamble, 12-79 Scan Ahead, 12-84 Scanner Devices, 12-84 Scanner Mode, 12-85 Scanner Redundancy, 12-86 Scanner Timeout, 12-87 Scanner Trigger, 12-88 Viewport Movement Keys, 12-99 Viewport Movement Mode, 12-99 Viewport Movement Steps, 12-100

12-5

Page 342

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set the End of File (EOF) character to any ASCII character. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.

$+ is the syntax for the Change Configuration command.

command is the syntax for the command you want to change.

For example, the command syntax for EOF is FAdata. To change the EOF configuration, scan this bar code: Enter Accumulate Mode / Change Configuration / Set EOF

*+/$+FA*

*+/$+FA*

2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix C. To set EOF to SOH (Start of Heading), scan this label: SOH

*$A* *<SOH>*

3. Scan the Exit Accumulate Mode bar code label to update the reader’s configuration: Exit Accumulate Mode

*-/* *-/*

12-6

Page 343

Configuration Command Reference nugget code39 helconital

12

Address, Multi-Drop Purpose:

Defines the address of the communications port when you are using the MultiDrop communications protocol. Each multi-drop address has unique POL and SEL characters that are automatically set when you configure the address. For help, see “POL and SEL Combinations for Multi-Drop Protocol” in Appendix C. Note: You must select the communications port and protocol before you can set the parameters to define that protocol. For help, see the ”Communications Protocol, Configure” command later in this chapter.

Default:

A

Syntax:

HCdata where data can be A through Z or 0 through 5.

Scan:

1. Scan this bar code: Enter Accumulate Mode / Change Address

*+/$+HC* *+/$+HC*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-7

Page 344

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

AFF (Affirmative Acknowledge) Purpose:

Enables or disables the handshake event that is an affirmative acknowledge to a message. You must enable both AFF and NEG to have a valid configuration. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command later in this chapter.

Default:

Disabled

Syntax:

PGdata where data can be any ASCII character.

Scan:

To disable AFF, scan this bar code: Disable AFF

*$+PG* *$+PG*

Or:

To set AFF to an ASCII character: 1. Scan this bar code: Enter Accumulate Mode / Set AFF

*+/$+PG* *+/$+PG*

2. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix C. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-8

Page 345

Configuration Command Reference nugget code39 helconital

12

Automatic Shutoff Purpose:

Defines the maximum length of time the reader remains on when there is no activity. When you do not use the reader for the length of time set for this command, the reader automatically shuts off and goes into Suspend mode. The to turn the reader off. reader also goes into a suspend state when you press to turn the reader on again, the reader resumes exactly When you press where it left off and all reader memory is saved.

L

L

Note: The timeout interval is reset when there is data in the transmit or receive buffer of the radio, or when the radio is trying to recover a lost RF connection. Other factors that may effect the interval being reset are input data from a scanner or keyboard, a low battery condition, AC power connection, or an IRL receive command that has not completed properly. When the timeout interval is reset, it must be counted down again. Power Management Tip: You should use the Automatic Shutoff feature to preserve the NiCad battery pack’s power. Note: If the reader is in a communications dock or a power supply is connected to the reader through an optical link adapter, automatic shutoff is disabled. Default:

1 minute

Syntax:

EZdata Acceptable values for data are: 0M 1M-60M 15S

Scan:

Disabled (always on) Shutoff time in minutes 15 seconds

To set the timeout to 15 seconds, scan this bar code: Set Automatic Shutoff to 15 Seconds

*$+EZ15S* *$+EZ15S*

Or:

To set the timeout in minutes: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff

*+/$+EZ* *+/$+EZ*

12-9

Page 346

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Automatic Shutoff (continued) 2. Scan a numeric value for data from these bar codes:

*0*

*1*

*2*

*3*

*0*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

3. Scan this bar code: Timeout in Minutes

*M* *M*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-10

*1*

*5*

*7*

*9*

Page 347

Configuration Command Reference nugget code39 helconital

12

Baud Rate Purpose:

Sets the baud rate for the selected communications port on the reader. The baud rate must match the baud rate of the device (for example, the host computer) that the reader is communicating with. For Polling Mode D protocol, you must set the baud rate to 1200 or higher. For Multi-Drop protocol, you must set the baud rate to 2400 or higher. Note: You must select the communications port and protocol before you set the parameters to define that protocol. For help, see the “Communications Protocol, Configure” command later in this chapter.

Default:

9600 baud

Syntax:

IAdata Acceptable values for data are: 0 1 2 3 4 5 6 7 8

Scan:

110 baud 300 baud 600 baud 1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud

One of these bar codes: 110 Baud

300 Baud

*$+IA0*

*$+IA1*

600 Baud

1200 Baud

*$+IA0*

*$+IA2*

*$+IA1*

*$+IA3*

*$+IA2*

*$+IA3*

2400 Baud

4800 Baud

*$+IA4* *$+IA4*

*$+IA5*

*$+IA5*

12-11

Page 348

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Baud Rate (continued) 9600 Baud

19200 Baud

*$+IA6*

*$+IA7*

*$+IA6*

*$+IA7*

38400 Baud

*$+IA8* *$+IA8*

Beep Duration Purpose:

Defines the low and high beep duration of the default reader beeps. There are two types of beeps: •

Low beep

•

High beep

Default:

50 ms for both the low and high beep

Syntax:

BDdata Acceptable values for data are from 1 to 60000 ms (60 seconds).

Scan:

1. Scan this bar code: Enter Accumulate Mode / Change Beep Duration

*+/$+BD* *+/$+BD*

2. Scan a numeric value for data in milliseconds from these bar codes:

*0* *0*

*2*

*1*

*3*

*2*

*3*

*4*

*5*

*4*

12-12

*1*

*5

Page 349

Configuration Command Reference nugget code39 helconital *6*

*7*

*8*

*9*

*6*

*8*

12

*7*

*9*

3. Scan one of these bar codes to set the duration for the low or high beep: Low Beep

*L* *L*

High Beep

*H*

*H*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Beep Frequency Purpose:

Defines the individual frequencies of the default reader beeps. There are two types of beeps: •

Low beep

•

High beep

Default:

1000 Hz for the low beep 2000 Hz for the high beep

Syntax:

BFdata Acceptable values for data are from 20 to 20,000 Hz (20 KHz). Note: If you set the frequency outside the range of 100 Hz to 10,000 Hz, the beeps are inaudible.

12-13

Page 350

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Beep Frequency (continued) Scan:

1. Scan this bar code: Enter Accumulate Mode / Change Beep Frequency

*+/$+BF* *+/$+BF*

2. Scan a numeric value for data in Hz from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan one of these bar codes to set the frequency for the low or high beep: Low Beep

*L* *L*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

12-14

High Beep

*H*

*H*