Page 91
Helpful Information
B
This appendix explains the login procedures for NetWare servers and describes ARP table entries for TCP/IP applications. It also provides information for setting a security ID, for creating or modifying JANUS.INI files, and for configuring multiple JANUS devices using special batch files.
NetWare Client User Information If you are a NetWare Client user, you must type IMLOGIN instead of LOGIN on your JANUS RF device when logging into a NetWare server. When you reboot your JANUS device, it automatically runs IMLOGIN. You will usually type IMLOGIN in these situations: •
You roam out of range of an access point for an extended period of time and the NetWare server logs your device out. When you return within range of an access point, you need to type IMLOGIN to log back onto the server.
•
You do not transmit any packets using your device for an extended period of time. Your device may be placed in a suspend state, and the NetWare server will log your device out. When you press the button to resume using the device, you must type IMLOGIN to log back onto the network.
L
ARP Table Entry for TCP/IP Applications Intermec recommends that you create permanent entries for all your JANUS RF devices in the ARP (Address Resolution Protocol) table of all the hosts the devices may communicate with. For help on creating ARP tables, see your TCP/IP manual. Note: If the TCP/IP application is running on the device and it initiates an ARP packet to the host, the ARP packet from the device automatically forces an entry into the ARP table. The ARP table maps the IP address to the physical Ethernet address. To make a permanent entry for your JANUS device in an ARP table, you need to know its host name (for example, janus1, janus2), or the IP address, along with the physical Ethernet address of the JANUS device. During installation, the IP address is entered into a HOSTS file along with the host names and any aliases.
Example of HOSTS file 192.9.299.154 192.9.200.155 192.9.200.156 192.9.200.157 accesspoint janus1 janus2 janus3
B-3
Page 92
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
To find out the physical Ethernet address, also called the node address, for a JANUS device internal RF card, load the RL2OEM driver (normally executed in NET.BAT).
Example Showing the Node Address C:\>rl2pcm ROM Version V1.41e Node Type STA, Domain 15 Inactivity Time Out 5 seconds Sniffing On Standby Is: Enabled Int 3, Port 360, Mem 0B00, Node Address 20A6101021 L Max Frame 1514 bytes, Board 1, Frame ETHERNET_II, LSB Mode Board 2, Frame ETHERNET_802.2, LSB Mode
Instructions for making permanent entries into the ARP table are dependent on the host platform (for example UNIX, DOS, OS/2) and the TCP/IP stack being used. For example, if you are using UNIX TCP/IP, you may enter the following command lines. > arp -s janus1 00:20:A6:10:10:21 > arp -s janus2 00:20:A6:10:12:CF > arp -s janus3 00:20:A6:10:12:DC
The first line shows the first entry host name=janus1 with Ethernet address=00:20:A6:10:10:21.
B-4
Page 93
Helpful Information
B
Setting the Security ID on Your JANUS RF Devices As an added security measure, you can set a security ID on all JANUS devices and access points in a 2.4 GHz RF network. All devices must have the same security ID to communicate. Setting the security ID is optional. Run this utility when you have finished configuring each JANUS device. Use the Security ID Configuration disk to: • set or remove a security ID on a JANUS RF device.
• identify the JANUS device node address.
• verify that the JANUS device can synchronize with an access point.
There are two ways to run this utility: •
Connect the JANUS device to a host PC and use Interlnk. The RF setup utility copies the files to the host PC. Your host PC will need 500KB of free disk space on drive C. The utility deletes these files when you exit the program. Follow the procedure to start the utility using Interlnk and then follow the procedure to set the security ID.
•
Copy the entire contents of the Security ID Configuration disk to an SRAM card. Follow the procedure to start the utility using an SRAM card and then follow the procedure to set the security ID.
Note: You need to perform these steps on the JANUS device. You can only see one section of a PC-size screen on the smaller display of a JG2010 or JG2020. Use the viewporting feature to move around the screen. To start the utility using Interlnk 1. Connect your JANUS RF device to the host PC using a null modem cable. To connect a JG2010 or JG2020, you also need a communications dock or optical link adapter. Refer to your JANUS user’s manual for more information. 2. Insert the Security ID Configuration disk in drive A on the host PC. 3. At the DOS prompt on the host PC, type this command and press Enter. a:rfsetup
Note: If the optical link adapter supports the baud rate set to 115200, at the DOS prompt, type rfsetup /h. The utility copies the files from the disk to the drive C on the host PC.
4. Press any key on the host PC keyboard. 5. Reboot the JANUS device by pressing
.
B-5
Page 94
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
To start the utility using an SRAM card 1. Insert the Security ID Configuration disk in drive A on the host PC. 2. Insert a formatted SRAM card into a PCMCIA (PC) drive on the host PC. 3. At the DOS prompt, type this command and press Enter. a:sramset drive where drive is the drive letter of the PC drive on the host PC. 4. Reboot the JANUS device by pressing Note: You can press
?
.
to skip the memory test and save time.
@
On the JANUS screen, when you see the MS-DOS 6.2 Startup screen, choose and press . 5. On the JANUS device, this prompt appears.
@ &A% @ 2$"(# @
Network? Type 6. Type 7. Type
B-6 and press
.
and press
.
and press
.
Page 95
Helpful Information
To set the security ID 1. On the JANUS device, choose the Test/Utilities button and press
2. Press
AM
(tab) to choose the Security ID button and press
@
B @
.
.
B-7
Page 96
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
3. A warning message about the security ID option appears Warning: AccessNet cards communicate only with other AccessNet cards with the same Security ID. Be sure to set the Security ID on all AccessNet cards in the same subnetwork to the same value.
Press
@
@ to choose the Continue button.
4. Enter the security ID and press . You can use up to 20 alphanumeric characters. The security ID is case-sensitive. Or, delete the security ID if you no longer want to use this feature.
5. A message informs you that your security ID has been updated.
@
Your AccessNet security ID has been updated.
Press
B-8 to continue.
Page 97
Helpful Information
B
6. A message informs you that the operation was successful. The message box also informs you of the JANUS device node address. If you are not within range of an access point with the security ID set, you can ignore the message that the JANUS device could not find a Master to synchronize with.
However, if you are within range of an access point and the security ID is correct, the message box informs you that the JANUS device is synchronized to the access point and provides the node address of the access point. For example:
AM AM
Synchronized to 0020a63051df
7. Press 8. Press
@ @
(tab) to choose the Done button and press (tab) to select the Exit button and press
.
.
9. On the host PC, press Alt-F4 to exit Interlnk. The utility deletes the files it copied to drive C. If you installed terminal emulation software on the JANUS device, it will try to start a session with the host.
B-9
Page 98
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Customizing the J24TE.INI File For Intermec terminal emulation installations, the J24TE.INI file is copied from the TE Applications disk to a subdirectory on your host PC. You may want to customize the J24TE.INI file to permanently change your JANUS operating environment. You can customize the J24TE.INI file to enable or disable supported symbologies or to change other operating parameters such as beep volume, display, viewport size and movement. To customize the J24TE.INI file 1. Shell out to DOS during the installation process. 2. Type the following command from a DOS prompt on the host PC to start Intersvr on the host. a:intersvr
3. After Intersvr is running, remove the Installation Utility disk from drive A. Note: Drive A must be empty or this process will not work.
4. Reboot the JANUS device by pressing . When the JANUS device boots, the Microsoft Interlnk Server Version Intermec menu appears along with the server/client drive mapping screen. Note: If you do not reboot the JANUS device while Intersvr is running on the host PC, Interlnk will not load on the JANUS device and you will not be able to access the drives on the host PC.
("
5. At the JANUS DOS prompt, type configuration application (IC.EXE).
and press
@ @
@ to start the
6. Select the LOAD option from the File menu. 7. Select the IM_FLASH\ directory and press
@
8. Select the DRIVEC\ directory and press 9. Select J24TE.INI and press
.
.
.
10. Use IC.EXE to make your configuration changes. See your JANUS user’s manual for more information on IC.EXE.
B-10
Page 99
Helpful Information
11. Select SAVE from the File menu and press
@
B
.
Note: You can omit steps 8-11 if you can type X:\IM_FLASH\DRIVEC\J24TE.INI at the NAME prompt and save the file. Where X is the drive letter on the host PC that you are mapping to. 12. Select EXIT from the File menu. 13. Select No when you are prompted to update the online configuration on the JANUS device. 14. Reinsert the Installation Utility disk in drive A on the host PC.
$7(3
15. Press Alt-F4 on the host PC to exit Intersvr. 16. Type at the DOS prompt on the JANUS device and press You can now continue with the installation.
@
.
Creating a JANUS.INI File For Novell TNVTxxx and NetWare Client for DOS installations, you may want to create a JANUS.INI file to permanently change your JANUS operating environment. You can use a JANUS.INI file to enable or disable supported symbologies or to change other operating parameters such as beep volume, display, viewport size and movement. To create a JANUS.INI file 1. Shell out to DOS during the installation process. 2. On the host PC , edit the \IM_FLASH\DRIVEC\AUTOEXEC.BAT file to change: d:\ic /l e:\janus.ini to d:\ic /l c:\janus.ini
3. Save the changed AUTOEXEC.BAT file. 4. At the DOS prompt on the host PC, type this command to start Intersvr. a:intersvr
5. After Intersvr is running, remove the Installation Utility disk from drive A. Note: Drive A must be empty or this process will not work.
B-11
Page 100
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
6. Reboot the JANUS device by pressing . When the JANUS device boots, the Microsoft Interlnk Server Version Intermec menu is displayed along with the server/client drive mapping screen. Note: If you do not reboot the JANUS device while Intersvr is running on the host PC, Interlnk will not load on the JANUS device and you will not be able to access the drives on the host PC.
("
7. At the JANUS DOS prompt, type configuration application (IC.EXE).
and press
@ to start the
8. Use IC.EXE to make your configuration changes. See your JANUS user’s manual for more information on IC.EXE. 9. Select the SAVE AS option from the File menu. Type the drive letter on the host PC that you are mapping to (refer to the server/client drive mapping screen) and at the NAME prompt and press .
@ @
10. Select the IM_FLASH\ directory and press 11. Select the DRIVEC\ directory and press
.
@
.
@
12. Save the configuration you created as JANUS.INI and press . You are saving the .INI file you created using the configuration application to the drive on the host PC where the JANUS drive C image will be built. This file is written to the JANUS flash memory and becomes a permanent part of your configuration. Note: You can omit steps 9-12 if you type X:\IM_FLASH\DRIVEC\JANUS.INI at the NAME prompt and save the file. Where X is the drive letter on the host PC that you are mapping to. 13. Select EXIT from the File menu. 14. Select No when you are prompted to update the online configuration on the JANUS device. 15. Reinsert the Installation Utility disk in drive A on the host PC.
$7(3
16. Press Alt-F4 on the host PC to exit Intersvr. 17. Type at the DOS prompt on the JANUS device and press You can now continue with the installation.
B-12
@
.