Page 31
CODEnugget iconJANUS 900 MHz TE Quick Reference Guide
Function Key
Bar Code
F19
3270 and 5250 terminals aG F20 aH F21 aI F22 aJ F23 aK F24 aL
*$F19$M* *<ACK>19<CR>*
3270 and 5250 terminals
*$F20$M* *<ACK>20<CR>*
3270 and 5250 terminals
*$F21$M* *<ACK>21<CR>*
3270 and 5250 terminals
*$F22$M* *<ACK>22<CR>*
3270 and 5250 terminals
*$F23$M* *<ACK>23<CR>*
3270 and 5250 terminals
*$F24$M* *<ACK>24<CR>*
31
Page 32
JANUS 900 MHz TE Quick Reference Guide cc oo dd ee 39 nugget icon
Program Attention Keys for 3270 Terminals If you use a 3270 terminal, you might use the program attention keys to send messages to the host. The specific application you use with your system defines these messages. See your application user's manual for details on the messages each program attention key sends. Program attention keys are AID keys. Program Attention Key
Bar Code
PA1
3270 terminals aP PA2 aQ PA3 aW
32
*$A1* *<SOH>1*
3270 terminals
*$A2* *<SOH>2*
3270 terminals
*$A3* *<SOH>3*
Page 33
CODEnugget iconJANUS 900 MHz TE Quick Reference Guide
Troubleshooting You may encounter error messages while running the 900 MHz TE program. Error codes are displayed in the status line portion of the JANUS screen.
Troubleshooting the Status Screen Symbols, words, and numbers are displayed on the status screen to indicate the status of your host session. This status screen is displayed when you press the stat key. The following table lists the host session status screen messages, their IBM equivalents, and their meaning.
Status Screen Symbols Symbol Displayed
IBM Equivalent
Description
Startup none
Power-on sequence in progress.
PLU solid block
Host session is connected to application program (SNA).
SSCP stick figure
Host session is connected to SSCP (SNA).
INACTIVE none
Host session pending LU activation (SNA).
UNOWNED
? in block
Host session is connected to SNA Engine but not to PLU or SSCP.
nnn none nnn is the device ID number of this session.
X
X
Terminal keyboard disabled.
TIME
X clock figure
Communication is in progress.
?+
X ?+
Operations not accepted. Press Reset and try again.
Sys
X System
Keyboard is disabled by the host, wait for host or press Reset to restore keyboard.
ERR none
Displayed when the keyboard is disabled due to an operator error. Press Reset.
<-OP->
X <-stick figure->
User action performed in wrong screen location. Press Reset.
OP>
X stick figure>
User entered more data than the field can hold. Press Reset.
OP NUM
X stick figure NUM
User entered non-numeric data into a numeric field. Press Reset.
-f
Xf
Requested operation is not available. Press Reset.
PROG4nn
X Prog4nn
Error was detected in data from host, nn defines the type of Program Check.
Note: Press a R to reset in 3270 emulation mode or a Z to reset in 5250 emulation mode.
33
Page 34
JANUS 900 MHz TE Quick Reference Guide cc oo dd ee 39 nugget icon
Status Screen Symbols (continued) Symbol Displayed
IBM Equivalent
COMM5nn
XÆ_5nn
Problem with the communication line to the host, nn defines the type of Communication Check.
-s
X -S
Symbol keyed in by user not recognized. Press Reset.
^
^
Host session is in insert mode.
LOCKED none
Terminal keyboard locked due to host transmission.
(xx, yy)
none
The current cursor position (xx, yy) in screen buffer.
Description
Note: Press a R to reset in 3270 emulation mode or a Z to reset in 5250 emulation mode.
Program Error Codes The following table lists terminal emulation program error codes that may appear on the JANUS status screen. These error codes can be cleared from the status line using Reset ( a R ).
Terminal Emulation Program Error Codes
34
Code
Explanation
401
Invalid data stream received.
402
Invalid buffer address received in data stream.
403
Data received following a 1 byte command or an invalid extended data stream.
404
Data stream ended prematurely.
405
Invalid Copy command.
411
Request/Response Unit (RU) too long.
413
Attempted function not supported.
420
Exception response received when BIND specified a definite response.
421
Definite response received when BIND specified an exception response.
422
A NO response is not accepted.
423
Format Indicator (FI) bit not allowed.
430
Sequence number error.
431
Chaining error.
Page 35
CODEnugget iconJANUS 900 MHz TE Quick Reference Guide
Terminal Emulation Program Error Codes (continued) Code
Explanation
432
Bracket error.
433
Data traffic inactive.
434
Direction error.
443
Change Direction (CD) required.
445
Activate Logical Unit (ACTLU) request specifies neither Cold Activation Procedure (COLP) nor Error Recovery Procedure (ERP).
450
BIND profile mismatch error.
451
BIND primary protocol mismatch error.
452
BIND secondary protocol mismatch error.
453
BIND common protocol mismatch error.
454
BIND screen size mismatch error.
455
BIND LU profile mismatch error.
456
BIND LU type 1 mismatch error.
457
BIND cryptography specified.
462
Printer data stream error detected by LU type 1.
470
Unknown data byte Xî00ØÆXî3FØ or XîFFØ.
498
Negative response received.
499
Exception request received.
35
Page 36
JANUS 900 MHz TE Quick Reference Guide cc oo dd ee 39 nugget icon
Reinstalling Terminal Emulation Software Your JANUS device was shipped with terminal emulation installed and IRL removed. However, if you upgrade the reader software you will need to reinstall the TE program. The TE installation utility runs on a host PC in the DOS environment and uses a graphical user interface (GUI) to prompt you for information about your operating environment. Follow the standard upgrade procedure using the companion boot disk to remove TE and reload IRL on your reader. If you specify Yes at the Standard Upgrade prompt, all system files are upgraded on the reader. If you specify No at the System Upgrade prompt, only TE.EXE file is installed on the reader. Note: Use the JANUS 20X0 TE disk containing the installation utility if you want to install TE and related files on drive D. Use MkImage and PutImage to load TE on drive C. See the JANUS user's manual for detailed information about using MkImage and PutImage.
Installation Requirements To use the TE installation utility, your dedicated host PC must meet the following minimum system requirements: •
It is running DOS 5.0 or above without Stacker. If you need to run Stacker, you will need to add a Stacker device driver to the CONFIG.SYS file before the system boots from the install disk.
•
386 SX with 4MB of RAM.
•
10MB of available hard disk space.
•
MS Windows is not active. The install program cannot run from a Windows DOS box.
Processing Overview A custom AUTOEXEC.BAT and CONFIG.SYS are created on the install disk. The DOS system files on the PC are transferred to the install disk and the host PC is booted from the install disk. Files from drive C and drive D are copied from the reader to the PC. If necessary, files are deleted from the contents of drive D to create space for the terminal emulation program and it is copied from the install disk to the drive D work area. The TE.INI file controls deletion of the files. If files are deleted, a message may appear indicating that a file could not be deleted. This is an informational message indicating that a particular file name included in the TE.INI could not be found to be deleted. Ignore the message and continue the install process.
36
Page 37
CODEnugget iconJANUS 900 MHz TE Quick Reference Guide
Next, CONFIG.SYS is modified to install ANSI.SYS to allow display control by the terminal emulation program. At this point in the install process, the program shells out to the DOS prompt. Check or customize AUTOEXEC.BAT, CONFIG.SYS, and the TE.BAT to ensure they are correct. After making custom alterations, type exit and press Enter to return to the install process. Finally, the new image files are created and copied from the host PC to the reader.
Installing TE The TE installation utility copies the contents of drives C and D to the dedicated PC connected to the reader. These files are updated with the TE software and then copied back to the reader when the installation process is completed. Files may be deleted from drive D to create space for the TE programs. To start the install program 1. Connect the reader to the serial port of the installation PC using a null modem cable connected to a communications dock or optical link adapter. 2. Insert the TE installation disk in drive A and edit the last line in the SETUP.BAT file. You can modify the last line in SETUP.BAT to define your TE environment as follows: a:pcsetup /f /s /5250 /jan0
It is recommended that you retain the /f and /s options. These options let you use the shell out to DOS feature, preserve the work file structures, and customize TE on the host PC. /5250 can be changed to /3270 for 3270 keypad support. /jan0 can be changed to /jan1 or /jan2 to specify a different viewport display size. Use /jan1 for 8 x 20 or /jan2 for 16 x 10 display size. The default viewport display size (/jan0) is 16 x 20. Note: The macro options and the Search and Locate Viewport options are not specified in SETUP.BAT. You can shell out to DOS and edit the line that starts JRTE in the TE.BAT file to include these options. See “Starting Terminal Emulation” earlier in this guide for detailed information on modifying these features.
37
Page 38
JANUS 900 MHz TE Quick Reference Guide cc oo dd ee 39 nugget icon
3. Type a:setup and press Enter. 4. Respond to the program prompts. The program asks if you want to perform standard upgrade on your reader. If you respond y to the prompt, you need the JANUS boot companion disk for version 1.30A or above. The installation program pauses for insertion of a software upgrade disk. If you respond n to the prompt, TE installation begins immediately.
Install Options You can use or modify the TE.BAT file installed on drive C as a shortcut for starting the terminal emulation program. TE.BAT can be customized when the install process shells out to DOS. To use the TE.BAT file, type te and press at the DOS prompt to start terminal emulation.
e
You can make the following changes to the TE.BAT file.: •
The JANUS configuration utility (IC.EXE) is called in TE.BAT and allows you to configure the RF (radio frequency) environment parameters such as device address, frequency, and network ID used in your operating environment. This parameter does not need to be in the TE.BAT file.
•
ICYESNO.EXE calculates a cyclical redundancy check (CRC) of the TE executable and displays the version number of the software installed on the reader. This program is not required to run JRTE and can be removed from the TE.BAT file.
•
The RWTSR.EXE is required for reader wedge communications, and must be loaded before JRTE.EXE.
Installation File Structure The files remaining on the PC after the completion of the installation process are: C:\IM_FLASH Contains the new image files and selected tools that were loaded onto the reader. C:\IM_FLASH\DRIVEC Contains elements used to make the drive C image. C:\IM_FLASH\DRIVED Contains the files deleted from drive D to make room for JRTE.EXE.
38
Page 39
CODEnugget iconJANUS 900 MHz TE Quick Reference Guide
Code 39 ASCII Control Code Chart Decimal
Code39
ASCII Character
01
$A
<SOH>
02
$B
<STX>
03
$C
<ETX>
04
$D
<EOT>
05
$E
<ENQ>
06
$F
<ACK>
07
$G
<BEL>
08
$H
<BS>
09
$I
<HT>
10
$J
<LF>
11
$K
<VT>
12
$L
<FF>
13
$M
<CR>
14
$N
<SO>
15
$O
<SI>
16
$P
<DLE>
17
$Q
<DC1>
18
$R
<DC2>
19
$S
<DC3>
20
$T
<DC4>
21
$U
<NAK>
22
$V
<SYN>
23
$W
<ETB>
24
$X
<CAN>
25
$Y
<EM>
26
$Z
<SUB>
39