Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 4

JANUS 900 MHz Radio Frequency Quick Reference Guide, pages 31 to 37

Pages 31 to 37 of 37

The original document is the PDF (180 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec JR2020, Intermec J2010 and Intermec J2050

Page 31

JANUS 900 MHz Radio Frquency Quick Reference Guide Nuggetfont Scan:

1. Scan this bar code: Enter Accumulate Mode / Retry Limit

*+/$+RL* *+/$+RL*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*1* *1*

*2*

*5* *5*

*6*

*6*

*7*

*2*

*7*

*3*

*8*

*3*

*4* *4*

*8*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

RF Protocol Purpose:

Enables RF communications between the JANUS RF device and the controller.

Default:

Enabled

Syntax:

RFdata Acceptable values for data are 0 and 1, corresponding to: 0 1

Disable Enable

33

Page 32

JANUS 900 MHz Radio Frequency Quick Reference Guide Nuggetfont Scan:

One of these labels: RF Protocol Disable

*$+RF0* *$+RF0*

RF Protocol Enable

*$+RF1* *$+RF1*

RFNC Address Note: You can set this parameter in IC.EXE by choosing Network ID, setting Network ID=0, and choosing Next. Purpose:

Identifies the network controller with which the JANUS RF device is trying to communicate. The value set on the network controller determines the device’s setting. The table on the following page lists the network controller address and the corresponding setting for the JANUS RF device. Note: If your 9180 controller has version 2.0 software, you do not need to set this parameter. Note: If your 9180 controller has version 1.3 or earlier, you need to set this parameter.

Default:

RFNC 0

Syntax:

RTdata Acceptable values for data are 0 through 62 (even numbers only). The value for data must correspond to the address of the network controller as shown in the table later in this section.

Scan:

1. Scan this bar code: Enter Accumulate Mode / RFNC Address

*+/$+RT* *+/$+RT*

34

Page 33

JANUS 900 MHz Radio Frquency Quick Reference Guide Nuggetfont 2. Scan a numeric value for data from these bar codes:

*0* *0*

*1* *1*

*2* *2*

*3*

*5* *5*

*6*

*6*

*7*

*7*

*8*

*3*

*8*

*4*

*9*

*4*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

The value for data should correspond to the address set on the network controller. All addresses apply to downline port 1 on the network controller.

35

Page 34

JANUS 900 MHz Radio Frequency Quick Reference Guide Nuggetfont

Network Controller Address

36

Network Controller

Address <data>

Network Controller

Address <data>

0

0

16

32

1

2

17

34

2

4

18

36

3

6

19

38

4

8

20

40

5

10

21

42

6

12

22

44

7

14

23

46

8

16

24

48

9

18

25

50

10

20

26

52

11

22

27

54

12

24

28

56

13

26

29

58

14

28

30

60

15

30

31

62

Page 35

I Index

Page 36

Index

A Acknowledgment Delay, 17, 18, 19 address device, 23 RFNC, 34 antenna, 8–10 attaching, 8

B base radio unit, in an RF system, 7 battery Duty Cycle Percent, 26 Duty Cycle Period, 27 maximizing life, 14 using duty cycle, 15 Battery icon using for troubleshooting, 16 Broadcast Receipt, 18, 20 BRU, See base radio unit

C Channel Allow, 12, 18, 21 channel search enabling, 29 setting radio frequencies, 21 Channel Select, 11, 12, 18, 22 COM4, 12, 13 Communications Manager, using for RF communications, 13 configuration application, See IC.EXE configuring RF configuration parameters, 10, 17 using the RF link, 17 Connect icon or LED, described, 14 Connect icon, using for troubleshooting, 16 Connect LED, using for troubleshooting, 17 controller configuring for version 1.3 or earlier, 11 configuring for version 2.0, 11 configuring the JANUS RF device for different software versions, 11 in an RF system, 7

D data collection system, RF, 7 Data icon or LED, described, 14 default reader configuration, 24 RF configuration parameters, 10 Device Address, 11, 12, 18, 23 Duty Cycle Percent, 15, 17, 18, 26 managing battery power, 26

I

Duty Cycle Period, 15, 17, 18, 27 managing battery power, 27

I IC.EXE using, 18 using to set up RF communications, 17 icons connect, 14 data, 14 understanding, 13 Interactive Configuration application, See IC.EXE Interlnk/Intersvr, using, 13 IRL Desktop, using for RF communications, 13

J J2050 default configuration, 10 troubleshooting, 16 understanding the RF status LEDs, 13 JANUS PSK reference manual, 17 JANUS readers, See also JANUS RF devices managing battery power, 14 troubleshooting, 15 using the RF status icons, 13 JANUS RF devices configuring, 17 configuring for different controller software versions, 11 default configuration, 10 enabling RF communications, 33 in an RF system, 7 loading the RF protocol handler, 12 unloading the RF protocol handler, 12 using RF communications, 13

L LEDs connect, 14 data, 14 understanding, 13 loading the RF protocol handler, 12 Loopback, 18, 29 losing RF communications, 14, 15, 16

N Network ID, 11, 12, 18, 29

P power management, optimizing, 14 problems with RF communications, 15, 16

39

Page 37

JANUS 900 MHz Radio Frequency Quick Reference Guide

R radio frequency setting for channel search, 21 setting the base frequency, 22 radio repeater in an RF system, 7 setting Repeat Count, 31 reader default configuration, 10 readers, See also JANUS RF devices Repeat Count, 11, 18, 31 Retry Limit, 18, 32 RF communications configuring, 10 by scanning bar code labels, 17, 19 the JANUS RF device for network controller software versions, 11 using configuration application, 17 using IC.EXE, 18 using the RF link, 17 enabling RF protocol, 33 loading the RF protocol handler, 12 losing, 14 managing battery power, 14 setting up, 8 switching to serial communications, 13 troubleshooting, 15, 16 understanding the RF status icons and LEDs, 13 unloading the RF protocol handler, 12 using, 13 using Interlnk/Intersvr, 13 RF configuration parameters Acknowledgment Delay, 17, 18, 19 Broadcast Receipt, 18, 20 changing, 11, 17 by scanning bar code labels, 19 using IC.EXE, 18 Channel Allow, 12, 18, 21 Channel Select, 11, 12, 18, 22 configuring for different controller software versions, 11 configuring using the RF link, 17 defaults, 10 Device Address, 11, 12, 18, 23 Duty Cycle Percent, 15, 17, 18, 26 Duty Cycle Period, 15, 17, 18, 27 Loopback, 18, 29 Network ID, 11, 12, 18, 29 Repeat Count, 11, 18, 31 Retry Limit, 18, 32 RF Protocol, 18, 33 RFNC Address, 11, 18, 34 RF interface, defined, 14 RF Protocol, 18, 33

40

RF protocol handler loading, 12 troubleshooting, 15, 16 unloading, 12 RF status connected, 14 data, 14 RF system, overview, 7 RFNC Address, 11, 18, 34

S scanning bar code labels using to configure RF communications, 17 using to configure RF configuration parameters, 19 serial communications switching to RF communications, 13 setting up RF communications, attaching the antenna, 8 software libraries, using for RF communications, 13 software versions, controller configuring the reader for version 1.3 or earlier, 11 version 2.0, 11 standby, described, 26, 27 Storage mode, using, 15

T troubleshooting J2010, 15 J2050, 16 JR2020, 15 using network management commands, 15, 16 using the Loopback parameter, 29

V Vehicle Mount Computer, See also JANUS RF devices. See J2050