Page 1

Quick Reference Guide P/N 060207-002

JANUS 900 MHz Radio Frequency ®

Page 2

Intermec Corporation 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 U.S. technical and service support: 1-800-755-5505 U.S. media supplies ordering information: 1-800-227-9947 Canadian technical and service support: 1-800-688-7043 Canadian media supplies ordering information: 1-800-268-6936 Outside U.S. and Canada: Contact your local Intermec service supplier. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Intermec manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec. Information and specifications in this manual are subject to change without notice. 1996 by Intermec Corporation All Rights Reserved The word Intermec, the Intermec logo, JANUS, IRL, TRAKKER, Antares, Duratherm, Precision Print, PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec Corporation. Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ®) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Page 3

Manual Change Record This page records the changes to this manual. The manual was originally released at -001. Version

Date

Description of Change

002

7/95

JANUS 2050 information added.

Page 4

Contents

Contents Overview of an RF System 7 Setting Up RF Communications 8 Attaching the Antenna 8 Configuring the RF Parameters 10 Unloading and Loading the RF Protocol Handler 12 Using RF Communications 13 Understanding the RF Status Icons and LEDs 13 Managing Your J2010 and JR2020 Battery Power 14 Troubleshooting Your J2010 and Your JR2020 15 Troubleshooting Your J2050 16 Configuring Your JANUS RF Device 17 Using RF Communications 17 Using the Interactive Configuration Application 18 Scanning Bar Code Labels 19 RF Configuration Parameters 19 Acknowledgment Delay 19 Broadcast Receipt 20 Channel Allow 21 Channel Select 22 Device Address 23 Duty Cycle Percent 26 Duty Cycle Period 27 Loopback 29 Network ID 29 Repeat Count 31 Retry Limit 32 RF Protocol 33 RFNC Address 34 v

Page 5

JANUS 900 MHz Radio Frquency Quick Reference Guide Nuggetfont This guide describes how to use radio frequency communications on the JANUS RF devices (J2010 with an RF back and JR2020 handheld data collection computers and J2050 vehicle-mount computer). It also tells you how to attach the antenna and configure the JANUS RF devices. For more help about any other features, refer to your JANUS user’s manual.

Overview of an RF System A radio frequency (RF) data collection system establishes a two-way radio link between a JANUS RF device and a central network controller. The data from the JANUS RF device is sent in real time through the RF system to the network controller and then on to the host computer. The RF link is completely transparent to the user. The following illustration shows one example of an RF data collection system.

9183 Repeater

J2010 with an RF Back

JR2020 (RF)

9181 Base Radio Unit

9180 Network Controller

Host Computer

20X0Q.004

With your JANUS RF device you can move anywhere within range of a base radio unit (BRU) or a radio repeater and transmit data to and from a network controller that is connected to a host computer. If your controller has a 900 MHz RF ISA card installed, you can transmit directly to it. For help in learning about RF systems, refer to your controller user’s manual.

7

Page 6

JANUS 900 MHz Radio Frequency Quick Reference Guide Nuggetfont

Setting Up RF Communications Before you can use RF communications on the JANUS RF device, you need to do the following: •

Attach the antenna to the J2010 with an RF back, JR2020, or J2050.

•

Configure the RF parameters.

•

Make sure that the RF protocol handler is loaded.

Attaching the Antenna Caution The antenna must be attached before turning on the JANUS RF device. The internal radio could be damaged if the antenna is not attached. Conseil Si l’antenna n’est pas attachée avant que l’appareil RF de JANUS soit mise sous tension, la radio interne peut être endommagée. Note: Do not interchange antennas between any of the JANUS RF devices. Each antenna is built specifically for the radio that is installed in the device.

L

1. Make sure the JANUS RF device is switched off. If the JANUS RF device is on, switch it off by pressing . 2. Screw the antenna into the connector of the JANUS RF device. Refer to the following illustrations. 3. Switch on the JANUS RF device by pressing

8

L

.

Page 7

JANUS 900 MHz Radio Frquency Quick Reference Guide Nuggetfont Attaching the J2010 Antenna

20X0Q.002

Attaching the J2050 Antenna

2050U.009

9

Page 8

JANUS 900 MHz Radio Frequency Quick Reference Guide Nuggetfont

Attaching the JR2020 Antenna

20X0Q.003

Configuring the RF Parameters The RF configuration parameters define radio communications between the JANUS RF device and the Intermec RF data collection system. Note: The software version of your 9180 network controller can affect which RF configuration parameters you set. Refer to the next section, “About Your Controller Software Version.”

10

RF Configuration Parameter

Default Setting

Acknowledgment Delay

100 milliseconds

Broadcast Receipt

Enabled

Channel Allow

All channels are excluded from the search pattern

Channel Select

924 MHz

Device Address

0 (turned off)

Page 9

JANUS 900 MHz Radio Frquency Quick Reference Guide Nuggetfont

RF Configuration Parameter

Default Setting

Duty Cycle Percent (reader) Duty Cycle Percent (J2050)

30% 100%

Duty Cycle Period

1 second

Loopback

Disabled

Network ID

Channel search disabled

Repeat Count

0 repeaters

Retry Limit

0 (optimized setting)

RF Protocol

Enabled

RFNC Address

RFNC 0

To configure the JANUS RF device, follow the instructions in “Configuring a JANUS RF Device” later in this guide.

About Your Controller Software Version The software version that is running on your 9180 Network Controller determines the RF configuration parameters you need to set on your JANUS RF devices. If you have a 9180 controller running software version 1.3 or earlier, you do not have some features that the 9180 controller with software version 2.0 and the 9185 Network Controller have. These enhanced features include time broadcast, channel search capabilities, network management, and support for multiple BRUs.

If the 9180 controller is running software version 1.3 or earlier Parameter on JANUS RF device

Must match

Device Address

The address used by the network controller to identify each JANUS RF device.

Channel Select

The channel set for the BRU.

Network ID

0

RFNC Address

A value that is twice the setting on the network controller. For example, if the network controller address is 2, you would set the RFNC address on the JANUS RF device to 4.

Repeat Count

The setting on the network controller.

11

Page 10

JANUS 900 MHz Radio Frequency Quick Reference Guide Nuggetfont

If the 9180 controller is running software version 2.0 or you have a 9185 controller Parameter on JANUS RF device

Must match

Device Address

The address used by the network controller to identify each JANUS RF device.

Channel Select

The channel set for the BRU that is most frequently used by the JANUS RF device.

Network ID

The value entered for the network ID on the network controller.

Note: The Channel Allow parameter must be set if you are going to be communicating on more than one frequency by using the channel search feature. For help in learning about the network controller, base radio unit, and radio repeater, refer to your user’s manual.

Unloading and Loading the RF Protocol Handler The protocol handler for RF communications automatically loads when you boot a JANUS RF device. If you do not need the RF protocol handler, you can unload it. For help in learning about protocol handlers, refer to your JANUS user’s manual. To unload the RF protocol handler •

From the JANUS RF device DOS prompt, type: unload rfph 4

Note: The “4” in the command line indicates you are unloading the protocol handler for COM port 4 (RF interface). If you have unloaded the RF protocol handler, and want to use RF communications without rebooting your JANUS RF device, you can load it again. To load the protocol handler •

From the JANUS RF device DOS prompt, type: rfph 4