The text of a manual · part 4 of 12
JANUS 900 MHz Terminal Emulation for the Model 200 Controller, pages 31 to 40
Pages 31 to 40 of 117
The original document is the PDF (599 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec J2010 and Intermec J2050
Page 31
3 Customizing Your Configuration
Page 32
Page 33
code3 nuggCustomizing Your Configuration
3
This chapter provides information for customizing your JANUS 900 MHz terminal emulation environment.
Changing TE Session Options After you have installed TE software on your JANUS device, you need to configure the software for your unique operating environment. You can change TE configuration options for a session using the methods described below. Note: Preamble and postamble functions are configured using the JANUS configuration application (IC.EXE). Preamble and postamble are disabled with the default configuration. See your JANUS user’s manual for information on using IC.EXE.
Accessing the Configuration Application To change 3270, 5250, and VT/ANSI options using the Configuration Application 1. Start the terminal emulation program. For more information, see “Starting Terminal Emulation” in Chapter 1.
<7
2. Press to access the 3270 or 5250 configuration application. Or,
>I to access the VT/ANSI configuration Press application.
<7 >I or , you bypass the If you do not press configuration application, and your terminal emulation session begins after a 5-second delay. 3. Select Configure TE and press configuration options.
@ to specify
3-3
Page 34
JANUS 900 MHz Terminal Emulation for the Model 200 Controller code2 nugg
: U
@
4. Use the or to highlight the function that you . want to configure and press
@
5. After making your changes, highlight Exit Config to exit the configuration application. and press
6. After entering all configuration parameters, you can save the configuration you created during the session.
3-4
@
• if you want to save the Choose Yes and press configuration options. Configuration options are saved to the RAM drive, drive E.
• if you do not want to Choose No and press save the configuration options. You then exit to the DOS prompt.
• to return to the TE Choose Cancel and press Configuration Menu. This option gives you an opportunity to change or correct the configuration options that you selected.
@
@
Page 35
code3 nuggCustomizing Your Configuration
@
3
7. Choose one of these options on the Exit menu. •
Select Configure TE and press TE Configuration Menu.
•
Select Set Password and press to set a terminal emulation password. For more information on TE passwords, see “Setting Security for the TE Configuration Application” later in this chapter.
•
Select Exit TE and press configuration application.
to return to the
@
@ to exit the
3270 and 5250 Configuration Parameters Use the following screens to enter configuration information for terminal configuration, communications configuration, and viewport movement parameters.
Terminal Text Size Specifies the text size displayed on the JANUS screen. Options are regular height (normal characters) or double height (double high text). Note: Display of double height characters is not supported on the JANUS 2050. Auto Field Advance Enables or disables the auto field advance option. Auto field advance enabled is the default setting.
Communications Upline Protocol Select the protocol you are planning to use. Setting the upline protocol (upline to the Model 200 Controller) to SNA forces the JANUS device to use the SNA 5250 Terminal Session Manager (TSM) on the Model 200 Controller for communicating with the host. Setting the protocol to TELNET forces the client to use the Telnet TSM to communicate via TCP/IP to the host. Both TSM components reside on the Model 200 Controller and are transparent to the terminal emulation user. Host Name Enter the name of the host to which you want the JANUS device to connect. The host name can be up to 15 characters in length.
3-5
Page 36
JANUS 900 MHz Terminal Emulation for the Model 200 Controller code2 nugg
Note: If you have linked a device with a host name on the Model 200 Controller, you do not need to enter a host name on this screen. If you have not linked a device with a host name on the controller, you must enter a host name for this parameter. The host name on this screen must match a host name in the list of available hosts defined on the controller.
Viewport Viewport Mode Specifies one of the following viewport movement modes: •
Follow enables Viewport Follow cursor mode.
•
Center enables Viewport Center mode.
•
Manual disables Viewport movement.
Side Boundary (Follow mode) Controls side movement of the viewport. The viewport moves when the cursor is the specified number of characters from the side boundary. Options are 1 to 10 characters. Side Jump (Follow mode) Specifies the number of characters the viewport moves in a horizontal direction. Options are 1 to 10 characters. Vertical Boundary (Follow mode) Moves the viewport when the cursor is the specified number of characters from the vertical viewport boundary. Options are 1 to 10 characters. Vertical Jump (Follow mode) The JANUS device uses this parameter to control vertical movement of the viewport. Options are 1 to 10 characters.
3-6
Page 37
code3 nuggCustomizing Your Configuration
3
VT and ANSI Configuration Parameters Use the following screens to enter configuration information for terminal configuration, communications configuration, and viewport movement parameters.
Terminal Text Size Specifies the text size displayed on the JANUS screen. Options are regular height (normal characters) or double height (double high text).The default is regular height. Note: Display of double height characters is not supported on the JANUS 2050. Terminal Type Selects the terminal type used by the host system. The supported terminal types are: VT100, VT220, VT320, ANSI, and RDRANSI. Comm Port Select the serial port you are using for terminal emulation. Use COM4 for the RF communications port, or COM1 for CrossBar. The default is COM4. Terminal Mode VT series terminals have different modes to exchange escape sequences, control commands, and status reports with an application. User-Defined Key For VT220/320 only, you can set this field to lock or unlock. There are 15 programmable function keys: F6 through F14, Do, Help, and F17 through F20. When this field is set to Unlock, you can program any of the function keys you want. When you set the field to Lock, the function keys cannot be reprogrammed. The default is Unlock. Keypad Mode VT series terminals have two modes for function keys, editing keys, and numeric keys: Application mode and Numeric mode. These keys generate different key codes depending on the mode your VT terminal is using. The default is Numeric mode. If you select Numeric mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the keys. If you select Application mode, you generate application ESC sequences for the key code. For more information, see Appendix B, “VT/ANSI Keyboard Remapping.”
3-7
Page 38
JANUS 900 MHz Terminal Emulation for the Model 200 Controller code2 nugg
Cursor Mode VT series terminals have two modes for arrow keys: Application mode and Cursor mode. These keys generate different key codes depending on the mode your terminal is using. The default is Cursor mode. Numeric Keypad You can use this field to enable or disable Numeric Keypad mode on the JANUS device. The default is disable. When you enable Numeric Keypad mode, numeric keys function like the numeric keys on the numeric keypad. When you disable Numeric Keypad mode, numeric keys function like the numeric keys on the main keyboard. Input Mode
Options are Line mode or Character mode.
If you select Line mode, you enter a line of characters on your JANUS device and press before it is transferred to the host. In Line mode, communications overhead is reduced because input is sent one line at a time instead of one or a few characters at a time.
@
If you select Character mode, each character you type is immediately sent to the host. Protocol Toggles between 0200R1, standard, and enhanced. You must use the 0200R1 protocol if you want your JANUS device to communicate with the Model 200 Controller. Answerback The answerback string is sent from a connected JANUS device to the host in response to an ENQ from the host or as a key sequence from the user. This field can be up to 30 characters in length. Any ASCII character from 0 to 255 can be entered as part of the answerback string. A carriage return can be placed anywhere in the Answerback field. Enter the following four characters for a carriage return: <cr>.
Communications Host Name Enter the name of the host to which you want the JANUS device to connect. The host name can be up to 15 characters in length and is case sensitive. Note: If you have linked a device with a host name on the Model 200 Controller, you do not need to enter a host name on this screen. If you have not linked a device with a host name on the controller, you must enter a host name for this parameter. The host name on this screen must match a host name in the list of available hosts defined on the controller.
3-8
Page 39
code3 nuggCustomizing Your Configuration
3
Viewport Viewport Mode You can choose the Viewport mode to be auto or manual. Auto Viewport mode enables the viewport to automatically follow the cursor during the terminal emulation session. Manual Viewport mode requires you to move the JANUS viewport to follow the cursor. The default is Auto mode.
Setting Security for the TE Configuration Application You can set a password to control access to the terminal emulation configuration application. When a TE password is enabled, the Verify TE Password screen is displayed when you use a hot key ( for 3270 and 5250 or for VT/ANSI) to access the configuration application.
>-
<7
A TE password can be a maximum of 10 characters in length and is stored in an encrypted form in the TE.SEC file. A password that you set on the device using the TE configuration feature is only valid for the current TE session. When you reconnect to the host through the Model 200 Controller, the permanent password stored on the Model 200 Controller is again downloaded to the connected device and overwrites TE.SEC. Note: The TE.SEC file should be stored on the E drive and NOT on the C drive. Intermec recommends that you keep a backup encrypted TE.SEC file on the C drive in case the E drive version is lost or damaged.
3-9
Page 40
JANUS 900 MHz Terminal Emulation for the Model 200 Controller code2 nugg
To enable or disable the TE password
<7
1. Press (3270 or 5250) or configuration application. 2. Use the .
@
> - (VT/ANSI) to access the TE
: or U to highlight Set Password and press
3. Enter information on the Set TE Password screen then Select OK and press .
@
Old Password This field is for password verification purposes. Asterisks representing the password are displayed on the screen. An error message, “Incorrect Old Password Entry,” appears if the data you enter does not match the original password. Note: Leave this field blank if no password is configured. New Password Type the new password in this field. Asterisks are displayed in the field for each keystroke you enter in this field. To disable the security feature, leave this field blank. Verify Password Type the new password again to verify that it was entered correctly. Asterisks are displayed for keystrokes in this field. Note: To remove an existing password, enter the current password in the Old Password field and leave the New Password and Verify Password fields blank. Choose OK and press to remove password protection.
@
3-10