Page 1

Quick Reference Guide

JANUS 900 MHz Terminal Emulation for the Model 200 Controller P/N 066576-001

Page 2

Intermec Corporation 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 U.S. service and technical support: 1-800-755-5505 U.S. media supplies ordering information: 1-800-227-9947 Canadian service and technical support: 1-800-688-7043 Canadian media supplies ordering information: 1-800-268-6936 Outside U.S. and Canada:

Contact your local Intermec service supplier.

The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Intermec manufactured equipment and is not to be released, reproduced, or used for any other purpose without the written permission of Intermec. Information and specifications in this manual are subject to change without notice. 1997 by Intermec Corporation All Rights Reserved The word Intermec, the Intermec logo, JANUS, IRL, TRAKKER, Antares, Duratherm, Precision Print, PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec Corporation. Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Page 3

Contents

Contents Before You Begin vii Warranty Information vii About This Manual vii Other Related Manuals ix

1

Getting Started Introduction 1-3 Typical 900 MHz Configuration 1-4 Starting Terminal Emulation 1-5 Exiting Terminal Emulation 1-6 Unsupported Functions 1-7

2

Using TE Features Using the JANUS TE Keypad 2-3 JANUS 2010 and 2020 Terminal Emulation Keypads 2-3 JANUS 2050 Terminal Emulation Keypads 2-4 Accessing the Commands on the Keypad 2-5 Accessing Uppercase Letters and Symbols 2-5 Accessing Characters or Commands 2-5 Viewing the Input Screen 2-7 How the Viewport Works 2-7 Understanding the Roll Command 2-8 Auto-Advancing Through Fields on 5250 TE Screens 2-9 Understanding Status Line Messages 2-10

3

Customizing Your Configuration Changing TE Session Options 3-3 Accessing the Configuration Application 3-3 3270 and 5250 Configuration Parameters 3-5 Terminal 3-5 iii

Page 4

JANUS 900 MHz Terminal Emulation for the Model 200 Controller

Communications 3-5 Viewport 3-6 VT and ANSI Configuration Parameters 3-7 Terminal 3-7 Communications 3-8 Viewport 3-9 Setting Security for the TE Configuration Application 3-9 Using the Auto-Login Feature 3-11 Developing Auto-Login Scripts 3-11 Control Characters for Auto-Login Scripts 3-12 Loading the Auto-Login File 3-14 Configuring Terminal Emulation to Display International Characters 3-14 IBM 3270 and 5250 Code Pages 3-14 VT/ANSI Code Pages 3-15 AUTOEXEC.BAT and CONFIG.SYS Changes 3-15

4 iv

3270 and 5250 Commands Command Descriptions 4-3 Arrow Keys 4-3 Attention 4-3 Auto-Login Restart 4-4 Backtab 4-4 Clear 4-4 Cursor Home 4-5 Delete 4-5 End 4-5 Enter 4-6 Erase to End of Field 4-6 Erase Field 4-6 Erase Input 4-7 Erase Last Word 4-7 Error Reset 4-7 Exit 4-8 Fast Cursor Right/Left 4-8 Field+ and Field- 4-9 Field Exit 4-9 Help 4-10 Home 4-10 Insert 4-11 New Line 4-11

Page 5

Contents

Paging Keys 4-12 Reset 4-13 Reshow 4-13 Roll Up and Roll Down 4-14 Scroll 4-15 Status 4-15 System Request 4-16 Tab 4-16 Program Function Keys 4-17 Program Attention Keys 4-20 3270 Keys 4-20 5250 Keys 4-20 Other Keys - 5250 Terminals 4-21

5

VT/ANSI Commands Editing Key Commands - VT220/320 Terminals 5-3 Auto-Login Restart 5-3 Find 5-4 Insert 5-4 Next Screen 5-4 Previous Screen 5-4 Remove 5-5 Select 5-5 Program Function Keys 5-5 Additional Functions 5-8

6 A

Troubleshooting Understanding Error Messages 6-3 Local Editing Errors 6-3

Reference 3270 and 5250 Command Summary A-3 VT220/320 Command Summary A-4 v

Page 6

JANUS 900 MHz Terminal Emulation for the Model 200 Controller

VT/ANSI Additional Functions A-5 JANUS Viewport Movement Commands A-6 Terminal Emulation Files A-7 Reinstalling Terminal Emulation Software A-8 Sample Auto-Login Scripts A-10 TE.CFG Configuration File A-12

B

VT/ANSI Keyboard Remapping Understanding VT/ANSI Key Support B-3 VT100 Terminals B-3 VT220/320 Terminals B-4 ANSI Terminals B-6 Remapping the JANUS Keys B-6

I vi

Index

Page 7

Dnug>JIcode Before You Begin Before You Begin This section introduces you to standard warranty provisions, safety precautions, warnings and cautions, document formatting conventions, and sources of additional product information.

Warranty Information To receive a copy of the standard warranty provision for this product, contact your local Intermec sales organization. In the U.S. call 1-800-755-5505, and in Canada call 1-800-688-7043. Otherwise, refer to the Worldwide Sales & Service list that comes with this manual for the address and telephone number of your Intermec sales organization.

About This Manual This table summarizes the information in each chapter and appendix. Chapter

What You Will Find

1

Provides basic information for setting up and using your JANUS data collection computer with terminal emulation.

2

Describes the JANUS TE keypad and explains how to use terminal functions on the keypad.

3

Tells you how to customize your JANUS terminal emulation configuration.

4

Lists the terminal emulation commands you can use with your 3270 and 5250 terminals.

5

Lists the terminal emulation commands you can use with your VT/ANSI terminals.

6

Provides information about error messages that you may encounter while using terminal emulation software.

A

Provides a summary of available TE commands for all supported devices. It also provides copies of the configuration files included on your TE installation disk.

B

Provides information about VT/ANSI key support and instructions for remapping keys on your JANUS device.

vii

Page 8

D>JInugg

JANUS 900 MHz Terminal Emulation for the Model 200 Controllercode

Terms and Conventions The following special terms and conventions occur throughout the manual.

PC Keypad Input Keystrokes to be entered into the PC are emphasized in bold. “Choose Y” means you press the key labeled “Y” on the PC keyboard. When you need to press and release a series of keys in order, the keys appear in order with no connectors. “Press Shift A” means that you press and release the Shift key, and then press A. When you must press more than one key at the same time, the keys are connected by a dash in the text. “Press Ctrl-Alt-Del” means that to perform a warm boot on the host PC, you need to hold down the Ctrl, Alt, and Del keys at the same time. When the keys are connected by a dash, you must press and hold the keys in the order shown.

@

@

JANUS Keypad Input Key icons represent keystrokes you enter on the JANUS device. For example, “press “ directs you to press the key labeled “ ” on the JANUS keypad. PC and JANUS Commands Command syntax appears in the text as you should enter it into the PC or JANUS device. For example, to see a listing of directories on the device, type the following command: dir Optional command line parameters are enclosed in brackets [ ].

Notes The notes in this manual use the following format. Note: Notes either provide extra information about a topic or contain special instructions for handling a particular condition or set of circumstances. IMPORTANT! Is used to flag critical information about a topic.

viii

Page 9

Dnug>JIcode Before You Begin Format Conventions for Bar Codes You can scan the bar codes listed in this manual to enter data or perform a command. The bar code labels in this manual are printed in the Code 39 symbology. Each bar code includes the name and human-readable interpretation. For example:

Change Configuration

Name

*$+*

Bar code (Code 39) Human-readable interpretation

*$+*

2010U.073

The asterisks (*) at the beginning and end of the human-readable interpretation are the start and stop codes for a Code 39 bar code label. If you are creating bar code labels with a bar code utility, it may automatically supply the asterisks as the start and stop code, so that you only need to type the actual text of the command. You can also create and print configuration labels and reader command labels in Code 93, which has its own start and stop codes.

Other Related Manuals You may need to refer to other manuals when working with JANUS 900 MHz terminal emulation software. To order additional manuals, contact your local Intermec representative. Intermec Manuals

Intermec Part No.

Model 200 Controller System Manual

063439

RF System/9180 Controller User’s Manual

054292

900 MHz RF Equipment User’s Manual

066163

900 MHz RF Gateway User’s Manual

066164

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

065714

JANUS 2020 Hand-Held Computer User’s Manual (4MB)

065715

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB)

065716

Other Manuals Intermec recommends that 5250 users obtain a copy of the IBM 5494 Remote Control Unit Functions Reference Manual for more detailed information regarding 5250 commands, local editing functions, and error messages.

ix

Page 10

This page is a scan with no text; see it in the PDF.