Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 2

IP3 Intellitag Portable Reader (UHF) Quick Start Guide, pages 1 to 6

Pages 1 to 6 of 12

The original document is the PDF (305 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec IP3

Page 1 read from a scan by OCR; it may hold reading errors

Intermec %j |. Quick Start Guide

IP3 Intellitag

Portable Reader (UHF)

Page 2

Packing List Check to ensure that you receive these items: S IntermecR IP3UA1104 Intellitag Portable Reader (UHF) S Battery Pack (p/n: 318-014-001) S Compliance Statement S Warranty Card

Setting up Your 700 Color Mobile Computer Before using your Portable Reader with the 700 Color Mobile Computer you need to load the Portable Reader CAB files onto your mobile computer. Do that by going to either of these two sources: S 700 Series Color Software Tools CD-ROM (p/n: 235-099-001) S Intellitag Developer’s CD (p/n: ITD001)

2

IP3 Intellitag Portable Reader (UHF) Quick Start Guide

Page 3

Connecting the Portable Reader to the 700 Color Mobile Computer RF Exposure regulations limit exposure to radiofrequency (RF) radiation. To comply with these regulations, operators of this device must maintain a distance of at least 20 cm. (8 inches) from the cover on the antenna assembly (The cover on the antenna is the dome shaped surface). While the device is on, the operator’s body and parts of the body such as eyes, hands, or head, must be 20 cm. (8 inches) or farther from the cover of the antenna assembly. Note: DO NOT remove the IR reflector from the inside of the Portable Reader. This IR reflector aids in the communication of the IrDA signal between the Portable Reader and your Mobile Computer

Gold IR Reflector DO NOT REMOVE

IP3 Intellitag Portable Reader (UHF) Quick Start Guide

3

Page 4

1 Slide your Mobile Computer into your Portable Reader. 2 Ensure it slides in all the way. Your Mobile Computer communicates with the Reader via the IrDA. Therefore, the IrDA signal passing from the Portable Reader must have a good IrDA acceptance on the side of the Mobile Computer. You will hear a click when you have the Mobile Computer completely inserted into the Portable Reader. Mobile Computer fully engaged into Portable Reader

3 Attach the two retaining screws. Ensure that they go straight into the mobile computer openings.

Ensure retaining screws go straight into the slots on your mobile computer

4

IP3 Intellitag Portable Reader (UHF) Quick Start Guide

Page 5

Removing the 700 Color Mobile Computer from Portable Reader 4 Remove the two retaining screws. 5 Grasp the 700 Color Mobile Computer at the display end, and simultaneously lift up (away from the Reader), then pull forward.

Portable Reader LED Location and Explanation LEDs position (top to bottom) 1, 2, 3, 4, 5

Reader label

Portable Reader LED Explanation LED

Indicates

Meaning

1

PWR

+5 Power is On. Reader is ready.

2

HOST COMM

Data communication with Host is active.

3

RF ON

RF Power is On.

4

TAG COMM

Valid tag transaction.

5

BATT

Battery condition (Low RED, Full GREEN, more than 20% but less than 80% ORANGE).

IP3 Intellitag Portable Reader (UHF) Quick Start Guide

5

Page 6

Battery Installation and Removal To charge the battery contained in your Portable Reader, it is necessary to remove the battery from the handle and place it in the IP3U Dual Battery Pack Charger. This charging unit charges the battery in four hours. 1 To install the battery into the Portable Reader, insert the battery (tilt to fit into notch) into the compartment opening and press in until the latch on the bottom of the battery snaps closed. The battery tab on the top of the battery pack fits into the notch in the compartment.

Battery tab

Battery latch

2 To remove the battery pack, push the battery release latch forward and remove the battery pack from the handle.

Battery release latch

6