Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 12

IF30 Fixed Reader User's Manual: Chapter 3 - Creating and Using RFID Applications

Pages 53 to 66 of 106, from IF30 Fixed Reader User's Manual

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec IF30

Page 53

3 Creating and Using RFID Applications

This chapter explains how you can use RFID applications for the IF30 and includes these topics: •

RFID Applications and the IF30

•

Creating Applications for the IF30

•

Configuring RFID Settings

•

Configuring the Data Collection Engine

41

Page 54

Chapter 3, Creating and Using RFID Applications

RFID Applications and the IF30 An RFID application communicates with the IF30 through the Data Collection Engine (DCE), and controls the reader by issuing Basic Reader Interface (BRI) commands. •

For more information on the DCE, see “Configuring the Data Collection Engine” on page 49.

•

For more information on the BRI, see the Basic Reader Interface Programmer’s Reference Manual.

Creating Applications for the IF30 An RFID application can communicate directly with the IF30 DCE using the BRI protocol. For more information, see “Configuring the Data Collection Engine” on page 49. To develop RFID applications for the IF30, you will need to write and test your RFID applications on a development workstation (your desktop PC). The application can access the IF30 via TCP on port 2189.

Configuring RFID Settings This section explains how you use the web browser interface to change the settings for the IF30 RFID module. As you install and test applications, you can configure the RFID settings for the best system performance. To change RFID module settings 1 From the menu, click RFID Module. The RFID Module screen appears.

42

IF30 Fixed Reader User’s Manual

Page 55

Chapter 3, Creating and Using RFID Applications

2 Change RFID settings as needed. For help, see the next section. 3 Click Submit Changes to save your changes. To activate your changes, from the menu bar click Save/Discard Changes, and then click Save Changes and Reboot. For help, see “Saving Configuration Changes” on page 16. Note: If you make changes to RFID settings, you need to reboot the IF30 to activate the changes.

IF30 Fixed Reader User’s Manual

43

Page 56

Chapter 3, Creating and Using RFID Applications

About RFID Module Settings This section explains the module settings. Most settings have BRI attribute equivalents. For more information, see the Basic Reader Interface Programmer’s Reference Manual.

Supported Tag Type Sets the type of tag for RFID operations. Certain performance improvements can be realized if you choose the best setting for your system. The more specific the selection, the better the performance. See the next table for more information. Tag Type Descriptions Tag Type

Description

Phillips v1.19

Phillips v1.19

ISO6B/G1

ISO6B Generation 1

ISO6B/G2

ISO6B Generation 2

EPC Class 1 Gen 2 (default)

EPCglobal Class 1 Gen 2

This setting is equivalent to the TAGTYPE BRI attribute.

Supported Tag Type (Gen 2) Enables or disables Gen 2 tag support for RFID operations. Choose EPC Class 1 Gen 2 (default) to enable Gen 2 support, or None to disable Gen 2 support.

Dense Reader Mode Check this check box to enable Dense Reader mode, which is only supported by EPC Class 1 Gen 2 tags. When dense reader mode is enabled, these tags respond with Miller Sub carrier encoded data instead of FM0 encoded data. This setting is equivalent to the DENSEREADERMODE BRI attribute.

44

IF30 Fixed Reader User’s Manual

Page 57

Chapter 3, Creating and Using RFID Applications

LBT Channel Sets the default transmit channel of the available ETSI 302-208 channels. When you enable LBT scanning, the channel scan sequence starts with this LBT channel. When LBT scanning is disabled, (as in the 4 channel mode) the LBT channel is the only channel used. The range for 10 channel mode is 4 to 13. The default for 10 channel mode is 8, and for 4 channel mode the default is 7. The valid values in 4 channel mode are 4, 7, 10, 13. This setting is equivalent to the LBTCHANNEL BRI attribute.

LBT Scan Enable LBT scanning is enabled, by default in ETSI 10 Channel mode in accordance with 302-208. Note: LBT scanning is permanently disabled in ETSI 4 channel mode in accordance with 302-208 v1.2.1. When LBT scanning is enabled, the algorithm scans the available ETSI 302-208 channels for a free transmit channel. In continuous read mode, the scan sequence begins with the channel specified by LBTCHANNEL and every third channel is checked (for example, 8, 11, 4, 7, 10, 13, 6, 9, 12, 5) until a free channel is found. If a free channel is not found, LBT repeats the scan sequence. In single-shot read mode, LBT scanning goes through all available channels at once. If no free channel is found, the reader will report “NOTAG” and abort the inventory operation. When LBT scanning is disabled, the IF30 does not scan for a free transmit channel, and the transmit channel is set by the LBTCHANNEL BRI attribute. This setting is equivalent to the LBTSCANENABLE BRI attribute.

Field Separator Sets the space character to be used for separating fields in tag data. Choose either space ( ) or comma (,). Default is space. This setting is equivalent to the FIELDSEP BRI attribute.

IF30 Fixed Reader User’s Manual

45

Page 58

Chapter 3, Creating and Using RFID Applications

ID Report Enables or disables tag ID reporting after a Read, Write, or Lock command is executed: •

For ISO tags, the tag identifier corresponds to TAGID.

•

For EPC tags, the tag identifier corresponds to EPCID.

Check the check box to enable tag ID reporting. This setting is equivalent to the IDREPORT BRI attribute.

No Tag Report Enables or disables a NOTAG message, which is sent when no tags are found during execution of a Read, Write, or Lock command. Check the check box to enable the message. This setting is equivalent to the NOTAGRPT BRI attribute, and is enabled by default.

Timeout Configuration Mode Enables a timeout mode. Instead of specifying the number of antenna or ID tries, you specify a timeout value. If the IF30 does not find any tags after an antenna or ID try, the reader waits for the specified time before starting the next antenna or ID try. This setting is equivalent to the TIMEOUTMODE BRI attribute, and is disabled by default. To enable Timeout Configuration Mode 1 Check the check box and then click Save Changes. The screen refreshes. The Antenna Tries setting is replaced by Antenna Timeout, and the ID Tries setting is replaced by the ID Timeout. 2 Specify the value (in ms) for the timeout in the entry fields and then click Save Changes.

ID Tries Sets the maximum number of times the reader executes the identify algorithm before a response is returned to a Read or Write command. In practice, this is the number of times a tag ID attempt is made for each antenna being used. Valid range is 1 to 254. Default is 3. This setting is equivalent to the IDTRIES BRI attribute. 46

IF30 Fixed Reader User’s Manual

Page 59

Chapter 3, Creating and Using RFID Applications

Antenna Tries Sets the maximum number of ID Tries that the reader executes per antenna. Valid range is 1 (default) to 254. This setting is equivalent to the ANTTRIES BRI attribute.

Read Tries Sets the maximum number of times the read algorithm is executed before a response is returned to a Read command. In practice, this is the number of times an identified tag will be read until the read is successful. Valid range is 1 (default) to 254. This setting is equivalent to the RDTRIES BRI attribute.

Write Tries Sets the maximum number of times the write algorithm is executed before a response is returned to a Write command. In practice, this is the number of times an identified tag will be written until the write is successful. Valid range is 1 to 254. The default is 3. This setting is equivalent to the WRTRIES BRI attribute.

Initialization Tries Sets the maximum number of times the reader attempts to initialize a tag. Valid range is 1 (default) to 254. This setting is equivalent to the INITTRIES BRI attribute.

Lock Tries Sets the maximum number of times the lock algorithm is executed before a response is returned to a Lock command. Valid range is 1 to 254. The default is 3. This setting is equivalent to the LOCKTRIES BRI attribute.

Select Tries (Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group select is attempted. A group select is the command that starts the identity process. Valid range is 1 (default) to 254. This setting is equivalent to the SELTRIES BRI attribute. IF30 Fixed Reader User’s Manual

47

Page 60

Chapter 3, Creating and Using RFID Applications

Unselect Tries (Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group unselects is attempted. Valid range is 1 (default) to 254. This setting is equivalent to the UNSELTRIES BRI attribute.

Initial Queue (EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter value used by the Query command. Valid range is 0 to 15. The default is 4. If you know there is only one tag in the field, set this attribute to 0 for best performance. This setting is equivalent to the INITIALQ BRI attribute.

Session (EPCglobal Class 1 Gen 2 tags only) Sets the command session parameter to the corresponding EPCglobal Class 1 Gen 2 air protocol command (default is QueryAdjust). This setting is equivalent to the SESSION BRI attribute. For more information on this setting, see the EPCglobal Class 1 Gen 2 documentation.

Field Strength Sets the RF power level (measured as a percentage of maximum power) for all antennas. Valid range is 1 to 100 (default). Use this setting to antennuate the antenna field strength. In some situations, full output power can cause unnecessary interference. For example, if the tag is close to the antenna, full output power might overload the tag and cause unreliable behavior. This setting is equivalent to the FIELDSTRENGTH BRI attribute.

Enable Antenna Port n Enables or disables the antenna connected to antenna port n. Check the check box to enable that antenna. Antenna Port 1 is enabled by default. If more than one antenna is enabled, the antennas always fire in sequence numerically (1, 2, 3, 4). To change this sequence, you need to set the ANTS BRI attribute. For more information, see the BRI programmer’s reference manual. 48

IF30 Fixed Reader User’s Manual

Page 61

Chapter 3, Creating and Using RFID Applications

Configuring the Data Collection Engine The IF30 data collection engine (DCE) handles communication between your application and the RFID module. It allows up to 10 applications to use the same reader simultaneously. When your application is communicating with the DCE, the blue Intermec Ready-to-Work Indicator on the IF30 front panel turns on and stays on. For help, see “Learning About the Intermec Ready-toWork Indicator” on page 7. You can configure many settings for the DCE. For help, see the next procedure. To configure DCE settings 1 From the menu, click RFID Module > DCE Configuration. The DCE Configuration screen appears.

2 Change DCE settings as needed. For help, see the next table. 3 Click Submit Changes to save your changes. To activate your changes, from the menu bar click Save/Discard Changes, and

IF30 Fixed Reader User’s Manual

49

Page 62

Chapter 3, Creating and Using RFID Applications then click Save Changes and Reboot. For help, see “Saving Configuration Changes” on page 16. DCE Configuration Parameter Descriptions Parameter

Description

Allows External Enables/disables external TCP connections to the DCE BRI BRI server. Connections BRI TCP Port

Specifies the TCP port used for incoming BRI connections to the DCE. This port must be unique for all TCP services running on the IF30. Valid range is 0 to 65535. Default is 2189.

BRI Heartbeat

Enables/disables asynchronous heartbeat event (EVT: HEARTBEAT BRI STRING). When enabled, the IF30 sends the heartbeat event every 30 seconds, enhancing the IF30’s ability to detect TCP sessions that were not closed cleanly.

Trigger Management

Enables DCE control of trigger states. When Trigger Management is enabled, the DCE manages the triggers so your application never needs to issue a TRIGGERREADY command. When Trigger Management is disabled, your application must manage issuance of the TRIGGERREADY command.

Allow External Enables/disables external TCP connections to the DCE EPC EPC server. When this box is not checked, the DCE accepts Connections EPC connections only from applications residing on the IF30. EPC TCP Port

Specifies the TCP port used for incoming EPC Reader Protocol connections to the DCE. This port number must be unique for all TCP services running on the IF30. Valid ranges is 0 to 65535. Default is 4684.

Enable Logging Enables/disables logging of commands sent and received through the DCE.

Viewing the DCE Events Log If you enable DCE logging, you can see a list of commands sent and received through the DCE. You can save the logfile as a .txt file. To enable DCE logging and view the logfile 1 From the menu, click RFID Module > DCE Configuration. the DCE Configuration screen appears. 50

IF30 Fixed Reader User’s Manual

Page 63

Chapter 3, Creating and Using RFID Applications

2 Check the Enable Logging check box. 3 Click Submit Changes to save your changes. To activate your changes, from the menu bar click Save/Discard Changes, and then click Save Changes and Reboot. For help, see “Saving Configuration Changes” on page 16. 4 After the IF30 reboots, click Refresh in the browser menu. The login screen appears. 5 Enter your user name and password, and then click Login. The TCP/IP Settings screen appears. 6 From the menu, click RFID Module > DCE Configuration. The DCE configuration screen appears. 7 Click Display Log, the DCE Configuration/Display Log screen appears with a list of command events.

8 To save the log file, click Download Logfile and then choose File > Save As. Follow the prompts to save the log file to your desktop PC.

IF30 Fixed Reader User’s Manual

51

Page 64

Chapter 3, Creating and Using RFID Applications

DCE Log Command Event Descriptions Event Name

Description

Time/Date

Time and date of the event.

Connection

TCP port of the event. 0 indicates a serial connection.

Type

Message type of the event, generally indicating which system sent the message: 1 - Message from the RFID module to the DCE. 2 - Message from the DCE to the RFID Module. 3 - Message from the application to the DCE. 4 - Messages from the DCE to the application. Types 1 and 2 are suffixed by the message checksum value used by the reader module to detect errors.

Message

Text of the message, including responses.

Viewing DCE Statistics You can use the web browser interface to view a list of DCE statistics. To view DCE statistics 1 From the menu, click RFID Module > DCE Configuration. The DCE Configuration screen appears. 2 Click Display > Statistics. The DCE Configuration/Display Statistics screen appears with a list of DCE statistics.

52

IF30 Fixed Reader User’s Manual

Page 65

Chapter 3, Creating and Using RFID Applications

3 To save the list, click Download Statistics File and then choose File > Save As in the browser menu. Follow the prompts to save the list to your desktop PC as a .txt file.

IF30 Fixed Reader User’s Manual

53

Page 66

Chapter 3, Creating and Using RFID Applications

54

IF30 Fixed Reader User’s Manual