Page 83

5 Using the IF30 GPIO Interfaces

This chapter explains how to access the IF30 general purpose input/output (GPIO) interfaces and how to connect industrial controls such as motion sensors or indicator lamps to the IF30 Fixed Reader. This chapter includes these topics: •

About the GPIO Interfaces

•

Accessing the GPIO Interfaces

•

Using the Input Interfaces

•

Using the Output Interfaces

•

Using the Power Interface

71

Page 84

Chapter 5, Using the IF30 GPIO Interfaces

About the GPIO Interfaces The IF30 has four general purpose input and output (GPIO) interfaces. You connect external controls such as motion sensors or indicator lamps to the GPIO interfaces, which can then trigger IF30 operations. Each interface is electrically isolated from the IF30 and designed for low voltage DC loads. The IF30 can also supply 12 VDC at 0.5 A to external devices. How the inputs and outputs are used depends on the RFID application software being used in the system. You need to coordinate input and output control wiring with the software developer.

Accessing the GPIO Interfaces You can access the GPIO interfaces through the control port on the front panel of the IF30. The control port uses a standard 25-pin serial cable. For port pin assignments, see “Port Pin Assignments” on page 84. You can also use the GPIO Terminal Block accessory to connect devices to the IF30 GPIO interfaces. The block provides access to the IF30 GPIO interfaces via standard screw terminals.

GPIO Terminal Block Accessory

For more information on the terminal block, contact your local Intermec distributor.

72

IF30 Fixed Reader User’s Manual

Page 85

Chapter 5, Using the IF30 GPIO Interfaces

Using the Input Interfaces Each of the four inputs is compatible with input signals of 10 to 48 VDC. Both of the high and low signal contacts are exposed and isolated to 1500 V. Input impedance is 1.8K minimum. GPIO Signal Input Descriptions Signal

Description

Min.

Typical

Max.

Vin (High) High input voltage 10 V

24 V

48 V

Vin (Low)

0V

1V

Low input voltage -1 V

In a typical application, the IF30 senses input from an external control like a switch and then starts a tag read operation. There are three basic ways to connect input controls to the IF30 input interfaces: •

Supply the input interface with power from the IF30.

•

Isolate the IF30 from the input power source.

•

Use an open collector solid state drive from a remote device to control the inputs.

IF30 Powered Input This is the simplest way to connect a control to an IF30 input interface. If the external control device is a switch, you can connect one side of the switch to an IF30 +Input pin, and the other side of the switch to one of the +12 VDC sources, then ground the corresponding -Input pin.

IF30 Fixed Reader User’s Manual

73

Page 86

Chapter 5, Using the IF30 GPIO Interfaces +12 V +Input External input switch -Input Ground

IF30 Powered Input

Isolated Input Interface This method is used to minimize noise induced by distance or grounding. The isolated input avoids induced noise by referencing a remote input to chassis return of the IF30. The illustration below shows how to wire in this method. External input switch +Input

- +

-Input

10 -48 VDC Twisted pair

Isolated Input Interface

Open Collector Interface The input can be connected to an open collector interface of an external device. This implies that the grounds are tied together for two systems. The common ground can be a source of noise, so you should follow good grounding practices for both the IF30 and the input device. In this situation, the IF30 provides power to the pull-up resistor for the open collector. Connect the +Input pin to the +12 VDC source as shown in the next illustration. 74

IF30 Fixed Reader User’s Manual

Page 87

Chapter 5, Using the IF30 GPIO Interfaces +12 V +Input

-Input Ground

Open Collector Interface

Using the Output Interfaces Each IF30 output interface is optically isolated, polarized, and rated for 5 to 48 VDC at 0.25 A. All IF30 outputs include internal thermal fuses that trip if the load exceeds 0.25 A, and the fuses are selfrecovering once the excessive load is removed. The high and low contacts are exposed and isolated from the ground. Transient suppression limits output voltage spikes to 65 VDC. GPIO Output Specifications Signal

Description

Min.

Typical

Max.

Leakage current (High)

Switch output, high leakage current

0 mA

1 mA

10 mA

1V

1.5 V

0V Vsat (Low) Switch output on, saturation voltage with .25A load

Since the outputs are optically isolated, each of the outputs can be configured to switch the high or low side of the load. You can power the load directly from the IF30 or from an external power supply. In a typical application, the outputs control indicator lamps that signal good reads or errors. These are the basic methods for connecting external devices to the GPIO outputs: •

Switching the high side, with the load powered by the IF30.

•

Switching the low side, with the load powered by the IF30.

IF30 Fixed Reader User’s Manual

75

Page 88

Chapter 5, Using the IF30 GPIO Interfaces

•

Switching the high side, with the load powered externally.

•

Driving a DC relay that controls an AC load.

Switching the High Side Using IF30 Power In this example, an external indicator lamp with a 0.25A maximum current is connected to the -Output and Ground pins, and the corresponding +Output pin is connected to the +12 VDC source. +12 V +Output External indicator lamp 0.25A maximum -Output Ground

Switching the High Side

Switching the Low Side Using IF30 Power For low side switching applications, the lamp is routed to all the lamps in common and the low side of the load is routed to the switch. In this method, connect the external indicator lamp to the +Output and +12 VDC pins, and short the corresponding -Output pin to ground as shown. External indicator lamp 0.25 A maximum +12 V +Output

-Output Ground

Switching the Low Side

76

IF30 Fixed Reader User’s Manual

Page 89

Chapter 5, Using the IF30 GPIO Interfaces

Switching the High Side Using External Power To use external power (5 to 48 VDC) to switch the high side, connect the Ground pin to the ground system of the external power supply, and connect the positive side of the external supply to the +Output pin. The external indicator lamp is connected to the corresponding Output and Ground pins as shown below. + External power 5-48 VDC +Output -Output Ground External indicator lamp

Switching the High Side With External Power

IF30 Fixed Reader User’s Manual

77

Page 90

Chapter 5, Using the IF30 GPIO Interfaces

Driving a DC Relay to Control an AC Load While the IF30 outputs are designed to switch DC loads, they can drive relays that control AC loads. The illustration on the next page shows how to connect such a system to an IF30 output. AC motor

+12 V +Output

-Output

120 -230 VAC

Ground External relay

Driving a DC Relay: The external relay provides dry contacts for controlling the AC motor.

Note: In many installations, the relay and AC wiring must be placed in an enclosure that meets local fire code regulations.

Using the Power Interface The IF30 GPIO interface provides 12 VDC at 0.5 A for powering external inputs and loads, eliminating the need for an external DC supply and simplifying the system installation. The GPIO interface power has an internal thermal fuse that trips if the load exceeds 0. 5A. The fuse is self-recovering once excessive load is removed. The total load on the GPIO interface power must stay within the 0.5 A limit. When you design a system that uses the GPIO interface power, be sure to complete a power budget assessment to ensure that the supply is adequate for the system.

78

IF30 Fixed Reader User’s Manual

Page 91

Chapter 5, Using the IF30 GPIO Interfaces

If your system needs more than +12 VDC at 0.5 A, you can connect to an external power supply to the +12 V and Ground pins. The external supply powers the external loads, and that power will be available at all +12 V pins on the control port.

IF30 Fixed Reader User’s Manual

79

Page 92

Chapter 5, Using the IF30 GPIO Interfaces

80

IF30 Fixed Reader User’s Manual