Page 71
Setting Up the DCS 300
2
Deleting User Files 1. From the main menu sidebar buttons, choose File Handling. The File Handling dialog box appears. 2. In the File Handling list box, select Delete User Files and then choose Start. The Delete User Files dialog box appears.
3. In the root directory list box (\), add all the files that you want to delete to the Selected Files list box. a. Select the file name. b. Choose Select. The file name appears in the Selected Files list box. 4. In the Selected Files list box, remove any the files that you do not want to delete. a. Select the file name. b. Choose Remove. The file name is removed from the Selected Files list box. 5. Choose Delete Files. A message box appears confirming that you want to delete the files. 6. Choose Delete. The server deletes the user files you selected.
2-19
Page 72
DCS 300 User’s Manual
Using the DCS 300 To use the DCS 300, you need to know how to start and stop data collection and shut down the server. Caution Always choose Shutdown DCS 300 before rebooting or turning off the server. If you do not shut down the server properly, you may lose data or damage files on the server. Conseil Choisissez toujours le bouton Shutdown DCS 300 dans l’encadré avant de réamorcer ou de fermer l’unité de contrôle. Si vous ne fermez pas correctement l’unité de contrôle, vous risquez de perdre des données ou d’endommager les fichiers sur l’unité de contrôle.
Starting Data Collection 1. From the main menu sidebar buttons, choose Save and Activate. A message box appears confirming that you want to save your changes and activate the configuration. 2. Choose Activate. A message box may appear informing you that the server needs to reboot and that you need to choose OK. Or, a message box may appear informing you that your activate is successful. 3. From the main menu sidebar buttons, choose Start Data Collection. The Start Data Collection message box appears. 4. Choose Start to start data collection. The title bar shows “Data Collection: Started.”
Stopping Data Collection You may need to stop data collection on the DCS 300 to update its configuration file. When you stop data collection, all data collection activities are stopped, but any external Intermec controllers continue polling and buffering data. Devices using programs that require a response directly from a destination (interactive mode) also stop until the server is started again. To stop data collection 1. From the main menu sidebar buttons, choose Stop Data Collection. The Stop Data Collection message box appears. 2. Choose Stop to stop data collection. The title bar shows “Data Collection: Stopped.”
2-20
Page 73
Setting Up the DCS 300
2
Shutting Down the DCS 300 You may need to power off the DCS 300 for maintenance or relocation. The server needs to perform a series of shutdown activities, which may take up to five minutes to ensure that no system files or data are lost. To turn off the DCS 300 1. From the main menu sidebar buttons, choose Shutdown DCS 300. The Shutdown DCS 300 message box appears. 2. Check or clear the Save and activate changes check box depending on if you want to save and activate any changes you have made to the configuration. Note: If you have saved your changes without activating them (only [Activate] appears in the title bar) this check box will be grayed. The server will automatically activate your changes before it shuts down. 3. Choose Shutdown to shut down the server. The server needs to perform a series of shutdown activities, which may take up to five minutes. A message box appears letting you know when you can safely turn off the server.
2-21
Page 74
DCS 300 User’s Manual
Accessing a Command Prompt While maintaining or configuring the DCS 300, you may find your task is easier by accessing a command prompt. To access a command prompt 1. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 2. In the System Maintenance list box, select DCS 300 Command Prompt and then choose Start. The Command Prompt Password dialog box appears.
3. In the Password field, type: INTERMEC
4. Choose OK. The DCS 300 Command Prompt window appears. To close the Command Prompt window 1. Choose the box in the upper left corner of the window. A drop-down menu appears. 2. Choose Close to return to the main menu.
2-22
Page 75
3 Connecting to an Ethernet/Token Ring Network
Page 76
DCS 300 User’s Manual
Page 77
Connecting to an Ethernet/Token Ring Network
3
This chapter describes how to install the DCS 300 in your Ethernet or token ring network and how to configure the network adapter card.
Chapter Checklist Done?
‰ ‰ ‰
Task
Page
Install the server in the Ethernet network.
3-4
Install the server in the token ring network.
3-5
Use the GUI to configure each Ethernet and token ring card for TCP/IP.
3-6
Or,
‰ ‰
Use the GUI to configure each Ethernet and token ring card for IEEE 802.2.
3-12
Save your run-time configuration.
3-13
If you already understand and have performed these tasks, either connect the DCS 300 to another host or set up the host environment as described in these chapters: •
Chapter 4, “Connecting to a Coaxial/Twinaxial Network”
•
Chapter 5, “Connecting to an SDLC Network”
•
Chapter 6, “Connecting to the Intermec RF Network”
•
Chapter 7, “Connecting to the 9180 and the Intermec CrossBar Network”
3-3
Page 78
DCS 300 User’s Manual
Installing the DCS 300 in an Ethernet Network There are two types of Ethernet network adapter cards you can have in your DCS 300: a 10 Mbps card or a 10/100 Mbps card. The parameters you set are the same for both cards. For information about upgrading to a 10/100 Mbps card (Intermec Part No. 066413), contact your local Intermec representative. Before you can configure the DCS 300, you need to install it in your network.
Equipment •
An Ethernet connection where you can connect the server.
•
A cable to connect the server to the connection. You can use any of these types of cables: UTP for 10BaseT, RG-58 coax for 10Base2, 50-ohm coax for 10Base5.
Note: The default configuration for the Ethernet card is 10BaseT or 100BaseTX. Contact your local Intermec representative if you need to use 10Base2 or 10Base5. To install the server 10 Mbps
100 Mbps
1. Locate the slot that contains the Ethernet card(s) on the rear panel of your server. Refer to the figures on the left. 2. Insert one end of the cable into the appropriate Ethernet port on the card and the other end into the Ethernet connection. Note: If you are using 10Base2, make sure that you connect the cable to both the port and the Ethernet connection before turning on the server.
0300U.019
3-4
0300U.020
Page 79
Connecting to an Ethernet/Token Ring Network
3
Installing the DCS 300 in a Token Ring Network Before you can configure the DCS 300, you need to install it in your network.
Equipment •
A token ring connection where you can connect the server.
•
A cable to connect the server to the connection. Your token ring card comes with an RJ-45 to STP cable.
Note: The default ring speed for the token ring card is 16 Mbps. Contact your local Intermec representative if you need to set the ring speed to 4 Mbps. To install the server Token ring
1. Locate the slot that contains the token ring card on the rear panel of your server. The connector on the card looks like the figure on the left. 2. Insert one end of the cable in the token ring port on the card and the other end in the token ring connection.
0300U.021
3-5
Page 80
DCS 300 User’s Manual
Configuring the Network Adapter Card for TCP/IP After you install the DCS 300, you need to turn it on and configure its network adapter cards. Ethernet and token ring support both TCP/IP and IEEE 802.2 protocols. To configure the card for TCP/IP, either use a Dynamic Host Configuration Protocol (DHCP) server to provide the server TCP/IP information or enter the TCP/IP configuration manually. If you do not enter an IP address or subnet mask and you do not check the Use DHCP check box, TCP/IP communications are disabled. Use a DHCP server to provide the server’s IP information You can configure the DCS 300 to be a DHCP client in a network that uses a DHCP server. The DHCP server can provide the DCS 300 with an IP address assignment and other basic IP configuration characteristics, such as the subnet mask, the router IP address, and the DNS server address. Note: The DCS 300 supports only one network adapter card that is using DHCP. If you have a backup DCS 300 that is also configured as a DHCP client, you do not need to enter its IP address in each of your UDP Plus devices when it comes online. If you leave the backup DCS 300 online, you can perform pseudo load-balancing on your UDP Plus network. You need to use these bar codes to enable DHCP on each UDP Plus device Enable DHCP
! (+& *$+NI0*
Disable DHCP
! *$+NI1*
Note: To use DHCP across routers in your network, the routers must have the DHCP relay agent configured and enabled. For help, see your router user’s manual. Enter the server’s IP information manually From your network administrator, obtain a valid IP v4 address for each Ethernet or token ring card. You may also need to know the server’s local host name and the subnet mask. If you have two or more cards communicating using TCP/IP, each card must be on a different subnet. If you need to set up routing tables for the TCP/IP configuration, you also need the IP addresses of the route destinations and of the routers. To configure the network adapter card 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Local Network Adapter. Five buttons for different network adapter card types appear. 3. Choose the type of network adapter card (Ethernet or token ring) that you are configuring. The Advanced Protocol Configuration dialog box appears.
3-6