Page 51

Learning About the DCS 300

1

Note: If an application sends a Inter system transaction instead of an acknowledgment to the message handler, the message handler retransmits the last transaction it sent to that application.

Nonactive Applications A nonactive application has failed to complete the handshake with the DCS 300 for a transaction. An application becomes nonactive in these two situations: •

If the Hot Standby timeout expires before the server received an ACK from the application, the server places the application in a nonactive state. Also, the server writes all subsequent transactions for the application in a Hot Standby file.

•

If the number of transactions in the application’s AUX_Q reaches its limit, the server places the application in a nonactive state. Also, the server writes the contents of AUX_Q and all new transactions for the application into the Hot Standby file.

Sending Hot Standby Messages When the server receives a transaction for a nonactive application, it can send a userdefined response to the device that sent the transacaction. This user-defined response is the Hot Standby message. You can use the GUI to configure a Hot Standby message for each transaction ID. The Hot Standby message can serve as a positive response to a device by indicating that the transaction was saved on disk. Note: If the server does not recognize the transaction ID, the server sends a bad ID response to the source of the invalid transaction. You configure this bad transaction ID response in the System Parameters dialog box. Also, if the application receives a transaction is from a bar code reader that is operating in computer response required mode (CRRM), the reader remains locked until a response is received or the reader times out. The server should reply with the Hot Standby message when it cannot deliver a transaction to the application. If the Hot Standby message field is empty, the server sends nothing to the device when it saves a transaction on disk. It becomes the application’s responsibility to return a response to a device when it receives the transaction. In some cases, a response may not even be required, such as when the application is receiving status transactions from printers. Because transactions can have multiple routes, the server appends a comma to the end of a Hot Standby message followed by the name of the destination where the Hot Standby response is being sent.

1-29

Page 52

DCS 300 User’s Manual

For example, you can define a transaction ID (TRXID1) that gets routed to three destinations (selftest, writeit, and batchit) and has the Hot Standby message, “Data saved on disk.” When the server receives the TRXID1 transaction from a device, the message handler sends a copy of the transaction to each of the defined destinations and starts a Hot Standby timer for each one. If writeit and batchit do not acknowledge the transaction before they go nonactive, the message handler sends these strings to the device that was the source the transaction: Data saved on disk, writeit Data saved on disk, batchit

Changing From Nonactive to Active Status When an application is nonactive, only two events allow it to become active: •

The application sends an ACK transaction for the most recently delivered transaction. In this case, the next transaction waiting is sent.

•

The application sends a Inter system transaction. In this case, if the last transaction sent to the application was not acknowledged, sending Inter causes the transaction to be retransmitted.

Active Recovery Mode Before entering a fully active state, the application goes through a recovery period, called Active Recovery mode. The DCS 300 takes transactions from the application’s Hot Standby file and sends them in chronological (FIFO) order to the application. The application must acknowledge each transaction just as if it were active. From the application’s point of view, it is an active application. To determine if the application is in Active Recovery mode, examine the batch flag in the transaction header. The batch flag is set to B on all transactions stored in the Hot Standby file prior to being forwarded to the application channel. New transactions sent to an application in an Active Recovery mode are still sent to the Hot Standby file. From the device’s point of view, the application is in Hot Standby mode. If the application is designed correctly for the data collection system, it should eventually be able to take delivery of all transactions in the Hot Standby file and resume interactivity with the device. At this point, the new transactions are no longer sent to the Hot Standby file. They are stored in AUX_Q until the application acknowledges or confirms responsibility for the transaction. After the acknowledgment or confirmation, the application is then active. Note: Data in an ACK transaction is ignored and not sent to the originator of the transaction if the transaction came from the Hot Standby file.

1-30

Page 53

2 Setting Up the DCS 300

Page 54

DCS 300 User’s Manual

Page 55

Setting Up the DCS 300

2

This chapter explains how to set up the hardware for your DCS 300, configure the system parameters, and perform basic maintenance on your files.

Chapter Checklist Done?

‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰ ‰

Task

Page

Plug in the power cord.

2-4

Plug in the keyboard.

2-5

Plug in the mouse.

2-6

Connect the monitor.

2-7

Connect the uninterruptable power supply.

2-8

Connect the modem.

2-10

Set the system parameters.

2-12

Understand the configuration files and how to restore your default configuration.

2-14

Understand how to back up and restore the system and user files on your DCS 300.

2-15

Understand how to start data collection, stop data collection, and shut down the DCS 300.

2-20

If you already understand and have performed these tasks, connect the server to your Intermec data collection network as described in these chapters: •

Chapter 3, “Connecting to the Intermec RF Network”

•

Chapter 4, “Connecting to the 9180 and the Intermec CrossBar Network”

2-3

Page 56

DCS 300 User’s Manual

Plugging In the Power Cord You need to attach the power cord before you can run the DCS 300. However, you may want to plug the power cord into a surge protector or an uninterruptable power supply (UPS). Intermec requires that you use a surge protector in locations that use 115 VAC. Intermec recommends that you use a UPS in locations that have wide variations in AC power. For help, see “Connecting an Uninterruptable Power Supply” later in this chapter.

WARNING

Warning Before connecting the power cord, make sure that the server power switch is off. Failure to comply could result in injury due to electrical shock. Avertissement Avant de faire la connexion de la source de courant, assurez-vous que le commutateur soit “Off.” Faute de quoi vous risquez une blessure comme un choc électrique.

Equipment •

Power cord, 110V U.S. cord (standard) Or, Power cord, 240V (Intermec Part No. 586266) Power cord, 250V (Intermec Part No. 586267)

•

Surge protector

To connect the power cord 1. Locate the AC in port on the rear panel of the server. 2. Insert the power cord’s 3-pin connector into the AC in port. 3. Intermec recommends that you use a surge protector. Plug the surge protector into the AC power outlet. 4. Plug the power cord into an AC power outlet or surge protector.

2-4

Page 57

Setting Up the DCS 300

2

Plugging In the Keyboard You need to use the keyboard to enter information when using the GUI to configure the DCS 300.

Equipment •

Keyboard (standard)

To plug in the keyboard 1. Locate the keyboard port on the rear panel of the server. 2. Insert the keyboard connector into the keyboard port.

0300U.008

2-5

Page 58

DCS 300 User’s Manual

Plugging In the Mouse The mouse makes it easier for you to move around in the GUI when configuring the DCS 300. Note: You must have the mouse plugged into the server whenever you boot the server.

Equipment •

Mouse (standard)

To plug in the mouse 1. Locate the mouse port on the rear panel of the server. 2. Insert the mouse connector into the mouse port.

0300U.009

2-6

Page 59

Setting Up the DCS 300

2

Connecting the Monitor Equipment •

Monitor with cable and power cord (not provided)

To connect the monitor 1. Locate the video port on the rear panel of the server. 2. Insert one end of the monitor cable into the video port. 3. Insert one end of the power cord into the monitor and the other end into an AC power outlet.

0300U.010

To AC power

2-7

Page 60

DCS 300 User’s Manual

Connecting an Uninterruptable Power Supply Intermec strongly recommends that you connect an uninterruptable power supply (UPS) to your DCS 300. In case of a power failure, the UPS provides enough backup power to allow the server to properly shut down and minimize the loss of data. If you experience a power failure after installing a UPS, these events will occur: •

If power returns within 45 seconds, no error message is logged and no message appears on the monitor.

•

If power does not return within 45 seconds, an error message is logged and this message appears on the monitor. Power failure. UPS is running on battery power. Stopping data collection to preserve data integrity. DCS 300 shutdown will occur in approx 5 minutes.

When data collection is stopped, the server tries to shut down. Five minutes after the error message is logged, the UPS cuts off power to the server. You can configure the server to automatically restart data collection when power returns. For help, see “Setting the System Parameters” later in this chapter.

Equipment •

Uninterruptable power supply, U.S. and Canada (Intermec Part No. 589082). Uninterruptable power supply, International (Intermec Part No. 589079)

•

Cable for auto-restoration (Intermec Part No. 589157)

To connect a UPS 1. Make sure the power is off. The power LED should be off. 2. Insert the server power cord 3-pin connector into the AC in port. 3. Plug the other end of the power cord into the UPS. 4. (Optional) Intermec recommends that you use a surge protector. Plug the power cord of the UPS into the surge protector or an AC power outlet. 5. Insert one end of the serial cable into the serial port on the UPS. 6. Insert the other end of the serial cable into a COM port on the server. 7. Press the power button on the server. The power LED turns on. The main menu appears. 8. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears.

2-8