Page 451

DCS 300 System Manual Addendum

To configure an IP host 1. From the main menu, choose Terminal Emulation. 2. Choose Host Connection and then choose IP Host. The IP Terminal Emulation Configuration dialog box appears. The list box contains the host names that you have configured. Hosts that have ports are prefixed by a + (plus) sign or a - (minus) sign. Double-click on a host name with a + sign and the ports that have been configured for that host will appear underneath it. Double-click on a host name with a - sign and the ports for that host will disappear.

3. Choose Add Host, Add Port, Edit, or Delete. You must be able to select a host before you choose to add a port, edit a host, or delete a host. That is, you must have already added at least one host. If you choose Add Host, the TCP/IP Host Connection dialog box appears. For help, see “Configuring a Telnet Host” in Chapter 8 of the DCS 300 System Manual. If you choose Add Port, the Port Configuration dialog box appears. For help, see “Adding an IP Port” in the next section.

17

Page 452

DCS 300 System Manual Addendum

Adding an IP Port This section is new. The Port Configuration dialog box is new. Note: When you add an IP host, a default port (Telnet, port number 23) is automatically added. To add an IP port •

From the IP Terminal Emulation Configuration dialog box, choose Add Port. The Port Configuration dialog box appears.

Field

Description

Value

Default

Port name

The name that identifies this port for this host. The name must be unique for this host.

1 to 8 alphanumeric characters

None

Port number

The number of the port that you are configuring for this host. The number must be unique for this host.

1 to 65535

None

Type

These option buttons identify the type of port that you are configuring.

Telnet, Native

Native

Send ID (Native only)

This check box determines if the terminal session name, RF host stack number, and the terminal number are sent to the host.

Check, Clear

Clear

18

Page 453

DCS 300 System Manual Addendum

Configuring TE Links This section amends pages 8-23 and 8-24. The Terminal Emulation Links dialog box lets you change links for individual terminal sessions. These explicit links override the host name that is defined on the terminal and the default host link that you defined when you configured the downline connection point. You can only link Native host ports to WTP devices. The Linked Terminal Sessions box and the Unlinked Device/State box let you select multiple objects by • clicking and dragging to select several sequential objects.

• selecting one object and then holding down the Shift key and selecting another object. You now have selected all sequential objects from the first clicked object to the last one.

• selecting one object and then holding down the Ctrl key and selecting another object. You now have selected two non-sequential objects.

Linked Terminal Sessions box This list box contains the terminal sessions and devices that are explicitly linked to a host. It contains a new column that identifies the port name of the Telnet or Native host. Hosts by Terminal Type list box This list box contains the host types (5250, Native, etc.) that you have configured. Telnet hosts and Native hosts are prefixed by a + (plus) sign or a - (minus) sign. You can double-click on a host with a + sign and the ports that have been configured for that host will appear underneath it. You can double-click on a host with a - sign and the ports for that host will disappear. Unlinked Device/State list box This list box contains a list of terminal sessions and devices that have not been linked to a host. You can select multiple terminal sessions and devices in this box and link them to a host or apply a state to them.

19

Page 454 read from a scan by OCR; it may hold reading errors

DCS 300 System Manual Addendum

Terminal Emulation Links Dialog Box e= Terminal Emulation Links

Set device terminal sessions to be linked to a configured host, to rely on the default host, to be prompted for the host, or to be disabled.

-Linked Terminal Sessions dH HAUL.

Host Type Port Name Device NAU ba] Unlink... Link fe Hest | _Detault/ Supplied) Prompt for Host| Disable Session | Hosts by Terminal type Unlinked Device State Default HOSTO002 Default HOSTO003 Default »| |HosTo004 Default |~|

|_Close | Help

20

Page 455

DCS 300 System Manual Addendum

Creating Terminal Sessions This section amends page 10-7. The 5250, 3270, VT/ANSI buttons have been renamed to 5250 SNA, 3270 SNA, and Telnet. You can use these sessions to access the host from the DCS 300 or you can use them for screen mapping sessions. 5250 SNA button This button lets you configure 5250 SNA terminal sessions. 3270 SNA button This button lets you configure 3270 SNA terminal sessions. Telnet button This button lets you configure Telnet terminal sessions. In the Mode field, you can choose VT100, VT220, VT320, ANSI, TN3270, or TN5250. There is a limit to the number of terminal sessions that the DCS 300 can support. The total number of sessions is the sum of all of the terminal session types. You can have 100 VT100 sessions and 128 VT220 sessions, but you cannot have 228 VT100 sessions and 228 VT320 sessions.

Terminal Session Type

Total Number of Sessions

VT100, VT220, VT320, ANSI

228

TN3270, TN5250, 5250 SNA, 3270 SNA

26

Note: You can create a maximum of 15 5250 SNA terminal sessions.

To create a terminal session 1. From the main menu, choose Terminal Sessions. 2. Choose Host Connection. The Terminal Session List dialog box appears.

21

Page 456

DCS 300 System Manual Addendum

3. Choose the type of terminal session you want to create. The Terminal Session Definition dialog box appears. This dialog box appears if you choose Telnet.

Field

Description

Value

Default

Mode

The type of terminal mode that you want to use for this terminal session.

VT100, VT220, VT320, ANSI, TN3270, TN5250

VT220

Note: If you edit a Telnet terminal session and you have set the mode to TN3270 or TN5250, you cannot change the mode. To change the mode, you must delete the terminal session and then create a new one with the new mode.

22

Page 457

DCS 300 System Manual Addendum

Communicating Through the Native Sockets Interface You can configure the DCS 300 to support Norand Native communications between terminals running in Native mode and a custom host application. These terminals present a simple read/write interface to the custom host application. The 1100, 1700, 5055, 5900, 6400, and 6550 terminals that run in the Intermec 2.4 GHz RF network or the Falcon 900 MHz network support Native mode. You may want to use Norand Native communications when you need to develop a custom host application and you cannot use standard terminal emulation. You can use Native syntax with the terminal Application Development Kit (ADK) to create client applications on the 6400 terminals. However, ADK applications are not supported on the 1100, 1700, 5055, 5900, and 6550 terminals. For more information on the ADK (Part No. 215-299-001), contact your local Intermec representative.

Setting Up the DCS 300 To set up the DCS 300 for Native communications, you must: •

Configure the DCS 300 for an Ethernet or token ring network. For help, see Chapter 3, “Connecting to an Ethernet/Token Ring Network” in the DCS 300 System Manual.

•

Configure the IP hosts and add the ports for the host applications. For help, see “Configuring IP Hosts” in this addendum.

•

Add a WTP network and define the Default Host Linking box, Native field. For help, see “Adding a WTP Network” in this addendum.

•

Configure any TE links. For help, see “Configuring TE Links” in this addendum.

Setting Up the Terminals For each terminal, you must use the menus to configure the radio network, Native communications, a terminal number, and the RF host stack number. Each terminal session must have a unique terminal number/RF host stack number combination. To set up the terminals 1. In the Main Menu select (1) Setup Parms. Enter the password. 2. Configure the LAN ID and the other radio parameters. These parameters must be set the same for all terminals and access points. 3. Use the host setup screens to configure the terminal session for Native communications, the unit (terminal) number, and the RF host (DCS 300) stack number. You configure Host A, Host B, and Host C independently. 4. Press Enter repeatedly to exit the menus.

23

Page 458

DCS 300 System Manual Addendum

Example This example walks you through the terminal screens to show you how to configure one of the terminal sessions for Host A, Native communications, terminal number 42, and the RF host stack number 0 (RF host name is MYHOST).

1) 2) 3)

Host A Host B Host C

1) Native 2) 3270 3) 5250 4) VT220

Enter Unit Number: 42

Native Unit # 42 Enter Host Name MYHOST 0

About the Host Application Requirements You may need to make some changes to your existing Norand Native host applications so they will work with the DCS 300. New feature You can now send the terminal session name, the RF host stack number, and the terminal number to the host. In the Port Configuration dialog box, check the Send ID check box. Unsupported command The DtE Terminal Echo-back Diagnostic command is not supported.

24

Page 459

DCS 300 System Manual Addendum

Converting to the DCS 300 From the 6950 EGS If your host application was written to work with the 6950 EGS, it should also work with the DCS 300 as long as the host application separates packets using a line feed (LF) character. If you did not write your host application for the 6950 EGS using delimiters, you must add an LF after each command. After you add the LFs, your host application will still work with the 6950 EGS.

Converting to the DCS 300 From WNAS or Serial Controllers If your host application was written to work with WNAS or Norand’s serially connected controllers, you must modify the application before it will work with the DCS 300. These next two sections explain the changes you need to make to the Native syntax and the considerations you need to understand when using sockets.

Changes to the Native Syntax If your host application was written to work with WNAS or Norand’s serially connected controllers, you must make some changes to the Native syntax before it will work with the DCS 300. You can obtain a complete description of Native syntax in Section 3 of the Terminal Commands of the Native Terminal Emulation Asynchronous Terminal Emulation Reference Guide (Part No. 977-047-038). Important: In the Native Terminal Emulation Asynchronous Terminal Emulation Reference Guide, you must use a line feed (LF) as the delimiter. You cannot use a carriage return (CR). For your host application to work with the DCS 300, you must make these syntax changes to the terminal commands: Write Display command (WtD...) You must remove the “Wt” portion of the command. Format the command as Doptions/data and write it to the socket. The socket number, not the terminal number, uniquely identifies each terminal to the application. The DCS 300 maintains the mapping between socket number and terminal number. Set Terminal Control Parameters command (StD…) You must replace the “St” portion of the command with a lowercase “e.” Format the command as eDoptions/parameters. Reset command (G) You must format the command by sending a lowercase “g” as a null-terminated string. Terminal Firmware Version command (DtV) You must format the command by sending a lowercase “v” as a null-terminated string.

25

Page 460

DCS 300 System Manual Addendum

Using Native Sockets If your host application was written to work with WNAS or Norand’s serially connected controllers, you must modify the application to use a socket interface instead of a serial port interface before it will work with the DCS 300. Terminals that are running in Native mode establish terminal sessions on the DCS 300 through a sockets interface. To use this interface, you must understand stream/sockets programming fundamentals. An excellent reference book for sockets programming is UNIX Network Programming by W. Richard Stevens (ISBN 0-13-949876-1). Note: Intermec does not provide application programming support for streams/sockets programming. The DCS 300 initiates communications with the host application through the configured port. Individual terminal sessions are mapped to unique sockets. Each terminal power up results in the DCS 300 opening another socket on the port to initiate the session with the host. The DCS 300 keeps an internal table mapping terminal numbers to socket numbers. These sockets (sessions) remain open until the host application closes the session using the Reset command, or a terminal cycles power resulting in the DCS 300 closing the old session and a new session being initiated.

Sample Program The nui_sock.c program is a sample C Language program that uses internet stream sockets to send Native syntax to a terminal via the DCS 300. This program uses a single user-assigned system port to communicate to multiple terminals, each connected via sockets under the control of the DCS 300. This program demonstrates the portability of Native applications from the WNAS or serial communications to the DCS 300. In order for the terminals to connect, you must configure the DCS 300 and terminals. For help, see “Setting Up the DCS 300” and “Setting Up the Terminals” earlier in this addendum. Note: On the DCS 300, when you configure the IP host and the port, do not check the Send ID check box in the Port Configuration dialog box. The nui_sock.c program does not expect the terminal ID. To run this program, you need to supply an available port number as an argument on the command line. For example, at a UNIX prompt you would type: ./nui_sock portnumber where portnumber is the port number that is configured for the IP host on the DCS 300. Once everything is configured correctly and terminals are powered up, a unique connection (socket) is established between each terminal and the nui_sock program. The terminal will begin with a prompt that says, “Enter data now:” This program lets you enter data and then it echoes the data you entered.

26