Page 361
B Helpful Information
Page 362
DCS 300 User’s Manual
Page 363
Helpful Information
B
This appendix provides helpful information for using the DCS 300 to verify your network connections, to transfer files, and to configure the TRAKKER Antares terminals.
Specifications Physical Specifications Length: 39.2 cm (15.25 in.) Height: 17.7 cm (6.97 in.) Width: 48.3 cm (19.0 in.) Weight: 12.35 kg (27.2 lb)
Electrical Specifications 100-120 VAC 200-240 VAC 47-63 Hz 250 Watts maximum North American or International power via autoswitching
Environment Specifications Operating: 10° to 50°C (50° to 122°F Storage: -20° to +60°C (-4° to +140°F) Humidity: 0 to 85% (non-condensing)
Other Specifications Network Independent Radio Independent Application Independent Central Network Management Automatic Restoration Software Distribution Accessories
Regulatory Approvals CE Marked, UL Listed, CSA, TÜV-GS, NOM, C-Tic
B-3
Page 364
DCS 300 User’s Manual
Converting Ethernet Addresses to Token Ring MAC Format When configuring the AS/400 host on the DCS 300, the LAN adapter address you specify depends on whether the controller and the host are on the same type of network. If the controller and AS/400 are on different types of networks, you must “byte-flip” the adapter card address.
Steps:
5 2
0 1 0 1
1 0 1 0
A
4
B-4
1
Convert to binary.
2
Reverse the order of the binary digits.
3
Convert to hexadecimal.
4
Swap places.
0 0 1 0
0 1 0 0
4
A
0300U.050
Page 365
Helpful Information
B
As a shortcut, you can use this table to byte-flip addresses. The table shows what each hexadecimal digit, from 0 to F, becomes when you perform Steps 1 to 3 (from the previous figure). Then you must perform Step 4. Byte Flipped Hexadecimal Equivalents 0 converts to
0
1 converts to
8
2 converts to
4
3 converts to
C
4 converts to
2
5 converts to
A
6 converts to
6
7 converts to
E
8 converts to
1
9 converts to
9
A converts to
5
B converts to
D
C converts to
3
D converts to
B
E converts to
7
F converts to
F
B-5
Page 366
DCS 300 User’s Manual
Using the DCS 300 to Verify Your Network Connections You can use the DCS 300 to verify it is correctly connected to the downline devices and to your host. You need to start data collection before you can use the server to send or receive transactions.
Sending Transactions Once you configure the DCS 300, you may want to verify that you have a connection between the server and a device or you may want to verify you have a connection between the server and the host application. Use the Send Transaction feature to send a transaction from a source to a destination. When sending a transaction to a device or an application (destination), make sure that your device or application is ready to accept the transaction. If it is not ready, the transaction is written to a Hot Standby file and you will need to clear the Hot Standby file before sending another transaction to the device or application. For help, see “Viewing and Clearing the Hot Standby Files” in Appendix A. To verify your connection 1. Make sure that you have saved and activated your run-time configuration. 2. Make sure that you have started data collection. 3. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 4. Select Send Transaction and then choose Start. The Send Transaction dialog box appears.
B-6
Page 367
Helpful Information
Field
Description
Value
Default
Source ID (Optional)
This field can contain the name that you want to use as the source of the transaction.
1 to 16 alphanumeric characters
None
Destination ID (Optional)
This field can contain the name of the device that you want to use as the destination of the transaction.
1 to 16 alphanumeric characters
None
Transaction ID (Optional)
This field can contain the transaction ID of the transaction that you want to send to all devices that accept it.
1 to 20 alphanumeric characters
None
Data or System
This field identifies the transaction to be a data or a system transaction.
D, S
D
Data (Optional)
This field contains any data that you want to send with the transaction ID.
1 to 1024 alphanumeric and special characters
None
B
B-7
Page 368
DCS 300 User’s Manual
Receiving Transactions Once you have configured the DCS 300, you may want to test your configuration by sending transactions from a device to an application without starting the application on the host. Or, you may want to send transactions to a device. The receive transactions feature can troubleshoot your connection to a destination. It lets the server emulate the destination, application, or device, without the destination being active. It also displays a list of transactions that the devices or applications sent to the destination. Note: Any transactions routed to the destination are intercepted by the server emulator and then they are displayed in the Receive Transactions dialog box. If you want the destination to receive the transaction, close the Application List dialog box and send the transaction again. To start the emulator to receive transactions 1. From the main menu sidebar buttons, choose Start Data Collection. The Start Data Collection message box appears. 2. Choose Start. 3. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 4. In the System Maintenance list box, select Receive Transactions and then choose Start. The Application List dialog box appears.
B-8
Page 369
Helpful Information
B
5. In the Application name field, enter the name of a destination. The destination name (application or device) must be defined in the server. 6. Choose Add. The Receive Transactions dialog box appears and the server begins emulating and monitoring incoming transactions for the destination.
7. Send a transaction from the application or device. The transaction appears in the Received Transactions box. 8. Choose Clear to delete all the received transactions in the Received Transactions box.
B-9
Page 370
DCS 300 User’s Manual
Using the DCS 300 to Transfer Files You can use the DCS 300 to send binary files, such as the reader program, to JANUS devices and TRAKKER Antares terminals. You can also send ASCII files, such as IRL files, templates, and validation files, to one or more devices in any network. Note: Currently, you cannot transfer files to WTP devices. Device
File Type
Transfer Method
JANUS 900 MHz RF device (v3.01 or later)
Binary
Binary file transfer (BFT)
JANUS 2.4 GHz RF device (v4.1 or later)
Binary
File transfer protocol (FTP)
TRAKKER Antares terminal
Binary
Terminal file transfer protocol (TFTP)
All devices
ASCII
ASCII
Note: To transfer files using BFT, your JANUS devices must have FTA.EXE and FTA.INI loaded on the C drive and they must be running a BFT-ready PSK application. You can copy FTA.EXE and FTA.INI from Application companion disk 3. To transfer files, you need to perform these tasks: 1. Make sure all the devices are ready to receive the files and data. If the device is not ready, the transaction is written to a Hot Standby file. 2. Make sure the server contains the files and data you want to download. You can put files onto the server using the Restore User Files feature. For help, see “Restoring Your User Files” in Chapter 2. 3. Use the download server to create logical groups so that you can send the files and data to more than one device. For help, see “Adding a Group in the Download Server” later in this appendix. 4. Start data collection. 5. Using the download server feature or download server commands, download the files and data to the terminal or group. For help, see “Using the Download Server to Transfer Files” or “Using the Download Server Commands to Transfer Files” later in this appendix.
B-10