A Troubleshooting
Page 342
DCS 300 User’s Manual
Page 343
Troubleshooting
A
This appendix describes the troubleshooting tools that are provided in the System Reporting and System Diagnostics sidebar buttons.
General Troubleshooting These problems are general system problems that may occur while you are using the DCS 300. Problem
Solution
The Intermec controller is not communicating with the DCS 300.
Make sure that you have defined the correct configuration for the controller on the DCS 300. Make sure you are using the correct Intermec cable. Replace the cable. Replace the serial card.
The green LED on the Ethernet card is not lit and the card is not communicating with the network.
Make sure that your Ethernet cable is securely plugged into the card and into an Ethernet connection. The default configuration for the Ethernet card is 10BaseT. If you are using 10Base2 or 10Base5, contact your local Intermec representative. Replace the cable. Replace the card.
The green LED on the token ring card is not lit and the card is not communicating with the network.
Make sure that your token ring cable is plugged into the card and into a token ring connection. If you are connected to a 4-Mbit ring, you need to reconfigure the card. Contact your local Intermec representative.
The green LED on the RF card is not lit and the card is not communicating with the network.
Verify that the devices are configured properly and are attempting to communicate with the network. Verify that you have configured the RF card and started data collection. Make sure that all cables are securely plugged into their connections. Contact your local Intermec representative.
A-3
Page 344
DCS 300 User’s Manual
General Troubleshooting (continued) Problem
Solution
The Intermec controllers are not communicating with the network.
Make sure the configuration for the controller in the DCS 300 GUI matches the configuration in the controller. Make sure that you are using the correct cables to connect your controller to your network. Contact your local Intermec representative.
Keystrokes are not displayed in a field.
Make sure your keyboard connector is securely seated in the keyboard port on the DCS 300. With the keyboard connected, shut down the DCS 300 and boot it. A keyboard echo failure has occurred. To release the keyboard, hold down the righthand Alt key and press the right-hand Ctrl key. Replace the keyboard.
The mouse does not work.
Make sure that your mouse connector is securely seated in the mouse port on the DCS 300. When the DCS 300 experiences electrical fast transients, the mouse may not work for a short period of time. Wait a few seconds and try using it again. Replace the mouse.
A-4
Page 345
Troubleshooting
A
Using the System Reporting Tools Use these tools and features, which are available under the System Reporting sidebar button, to help you troubleshoot error conditions: View runtime configuration Shows you the active (run-time) configuration. Use this feature to look at this configuration to determine what parameters you have defined. You can also save this file. View Hot Standby files Shows the contents of any Hot Standby files that reside on the server. You can also erase all messages in a Hot Standby file. View Status Monitor the error log file.
Shows the most recent error messages as they are being written to
View error log Provides information about message boxes and the error log. This section also gives you ideas about how to troubleshoot problems.
Viewing the Run-Time Configuration The DCS 300 produces a configuration file that you can view to verify the parameters that you have defined for the active configuration. To view the configuration 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box select View Runtime Configuration(s) and then choose Start. The View Runtime Configuration Options dialog box appears.
3. Check the configuration items that you want to view. 4. Choose Run View. The Runtime Configuration dialog box appears.
A-5
Page 346
DCS 300 User’s Manual
Runtime Configuration Dialog Box
5. Use the vertical scroll bar on the right side of the dialog box to view your run-time configuration. 6. If you want to save the file to the server, choose Save to Disk. 7. Choose Close to close the dialog box and return to the System Reporting dialog box.
A-6
Page 347
Troubleshooting
A
Viewing and Clearing the Hot Standby Files You can view the contents of the Hot Standby files that the DCS 300 creates when it places an application or device in Hot Standby mode. The server waits a certain period of time, which is set in the Hot Standby timeout, after delivering a transaction to an application or device to receive an acknowledgment for the transaction. If it does not receive an acknowledgment, the server writes all transactions for the application or device to a Hot Standby file. The application or device receives its transactions from the Hot Standby file when it either sends an acknowledgment to the most recently delivered transaction or when it sends a system transaction. Before the application or device becomes interactive, it receives all the transactions from oldest to newest that are in its Hot Standby file. You can use the Clear and Clear All buttons to erase all the messages in one Hot Standby file or to erase all the messages in all the Hot Standby files. You cannot erase single messages in a Hot Standby file. Clearing the Hot Standby files can interrupt data flow and you may lose transactions. For example, if you clear a Hot Standby file while transferring a file, the transfer stops, times out, and logs an error in the error file. Also, if you clear the Hot Standby file for an application while the application is connected to the controller, the application may need to send an Inter system transaction to resume communications. To view a Hot Standby file 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Hot Standby Files and then choose Start. The View Hot Standby Files dialog box appears.
3. Choose Update to make sure that you have the most current list. 4. Select the File Name that represents the Hot Standby file that you want to view and then choose View. The Hot Standby file appears.
A-7
Page 348
DCS 300 User’s Manual
To clear one or more Hot Standby files 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box, select View Hot Standby Files and then choose Start. The View Hot Standby Files dialog box appears. 3. Choose Update to make sure that you have the most current list. 4. Select the File Name that represents the Hot Standby file that contains all the messages that you want to delete and then choose Clear. Or, choose Clear All to delete all the error messages in all the Hot Standby files.
A-8
Page 349
Troubleshooting
A
Viewing the Status Monitor The DCS 300 Status Monitor provides a run-time view of the error messages. That is, it displays the most recent error messages as they are being written to the error log file. The clock in the lower right corner of the dialog box lets you verify the exact time when the error message occurred. To view the error log 1. From the main menu sidebar buttons, choose System Reporting. The System Reporting dialog box appears. 2. In the System Reporting list box select View Status Monitor and then choose Start. The DCS 300 Status Monitor dialog box appears.
3. In the Maximum # of messages displayed field, enter the number of error messages you want to list in the status monitor (10-9999). The default is 50 messages. When the number of error messages reaches this number, the oldest message is deleted. Note: Intermec recommends that you do not make this number too large since these error messages are stored in RAM. For help viewing the error log, see “Viewing Error Messages” in the next section. 4. Choose Clear if you want to clear all the messages in the status monitor. 5. Choose Close to close the dialog box and return to the System Reporting dialog box.
A-9
Page 350
DCS 300 User’s Manual
Viewing Error Messages There are two types of error messages that you may encounter when you are working on the DCS 300: • message box error messages
• error log error messages
If you cannot troubleshoot and fix an error message: 1. Write down the entire text of the message that is in the message box. 2. If the error message says to view the error log, open the error log. 3. Contact your network administrator to help you solve the problem. 4. Contact Intermec Technical Support to help you solve the problem.
Message Box Error Messages Message box error messages appear in message boxes on the DCS 300 screen. If your error message refers to the error log, then you must view the message in the error log. For help see “Error Log Error Messages” in the next section.
Error Log Error Messages The error log, NGERROR.LOG, provides a static view of all the error messages. If new error messages are generated while you are viewing the error log, you will not see them until you open the error log the next time. If you want to view error messages as the DCS 300 is logging them, open the status monitor. For help, see “Viewing the Status Monitor” earlier in this section. When messages are logged to the error log, no message box appears on the screen. The error log is limited to 700K and has two backup versions. When NGERROR.LOG reaches 700K, it is renamed to NGERLOG1.BAK. The next time the error log is full, NGERLOG1.BAK is renamed to NGERLOG2.BAK. Then, NGERROR.LOG becomes NGERLOG1.BAK. NGERLOG2.BAK is not backed up. Error log error messages are divided into the following parts: •
The first line contains the date and time the message was generated and information about the message, including the source that generated it. The format w-xxx-yyy represents: w is the subsystem number (the server is system 7), xxx is the module number of the source code, and yyy is the specific message number.
A-10
•
The second line contains the specific message.
•
There may be other lines that contain arguments pertaining to the error.