Page 91

Connecting to a Coaxial/Twinaxial Network

4

This chapter describes how to connect the DCS 300 to your host using a coaxial or twinaxial connection and it also explains how to configure the network adapter card.

Chapter Checklist Done?

‰ ‰

Task

Page

Install the server.

4-4

Use the GUI to configure the coaxial card for the coaxial network.

4-4

Or, Use the GUI to configure the twinaxial card for the twinaxial network.

4-5

If you already understand and have performed these tasks, connect the DCS 300 to another host or set up the host environment as described in these chapters: •

Chapter 3, “Connecting to an Ethernet/Token Ring Network”

•

Chapter 5, “Connecting to an SDLC Network”

•

Chapter 6, “Connecting to the Intermec RF Network”

•

Chapter 7, “Connecting to the 9180 and the Intermec CrossBar Network”

4-3

Page 92

DCS 300 User’s Manual

Installing the DCS 300 Before you can configure the DCS 300, you need to install it in your network.

Equipment •

A coaxial or twinaxial connection where you can connect the server.

•

A cable to connect the server to the connection. You can use a RG-58 coaxial cable, or for a twinaxial connection you can use 15 conductor IBM custom cable.

To install the server Coax

Twinax

1. Locate the slot that contains the coaxial or twinaxial card on the rear panel of your server. The twinaxial or coaxial card is the card that is furthest right when you are facing the front panel. Refer to the figure on the left. 2. Insert one end of the cable in the port and the other end in the coaxial or twinaxial connection.

0300U.023

0300U.022

Configuring the Coaxial Adapter Card If you have a coaxial network adapter card in the DCS 300, you do not need to enter any configuration parameters. You can choose the type of communication you are using, Local Network Adapter, and then Coaxial. This message box appears:

4-4

Page 93

Connecting to a Coaxial/Twinaxial Network

4

Configuring the Twinaxial Adapter Card After you install the DCS 300, you need to turn it on and configure its network adapter cards. Before you configure the network adapter card, obtain the server address and the maximum I-field size from your network administrator. To configure the network adapter card 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Local Network Adapter. Five buttons for different network adapter card types appear. 3. Choose Twinaxial. The Twinaxial Protocol Configuration dialog box appears.

Field

Description

Value

Default

Controller address

The address of the host twinaxial connection. This value must be unique for each twinaxial device connected to the host on this line.

0 to 6

0

Max I-field size

The maximum frame size that is used in this connection mode.

265 to 4105

1033

Saving Your Run-Time Configuration When you finish configuring your network adapter card, you should save your changes. To save your run-time configuration •

From the main menu sidebar buttons, choose Save Configuration.

4-5

Page 94

DCS 300 User’s Manual

6-6

Page 95

5 Connecting to an SDLC Network

Page 96

DCS 300 User’s Manual

Page 97

Connecting to an SDLC Network

5

This chapter describes how to install the DCS 300 in your SDLC network and configure the network adapter card.

Chapter Checklist Done?

‰ ‰

Task

Page

Install the server.

5-4

Use the GUI to configure the SDLC card for the SDLC network.

5-5

If you already understand and have performed these tasks, connect the DCS 300 to another host or set up the host environment as described in these chapters: •

Chapter 3, “Connecting to an Ethernet/Token Ring Network”

•

Chapter 4, “Connecting to a Coaxial/Twinaxial Network”

•

Chapter 6, “Connecting to the Intermec RF Network”

•

Chapter 7, “Connecting to the 9180 and the Intermec CrossBar Network”

5-3

Page 98

DCS 300 User’s Manual

Installing the DCS 300 Before you can configure the DCS 300, you need to install it in your network.

Equipment •

An SDLC connection where you connect the server.

•

An SDLC cable to connect the server to the connection. You can use a 25 conductor IBM custom cable.

Note: The SDLC card uses COM1. If you need more than one available serial port, you can purchase an Intermec serial I/O board. Note: The default configuration for the SDLC card is V.35. Contact your local Intermec representative if you need to use RS-232 communications. To install the server SDLC

1. Locate the slot that contains the SDLC card on the rear panel of your server. The SDLC card is the card that is furthest right when you are facing the front panel. The connector on the card looks like the figure on the left. 2. Insert one end of the cable in the port on the card and the other end in the connection.

0300U.024

5-4

Page 99

Connecting to an SDLC Network

5

Configuring the Network Adapter Card After you install the DCS 300, you need to turn it on and configure its network adapter cards. The SDLC card can use an internal or external clock at speeds up to 1 Mbps. Before you configure the network adapter card, obtain the local station address from your network administrator. You may also need to know the line type, line mode, NRZI, link station role, and maximum I-field size. To configure an SDLC network adapter card 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Local Network Adapter. Five buttons for different network adapter card types appear. 3. Choose SDLC. The SDLC Adapter Configuration dialog box appears.

4. In the Local station field, enter the address (in hex) that identifies the server station. The address can be from 01 to FE. The default is 01. 5. Configure any advanced SDLC parameters. For helps, see “Configuring Advanced SDLC Parameters” in the next section. 6. Choose OK to return to the SDLC Adapter Configuration dialog box. 7. Choose OK to return to the main menu.

5-5

Page 100

DCS 300 User’s Manual

Configuring Advanced SDLC Parameters •

From the SDLC Adapter Configuration dialog box, choose Advanced. The Advanced SDLC Adapter Protocol Configuration dialog box appears.

Field

Description

Value

Default

Line type

The type of telecommunications link that the server is using. Switched lines are the dialed type. Non-switched lines are the leased type.

Switched, Non-switched

Switched

Line mode

The type of cable you are using to connect the server to your host.

Full duplex, Half duplex

Half duplex

Internal clock

This check box determines if you are using an internal or external clock.

Check, Clear

Clear

Speed

The speed (in bps) of the internal clock.

4800, 9600, 19.2K, 38.4K, 56K, 64K, 128K, 192K, 256K, 384K, 560K, 840K, 960K, 1M

64K

NRZI (Non-Return-toZero Inverted)

The data encoding for modems that are sensitive to certain bit patterns.

On, Off

On

5-6