Page 105

9 Troubleshooting and Maintaining the Computer

If you encounter any problems while using the mobile computer, you can use the information in this chapter to find a possible solution. If you are not able to solve the problem, you can contact Intermec Product Support. You can also use the information in this chapter to learn how to reset and clean the mobile computer.

93

Page 106

Chapter 9, Troubleshooting and Maintaining the Computer

Troubleshooting Your Mobile Computer Use the troubleshooting tables in this section to fix problems with the Bluetooth connection, Wi-Fi connection, the phone, the imager, the camera, or general problems with operating the mobile computer. If you send the mobile computer in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the hardware matches the original configuration when repairing or replacing the computer.

Troubleshooting the Wi-Fi Connection Use this troubleshooting table to help solve problems with your 802.11 radio connection. Problems With the Wi-Fi Connection Problem

Solution

Host may have deactivated or lost current terminal When you turn on the computer after it was suspended for a while emulation session. In a TCP/IP direct connect network, turn (10 to 15 minutes or longer), it can off the “Keep Alive” message from host to maintain the TCP no longer send or receive messages session while the computer is suspended. over the network. The mobile computer is connected Move closer to an access point or to a different location to to the network and you move to a reestablish communications until you reconnect with the new site to collect data. Your mobile network. Any data collected while out of range is transmitted computer now shows you are not over the network. connected to the network. The mobile computer appears to be There may be a problem with the host computer, with the connected to the network, but you connection between the Intermec Application Server and the host computer, or with the connection between the access cannot establish a terminal point and the host computer. Check with the network emulation session with the host administrator to make sure the host is running and allowing computer. users to login to the system. The mobile computer appears to be There may be a problem with the connection between the connected to the network, but the access point and the host computer. Check with the network host computer is not receiving any administrator or use your access point user’s manual. information from the mobile computer.

94

CS40 Mobile Computer User’s Manual

Page 107

Chapter 9, Troubleshooting and Maintaining the Computer Problem

Solution

A network connection icon appears The mobile computer may not be communicating with the in the toolbar, but then disappears. intended access point. Make sure the mobile computer network name matches the access point network name. Default network name is “INTERMEC.” The access point may not be communicating with the server. Ensure the access point is turned on, properly configured, and has 802.1x security enabled.

Troubleshooting 802.1x Security Use the following table to troubleshoot problems with your 802.1x security that will prevent you from connecting to your network, such as a missing WEP key value or an incorrect password. Problems With 802.1x Security Problem

Solution

The computer indicates it is not authenticated.

Make sure that:

• the User Name and Password parameters on the computer must match the user name and password on authentication server. You may need to reenter the password on both the computer and authentication server. • on your authentication server, the user and group are allowed and the group policy is allowed to log into the server. For help, see the documentation that shipped with your authentication server software. • the IP address and secret key for access point must match the IP address and secret key on the authentication server. You may need to reenter the IP address and secret key on both your access point and authentication server. • the authentication server software is running on the server PC.

You receive a message saying “The Date and time are not saved when you perform a clean boot. server certificate has expired or your Reenter the date and time, and then save your changes. system date is incorrect” after you perform a clean boot on the computer.

CS40 Mobile Computer User’s Manual

95

Page 108

Chapter 9, Troubleshooting and Maintaining the Computer

Checking 802.11 Network Status If you have trouble connecting to your 802.11 wireless network: make sure you have correctly set network parameters on the mobile computer. • check your wireless security settings. Use iConnect to verify available access points and networks, check signal strength, and view other diagnostics. This information can also be helpful if you need to contact Intermec Product Support. •

To use iConnect to verify the network status: 1 Tap the iConnect icon ( computer screen.

) in the lower right corner of the mobile

2 Choose Status > Wireless. 3 Tap Advanced. The diagnostics screen appears. The ISpy tab shows the: •

MAC address and IP address of the 802.11 radio.

• network association status, including the SSID and MAC address of the access point.

• security configuration.

• radio transmit power and signal strength information. 4 Tap the Scan tab to view a list of available 802.11 networks. The list includes the signal strength, channel, and MAC address for each network. 5 Tap Scan to refresh the screen. 6 Tap the Supp tab to view radio supplicant information, including a list of supplicant events and authentication status.

96

•

To verify the settings for the currently active security profile, tap Configure Profile. The Profile Wizard for the active profile appears.

•

To try reconnecting to the network, tap Reconnect.

•

To delete the events in the list, tap Clear Events.

CS40 Mobile Computer User’s Manual

Page 109

Chapter 9, Troubleshooting and Maintaining the Computer

7 Tap the Ping tab to run a ping test to the host: a In the Host field, enter the IP address of the host. b From the Repetitions list, choose the number of times the mobile computer will ping the host. c

Tap Ping. The graph shows the amount of time it takes for the host to return the ping. Tap List to see this information in a list format.

8 Tap the RSSI tab to view the received signal strength of the host signal. The information box includes the current signal strength, host SSID name, MAC address, data rate, and transmit power. 9 Tap Mark to place an arrow marker above the graph. 10 Tap the Conf tab to set up a log file that lists RSSI history. This screen includes the 802.11 radio driver version and available radio modes. To create a log file: a Check the Log to File check box. b (Optional) Change the sample period and number of samples displayed. c

Tap Log File. The Save As screen appears.

d (Optional) Change the name of the saved log file, the folder to which the file will be saved, the content type (log or text), and the location. e Tap Save.

CS40 Mobile Computer User’s Manual

97

Page 110

Chapter 9, Troubleshooting and Maintaining the Computer

Troubleshooting Data Capture Use this section to troubleshoot problems that may prevent you from being able to read a bar code such as the symbology not be enabled. Problem

Solution

You cannot see a red beam of light • from the imager when you press the Scan button and aim the imager at a bar code label. •

You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. You may be reading the bar code label “straight on.” Change the reading angle and try again. • The imager hardware trigger might be disabled in Intermec Settings. To check the setting go to Start > Settings > Systems > Data Collection > Scanner Settings. Hardware trigger should be checked.

When you release the Scan The Good Read light stays on if you button, the Good Read LED does configure the computer to use not turn off. continuous/edge triggering. If you configure the computer for level triggering and the Good Read light remains on, there may be a problem. Press one of the Scan buttons or pull the trigger again without scanning a bar code label. If the light is still on, contact your local Intermec representative. The scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.

The scanner window may be dirty. Clean the window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

You scan a valid bar code label to The computer may have decoded the bar enter data for your application. code label in a symbology other than the label’s actual symbology. Try scanning The data decoded by the scan module does not match the data the bar code label again. Make sure you scan the entire label. encoded in the bar code label. The input device attached to the Set the Scanner Model command to the computer does not work well or specific attached input device. Check read bar code labels very quickly. enabled bar code symbologies and enable only the symbologies being used.

98

CS40 Mobile Computer User’s Manual

Page 111

Chapter 9, Troubleshooting and Maintaining the Computer Problem

Solution

The scanner will not read the bar • Aim the scanner beam to cross entire code label. bar code label in one pass. Vary the scanning angle. • Check the quality of the bar code label. Scan a bar code label that you know will scan. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology is enabled and configured correctly. Use Intermec Settings to check the symbologies. Expand Data Collection > Symbologies beneath devices listed (scanner, virtual wedge) to check and enable symbologies, then scan the bar code label again. • Make sure the computer application is expecting input from a bar code. You may need to type this information instead.

Troubleshooting Operating the Computer Use this section to troubleshoot problems that may prevent you from being able to operate the computer. Problem

Solution

You tap the screen and nothing happens.

Align your screen. For help, see “Aligning the Screen” on page 23.

The computer appears to be locked up and you cannot enter data.

• Press and hold the Power key for ten seconds to warm boot the computer.

• Try reloading the firmware. For help, see “Updating the System Software” on page 89. • If the computer does not boot or reset, contact your Intermec representative for help.

CS40 Mobile Computer User’s Manual

99

Page 112

Chapter 9, Troubleshooting and Maintaining the Computer Problem

Solution

You press the Power key and nothing happens.

The battery status LED indicates the following states:

• If the battery status LED is a steady green, the battery is more than 95% charged and computer is on a charger. • If the battery status LED is blinking red, the battery is low. Charge the battery. • If the battery status LED is a steady red, the main battery is on charge. • If the battery status LED is orange, the computer is trying to charge and either the battery temperature is outside of the charging range, or the battery is defective. You cannot type a character on the keypad or you can only type uppercase or lowercase letters.

You may have locked a modifier key on the keypad. Press the necessary key sequence to unlock the key. For help, see “About the Keypad” on page 11.

The phone feature is not working. Before you can use the phone, you need to activate it. For help, see “Activating the UMTS Phone” on page 30. You installed Intermec Terminal Emulator (ITE) or the Intermec Client Pack (ICP), and now the phone does not work.

By default, while ITE is running, the phone is disabled. You can enable the phone by modifying the Allow Phone Operations ITE setting in Intermec Settings.

Calling Product Support If you cannot find the answer to your problem in “Troubleshooting Your Mobile Computer” on page 94, you can visit the Intermec technical knowledge base (Knowledge Central) at intermec.custhelp.com to review technical information or to request technical support. If you still need help after visiting Knowledge Central, you may need to call Product Support. To talk to an Intermec Product Support representative, call: 1-800-755-5505

100

CS40 Mobile Computer User’s Manual

Page 113

Chapter 9, Troubleshooting and Maintaining the Computer

Before you can call Intermec Product Support, make sure you have the following information ready: Configuration number Serial number Operating system version SmartSystems Platform Bundle (SSPB) version If you are using security, know the type (Funk or Microsoft) and the full set of parameters • Power management settings • If you are using terminal emulation (TE), know the version and protocol. If you are not using TE, know the language your custom application was written in and the tools you used to create it. You can find most of the information listed above in Intermec Settings. Consult your application developer for information on your custom application. • • • • •

Finding Your Configuration Number Use the following procedure to help you find the configuration number of your mobile computer. •

Look at the label on the back of the computer.

Finding Your Operating System Version Use the following procedure to help you find your mobile computer’s OS version. 1 Tap Start > Internet Explorer. 2 Tap the Intermec logo. The Intermec page appears and displays the software build information.

CS40 Mobile Computer User’s Manual

101

Page 114

Chapter 9, Troubleshooting and Maintaining the Computer

Resetting the Computer You rarely need to reset the computer. If the computer does not resume after pressing the Power button, or if the computer or an application locks up, you may need to reset the computer. The computer uses the configuration currently saved in flash memory during the boot process. There are three ways to reset the computer: • • •

Warm booting the computer Cold booting the computer Clean booting the computer

Warm Booting the Computer You may need to perform a warm boot to correct conditions where an application stops responding to the system. There are two ways to do this: To warm boot the computer: 1 Tap Start > Programs > Shut Down. Or, scan this bar code.

The computer systematically shuts down. 2 Press the Power button to restart the computer. If the computer is connected to an external power supply, it automatically restarts.

Cold Booting the Computer In some cases where the computer completely stops responding, you may need to perform a cold boot. Cold booting may result in data loss, so use this method only if all other recovery methods have failed. Note: Cold booting the computer does not guarantee that cached disk data will be saved, so transactional data may be lost during the reset. All other data, such as computer configuration and network settings, is preserved.

102

CS40 Mobile Computer User’s Manual

Page 115

Chapter 9, Troubleshooting and Maintaining the Computer

To cold boot your computer: 1 If possible, tap Start > Programs > Shut Down. 2 Remove the battery pack from the computer and wait at least 30 seconds. 3 Install the battery pack and press the Power button.

Clean Booting the Computer A clean boot erases the memory in the mobile computer, including all applications and data files found in the ObjectStore, and loads only the default files and programs required by the computer operating system. During a clean boot, the computer first looks for the SSPB files on an installed microSD card. If no card is found, the computer loads the SSPB files in the Flash File Store. Files found on a microSD card during a clean boot are copied into the Flash File Store and overwrite the existing SSPB files. If the computer seems to be locked up, try warm booting and then cold booting the computer. If neither method works, use a clean boot to get the computer up and running for further troubleshooting. To clean boot the computer: 1 Remove the battery pack from the computer and wait at least 30 seconds. 2 Install the battery pack and press the Power button. 3 When the computer starts the boot process, simultaneously press and hold < and > until the IPL Boot Configuration Menu appears.

CS40 Mobile Computer User’s Manual

103

Page 116

Chapter 9, Troubleshooting and Maintaining the Computer

4 Press 2 to select Force Clean Boot, and then press 0 to select Continue with Boot. The computer clean boots. This process takes a few minutes. 5 When prompted, tap the screen to set up the computer. 6 Follow the instructions to align the screen.

Cleaning the Computer To keep the computer in good working order, you may need to clean the imager window, color camera window, and the touch screen. Clean the windows and the touch screen as often as needed for the environment in which you are using the computer. To clean the computer, use a solution of mild soap and warm water. There are no user-serviceable parts inside the computer. Opening the computer will void the warranty and may cause damage to the internal components. To clean the image window, camera window, and touch screen: 1 Tap Start > Shutdown to turn off the computer. 2 Dip a clean cloth towel in the soapy water and wring out the excess. 3 Wipe the imager window, camera lens, and flash area. Do not allow any abrasive material to touch these surfaces. 4 Wipe off any excess soap with a clean cloth towel dipped in warm water. 5 Wipe dry.

104

CS40 Mobile Computer User’s Manual