Page 173
4
Maintaining the CN30 Computer
Use this chapter to upgrade the operating system, solve problems you may encounter, and perform routine maintenance on your CN30 Mobile Computer. Note: Desktop icons and applet icons are shown to the left. Any place that Start is mentioned, tap the following Windows icon in the top, left corner of your CN30 desktop.
CN30 Mobile Computer User’s Manual
161
Page 174
Chapter 4, Maintaining the CN30 Computer
Upgrading the Operating System on your CN30 Computer You can use the Intermec Recovery Tools CD to reinstall or upgrade the operating system software on the CN30 Computer. For more information, contact your Intermec representative for more information about this CD. In future releases, a SmartSystems™ 2.0 client will be made available in the Shared Tech “bundle.” You can use the SmartSystems Foundation 2.0 application from Intermec to perform upgrades on your CN30 Computer, versions 2.0 or later. Contact your Intermec representative for more information about the SmartSystems Foundation software. When you upgrade the operating system, you erase the current configuration and replace it with the new default configuration. You will need to reset the network parameters on the CN30 Computer to reestablish communications with other devices in the network. In other words, if you upgrade the operating system and the default registry from the operating system has changed, the registry is rolled back to the new default.
Troubleshooting Your CN30 Computer If you have any problems using the CN30 Computer, look at the following for possible solutions: • Problems While Operating the CN30 Computer (page 163) • Problems While Configuring the CN30 Computer (page 163) • Problems While Configuring 802.1x Security (page 164) • Problems with Wireless Connectivity (page 165) • Problems Transmitting Data through the Serial Port (page 166) • Problems While Scanning Bar Codes (page 166) If you send the CN30 Computer in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your device.
162
CN30 Mobile Computer User’s Manual
Page 175
Chapter 4, Maintaining the CN30 Computer
Problems While Operating the CN30 Computer Problem
Solution
You press I to turn on the CN30 Computer and nothing happens.
• Make sure the backlight is on by pressing E. • Make sure you have a charged battery installed correctly. For help, see “Using the Battery” on page 8. • The battery may be discharged. Replace the battery with a spare charged battery, or charge the battery and try again. • Perform a warm-boot.
The Battery status LED is on.
• If the battery status LED is a steady green, the battery is more than 95% charged and unit is on a charger. • If the battery status LED is blinking red, then the battery is low. The speed of the blinking increases as the battery power gets increasingly lower. • If the battery status LED is a steady red, the main battery is on charge. • If the battery status LED is a steady amber for more than 12 hours, then replace the battery pack.
The CN30 Computer appears to be locked up and you cannot enter data.
• Press I to turn off the CN30 Computer, then press I again to turn on the CN30 Computer. • Press and hold I for ten seconds to warm-boot the CN30 Computer. • Perform a cold-boot on the CN30 Computer. See “Resetting Your CN30 Computer” on page16. • Try reloading the firmware. For help, see “Upgrading the Operating System on your CN30 Computer” on page 162. • If the CN30 Computer does not boot or reset, contact your local Intermec representative for help.
Problems While Configuring the CN30 Computer Problem
Solution
You scan a configuration command, such as Beeper Volume, and you hear three low beeps.
If you are working in the Intermec Settings applet, you cannot scan configuration commands. Exit the applet to scan configuration commands.
You scan or enter an option for the Scanner Model configuration command and you hear three low beeps.
You may have scanned or entered a Scanner Model command that does not apply to the type of scanner that you have installed. Try scanning or entering the Scanner Model command again and select an option for the type of device you are using.
You cannot type a character on the keypad or you can only type uppercase or lowercase letters.
You may have accidentally locked a modifier key on the keypad. Check the CN30 Computer status bar to see if it contains an icon with a locked symbol. Press the necessary key sequence to unlock the key. For help, see “Using the Keypad” on page 9.
CN30 Mobile Computer User’s Manual
163
Page 176
Chapter 4, Maintaining the CN30 Computer
Problems While Configuring 802.1x Security If you have trouble configuring the computer for 802.1x security, check these problems and possible solutions. Problems While Configuring 802.1x Security Problem
Solution
The CN30 Computer indicates that it is authenticated, but it does not communicate with the host.
Make sure that the CN30 IP address, host IP address, subnet mask, and default router are properly configured for your network. Note: Do not perform a cold-boot on the CN30 Computer. Doing so resets the time and date. You must also update the time and date for the Certificate of Authority.
The CN30 Computer does not appear to be authenticating and a network connection icon does not appear on the status bar.
The CN30 Computer may not be communicating with your access point. Make sure the network name on the CN30 Computer is the same as the network name (SSID) of the access point with which you are trying to communicate. The default network name is “INTERMEC.” The 802.1x security network may not be active. Make sure that the server software is properly loaded and configured on the server PC. For help, see the documentation that shipped with your server software.
A network connection icon appears in the status bar, but then disappears.
The CN30 Computer may not be communicating with the access point that you want it to communicate with. Make sure that the network name on the CN30 Computer is the same as the network name of the access point with which you are trying to communicate. The default network name is “INTERMEC.” The access point with which you are trying to communicate may not be communicating with the server. Make sure your access point is turned on, properly configured, and has 802.1x security enabled.
The CN30 Computer indicates that it is not authenticated.
Make sure that: • The Users Name and Password parameters on your CN30 Computer match the user name and password on your authentication server. You may need to reenter the password on both your CN30 Computer and the authentication server. • On your authentication server, the user and group are allowed and the group policy is allowed to log into the server. For help, see the documentation that shipped with your authentication server software. • The IP address and secret key for your access point must match the IP address and secret key on your authentication server. You may need to reenter the IP address and secret key on both your access point and authentication server. • The authentication server software is running on the server PC.
164
CN30 Mobile Computer User’s Manual
Page 177
Chapter 4, Maintaining the CN30 Computer
Problems While Configuring 802.1x Security (continued) Problem
Solution
You are setting up multiple access points in a network, with different SSIDs, and the connection fails.
The CN30 Computer does not save WEP key values when you change the SSID. Reenter the WEP key value after you change the SSID and select Apply Network Settings from the 802.11 Radio menu. You should now be able to connect to the different access points.
You receive a message saying “The server certificate has expired or your system date is incorrect” after you perform a cold-boot on the CN30 Computer.
The date and time on the CN30 Computer are not saved when a cold-boot is performed. You need to reenter the date and time and then select Apply Network Settings from the 802.11 Radio menu.
Problems with Wireless Connectivity Problem
Solution
When you turn on the CN30 Computer after it was suspended for a while (10-15 minutes or longer), it can no longer send or receive messages over the network.
The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “KeepAlive” message (if possible) from the host so that the TCP session is maintained while a CN30 Computer is suspended.
The No Network Connection icon appears on the status bar. The CN30 Computer is not communicating with the access point.
The CN30 Computer is not connected to the access point. Make sure the access point is turned on and operating. You may also be using the CN30 Computer out of range of an access point. Try moving closer to an access point to reestablish communications. Make sure the CN30 Computer is configured correctly for your network. The radio parameters on the CN30 Computer must match the values set for all access points with which the CN30 Computer may communicate. For help, see “Configuring 802.11b/g Radio Communications” on page 108. If you have an 802.11b radio, the radio initialization process may have failed. Try resetting the CN30 Computer. See “Resetting Your CN30 Computer” on page 16. If you have tried these possible solutions and the No Network Connection icon still appears, you may have a defective radio card. For help, contact your local Intermec representative.
The CN30 Computer is connected to the Intermec Application Server or host computer and you move to a new site to collect data. The Network Connection icon was visible, but is now replaced with the No Network Connection icon.
You may have gone out of range of an access point. Try moving closer to an access point or to a different location to reestablish communications. Once you are in range again, the Network Connection icon appears again. Any data you collected while out of range is transmitted over the network.
The Network Connection icon is in the status bar, but you cannot establish a terminal emulation session with the host computer.
There may be a problem with the host computer, a problem with the connection between the Intermec Application Server and the host computer, or a problem with the connection between the access point and the host computer. Check with your network administrator to make sure the host is running and allowing users to login to the system.
CN30 Mobile Computer User’s Manual
165
Page 178
Chapter 4, Maintaining the CN30 Computer
Problems with Wireless Connectivity (continued) Problem
Solution
The Network Connection icon is in the status bar, but the host computer is not receiving any data from the CN30 Computer.
In a UDP Plus network, there may be a problem with the connection between the Intermec Application Server and the host computer. Check with your network administrator or see the user’s manual for the Intermec Application Server. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual.
Problems Transmitting Data through the Serial Port If you are having problems sending or receiving data through the integrated serial port on the CN30 Computer, check these possible problems: • Make sure the CN30 Computer is connected to the PC, host computer, or RS-232 serial device using the appropriate cable adapter and null modem cable. • If the CN30 Computer is in a communications dock, make sure that the communications dock is connected to the serial device using the appropriate cable. For more information on using the serial port, see “Configuring Serial Communications” on page 107. Problems While Scanning Bar Codes Problem
Solution
You cannot see a red beam of light from the scanner when you press the Scan button and aim the scanner at a bar code label.
There are two possible problems: • You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Change the scanning angle and try again. You can test the effective range of the scanner. Move within 2 feet of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help scanning bar codes, see “Scanning Bar Codes” on page 5.
When you release the Scan button or handle trigger, the Good Read light does not turn off.
The Good Read light will remain on if you configure the CN30 Computer to use continuous/edge triggering. If you configure the CN30 Computer for level triggering and the Good Read light remains on, there may be a problem. Press the Scan button or pull the trigger again without scanning a bar code label. If the light is still on, contact your local Intermec representative.
The input device attached to the CN30 Computer does not appear to work well or read bar code labels very quickly.
Try setting the Scanner Model command to the specific input device you have attached. Check the bar code symbologies you have enabled on the CN30 Computer. Enable only the symbologies that you are using.
166
CN30 Mobile Computer User’s Manual
Page 179
Chapter 4, Maintaining the CN30 Computer
Problems While Scanning Bar Codes (continued) Problem
Solution
The scanner will not read the bar code label.
Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know will scan. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. Make sure the bar code symbology you are scanning is enabled. Use the Intermec Settings applet to check the symbologies. On the Data Collection option, expand the Symbologies option beneath each of the devices listed (scanner, virtual wedge) to see what symbologies has a check mark. If there is no check mark, then the bar code symbology is disabled. Check the symbology to enable it, then try scanning the bar code label again. Make sure that the application you are running on the CN30 Computer is expecting input from a bar code. You may need to type this information instead of scanning it.
The scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
The scanner window may be dirty. Clean the window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.
You scan a valid bar code label to enter data for your application. The data decoded by the scan module does not match the data encoded in the bar code label.
The CN30 Computer may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label. To operate the CN30 Computer quickly and efficiently, you should enable only the bar code symbologies that you are going to scan.
You receive a message reading “Scanner Communication Failure” when trying to connect a 1551E or 1553 decoded scanner.
Make sure that: you are using the correct cable, the scanner cable is attached correctly (when you attach the scanner to the port, it should emit a single power up beep), try enabling the port state using the Intermec Settings applet, try upgrading the scanner firmware, and you select ASCII as the scanner model.
Your 1551E or 1553 scanner was working fine, but after changing the port setting you cannot change the configuration.
The 1551E or 1553 scanner port must be using the correct RS-232 settings to allow configuration in the Intermec Settings applet. Try disabling, then enabling the scanner port state.
Configuration settings in the Intermec Settings applet do not match the settings on your 1551E or 1553 Scanner.
Try disabling, then enabling the scanner port state to synchronize the CN30 Computer settings with the scanner.
CN30 Mobile Computer User’s Manual
167
Page 180
Chapter 4, Maintaining the CN30 Computer
Cleaning the Scanner Window and CN30 Screen To keep the CN30 Computer in good working order, you may need to clean both the scanner window and the CN30 screen. Clean the scanner window and CN30 screen as often as needed for the environment in which you are using the CN30 Computer. To clean the CN30 Computer, use a solution of ammonia and water. There are no user-serviceable parts inside the CN30 Computer. Opening the unit will void the warranty and may cause damage to the internal components. Attention: Le CN30 ne contient pas de pièces réparables par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. Press (I) to turn off the CN30 Computer. Dip a clean towel or rag in the ammonia solution and wring out the excess. Wipe off the scanner window and screen. Do not allow any abrasive material to touch these surfaces. Wipe dry.
168
CN30 Mobile Computer User’s Manual