The text of a manual · part 13 of 17
CN3 Series Mobile Computer User's Manual for Windows Mobile 5.0: Chapter 4 - Troubleshooting and Maintaining the CN3
Pages 97 to 108 of 142, from CN3 Series Mobile Computer User's Manual for Windows Mobile 5.0
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec CN3
Page 97
4 Troubleshooting and Maintaining the CN3 If you encounter any problems while using the mobile computer, look in this chapter to find a possible solution. You will also find information on routine maintenance. This chapter contains these sections: •
Calling Product Support
•
Troubleshooting the CN3
•
Resetting the CN3
•
Cleaning the CN3
85
Page 98
Chapter 4, Troubleshooting and Maintaining the CN3
Calling Product Support If you cannot find the answer to your problem in the Troubleshooting the CN3 section, you can visit the Intermec technical knowledge base (Knowledge Central) at intermec.custhelp.com to review technical information or to request technical support. If you still need help after visiting Knowledge Central, you may need to call Product Support. To talk to an Intermec Product Support representative, call: 1-800-755-5505 Before you call Intermec Product Support, make sure you have the following information ready: •
Configuration number
•
Operating system version
•
SmartSystems Platform Bundle (SSPB) version
•
If you are using security, know the type (Funk or Microsoft) and the full set of parameters
•
Power management settings
•
If you are using terminal emulation (TE), know the version and protocol
•
If you are not using TE, know the language your custom application was written in and the tools you used to create it
You can find most of the information listed above in Intermec Settings. Consult your application developer for information on your custom application. To find your configuration number •
86
Look at the label on the back of the computer.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
Page 99
Chapter 4, Troubleshooting and Maintaining the CN3
To find your operating system or SSPB version 1 Tap Start > Internet Explorer.
2 Tap the Intermec logo. The Intermec page appears and displays the software build information.
Troubleshooting the CN3 If you send the CN3 in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the hardware matches the original configuration when repairing or replacing the computer. Problems While Configuring the CN3 Problem
Solution
You scan a configuration command, such as Beeper Volume, and you hear three low beeps.
If you are working in Intermec Settings, you cannot scan configuration commands. Exit the application to scan configuration commands.
You scan or enter an option for the Scanner Model configuration command and you hear three low beeps.
You may have scanned or entered a Scanner Model command that does not apply to the type of scanner that you have installed. Try scanning or entering the Scanner Model command again and select an option for the type of device you are using.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
87
Page 100
Chapter 4, Troubleshooting and Maintaining the CN3
Problems While Configuring the CN3 (continued) Problem
Solution
You cannot type a character on the You may have locked a modifier key on the keypad.Press keypad or you can only type uppercase the necessary key sequence to unlock the key. For help, or lowercase letters. see “Using the Keypad” on page 11.
Problems While Operating the CN3 Problem
Solution
You press the Power button and nothing happens.
• Make sure the backlight is on. • Make sure you have a charged battery that is installed correctly. For help, see “Charging the Battery” on page 5. • The battery may be discharged. Replace the battery with a spare charged battery, or charge the battery. • Perform a warm boot or a cold boot.
The Battery status LED is on.
The battery status LED indicates the following states: • If the battery status LED is a steady green, the battery is more than 95% charged and computer is on a charger. • If the battery status LED is blinking red, then the battery is low. Replace or charge the battery. • If the battery status LED is a steady red, the main battery is on charge. • If the battery status LED is amber, the CN3 is on charge and either the battery temperature is outside of the charging range, or the battery is defective.
The computer appears to be locked up • Press the power key to turn off the computer, then and you cannot enter data. press the power key again to turn it on. • Press and hold the power key ten seconds to warm boot the computer. • Try reloading the firmware. See “Upgrading the System Software” on page 78 . • If the computer does not boot or reset, contact your Intermec representative for help. You tap the screen and nothing happens.
88
Align your screen. For help, see “Aligning the Touch Screen” on page 21.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
Page 101
Chapter 4, Troubleshooting and Maintaining the CN3
Problems With Wireless Connectivity Problem
Solution
When you turn on the computer after it Host may have deactivated or lost current terminal emulation session. In a TCP/IP direct connect network, was suspended for a while (10 to 15 turn off the “Keep Alive” message from host to maintain minutes or longer), it can no longer the TCP session while the computer is suspended. send or receive messages over the network. The CN3 is connected to the network Move closer to an access point or to a different location to reestablish communications until you reconnect with and you move to a new site to collect data. Your CN3 now shows you are not the network. Any data collected while out of range is transmitted over the network. connected to the network. There may be a problem with the host computer, with The CN3 appears to be connected to the network, but you cannot establish a the connection between the Intermec Application Server and the host computer, or with the connection between terminal emulation session with the the access point and the host computer. Check with host computer. network administrator to make sure the host is running and allowing users to login to the system. In a TCP/IP network, there may be a problem with the The CN3 appears to be connected to the network, but the host computer is connection between the access point and the host not receiving any information from the computer. Check with network administrator or use your access point user’s manual. CN3.
Problems While Configuring 802.1x Security Problem
Solution
The CN3 indicates that it is authenticated, but it does not communicate with the host.
Make sure the CN3 IP address, host IP address, subnet mask, default router are configured for network.
The CN3 may not be communicating with the access The CN3 does not appear to be point. Make sure the CN3 network name matches the authenticating and a network connection icon does not appear on the access point network name (SSID). toolbar. 802.1x security network may not be active. Make sure the server software is properly loaded and configured on the server PC. See server software documentation for help.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
89
Page 102
Chapter 4, Troubleshooting and Maintaining the CN3
Problems While Configuring 802.1x Security (continued) Problem
Solution
A network connection icon appears in the toolbar, but then disappears.
The CN3 may not be communicating with the intended access point. Make sure the CN3 network name matches the access point network name. Default network name is “INTERMEC.” Access point may not be communicating with server. Ensure the access point is turned on, properly configured, and has 802.1x security enabled
You are setting up multiple access points in a network, with different SSIDs, and the connection fails.
CN3 does not save WEP key values when changing the SSID. Reenter the WEP key values and apply the network settings. You should now be able to connect.
You are setting up multiple access points in a network, with different SSIDs, and the connection fails.
The CN3 does not save WEP key values when changing the SSID. Reenter the WEP key value after changing the SSID and save your changes. You should now be able to connect to the different access points.
The CN3 indicates it is not authenticated.
Make sure that:
• the User Name and Password parameters on the CN3 must match the user name and password on authentication server. You may need to reenter the password on both the CN3, authentication server. • on your authentication server, the user and group are allowed and the group policy is allowed to log into the server. For help, see the documentation that shipped with your authentication server software. • the IP address and secret key for access point must match the IP address and secret key on the authentication server. You may need to reenter the IP address and secret key on both your access point and authentication server. • the authentication server software is running on the server PC.
You receive a message saying “The server certificate has expired or your system date is incorrect” after you perform a clean boot on the CN3.
90
Date and time are not saved when you perform a clean boot. Reenter the date and time, and then save your changes.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
Page 103
Chapter 4, Troubleshooting and Maintaining the CN3
Problems Scanning Bar Codes Problem
Solution
You cannot see a red beam of light from • the scanner when you press the Scan button and aim the scanner at a bar • code label.
You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. You may be scanning the bar code label “straight on.” Change the scanning angle and try again. • The scanner hardware trigger might be disabled in Intermec Settings. To check the setting go to Start > Settings > System Tab > Data Collection > Scanner Settings. Hardware trigger should be checked.
The input device attached to the computer does not work well or read bar code labels very quickly.
Set the Scanner Model command to the specific attached input device. Check enabled bar code symbologies and enable only the symbologies being used.
When you release a Scan button or handle trigger, the Good Read light does not turn off.
The Good Read light will remain on if you configure the computer to use continuous/edge triggering. If you configure the computer for level triggering and the Good Read light remains on, there may be a problem. Press one of the Scan buttons or pull the trigger again without scanning a bar code label. If the light is still on, contact your local Intermec representative.
The scanner will not read the bar code label.
• Aim the scanner beam to cross entire bar code label in one pass. Vary the scanning angle.
• Check the quality of the bar code label, Scan a bar code label that you know will scan. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology is enabled and configured correctly. Use Intermec Settings to check the symbologies. Expand Data Collection > Symbologies beneath devices listed (scanner, virtual wedge) to check and enable symbologies, then scan the bar code label again. • Make sure the computer application is expecting input from a bar code. You may need to type this information instead. The scanner does not read the bar code The scanner window may be dirty. Clean the window labels quickly, or the scanning beam with a solution of ammonia and water. Wipe dry. Do not seems to be faint or obscured. allow abrasive material to touch the window.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
91
Page 104
Chapter 4, Troubleshooting and Maintaining the CN3
Problems Scanning Bar Codes (continued) Problem
Solution
You scan a valid bar code label to enter The computer may have decoded the bar code label in a symbology other than the label’s actual symbology. Try data for your application. The data decoded by the scan module does not scanning the bar code label again. Make sure you scan match the data encoded in the bar code the entire label. label.
Resetting the CN3 You rarely need to reset the computer. If the computer does not resume after pressing the Power button, or if the computer or an application lock up, you may need to reset the CN3. The CN3 uses the configuration currently saved in flash memory during the boot process. There are three ways to reset the CN3: •
Warm booting the CN3
•
Cold booting the CN3
•
Clean booting the CN3
Warm Booting the CN3 You may need to perform a warm boot to correct conditions where an application stops responding to the system. To warm boot the computer •
Press and hold the Power button for 10 seconds or right-click on the CN3 via the SmartSystems Console and select Intermec Power Tools > Warm Boot Device.
The computer systematically shuts down, restarts, and goes through the initialization process.
92
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
Page 105
Chapter 4, Troubleshooting and Maintaining the CN3
Cold Booting the CN3 In some cases where the computer completely stops responding, it may be necessary to perform a cold boot. Because cold booting may result in data loss, only use this method if all other recovery methods have failed. Note: Cold booting the CN3 does not guarantee that cached disk data will be saved, so transactional data may be lost during the reset. All other data is preserved. To cold boot your CN3 1 Press the Power button to suspend the CN3. 2 Remove the battery pack from the CN3. 3 Press the Reset button on the back of the CN3.
Reset button
Locating the Reset Button on the CN3
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
93
Page 106
Chapter 4, Troubleshooting and Maintaining the CN3
Reset button
Locating the Reset Button on the CN3e
Clean Booting the CN3 When you clean boot the CN3, it loads only those files and programs that are absolutely required by the operating system. Use the clean boot to troubleshoot the CN3 by getting it up and running so that you can perform diagnostic tests to determine which elements of the normal boot process are causing problems. The clean boot process will erase the memory in the mobile computer, including all applications and data files found in the object store. A clean boot will load files from the Flash File Store if an SSPB files are not on a miniSD card. If SSPB files are on a miniSD card, they will overwrite the files in the Flash File Store. To clean boot the computer 1 Press the Power button to suspend the CN3. 2 Remove the battery pack from the back of the CN3. 3 With a stylus, press the Reset button on the battery cavity. 4 Insert the battery pack into the CN3 and immediately press and hold the Power button and both buttons on the left side. 94
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
Page 107
Chapter 4, Troubleshooting and Maintaining the CN3
5 Continue to hold the Power button and both buttons on the left side until a Warning message appears on the display. 6 Release the Power button and both buttons on the left side, read the message, and press either button on the right side to continue. 7 Wait for the CN3 to load files from the miniSD card. Note: You can also clean boot the CN3 using the SmartSystems console. To clean boot the CN3 using the SmartSystems Console, right-click on the CN3 and select Intermec Power Tools > Clean Boot Device.
Cleaning the CN3 To keep the CN3 in good working order, you may need to clean the imager window, color camera window, and the touch screen. Clean the windows and the touch screen as often as needed for the environment in which you are using the CN3. To clean the CN3, use a solution of ammonia and water. There are no user-serviceable parts inside the CN3. Opening the CN3 will void the warranty and may cause damage to the internal components. To clean the imager window, camera window, and touch screen 1 Press the Power button to suspend the CN3. 2 Dip a clean cloth towel in the ammonia solution and wring out the excess. 3 Wipe off the imager window, camera lens, and flash area. Do not allow any abrasive material to touch these surfaces. 4 Wipe dry.
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0
95
Page 108
Chapter 4, Troubleshooting and Maintaining the CN3
96
CN3 Series Mobile Computer User’s Manual for Windows Mobile 5.0