Page 164
B
Default Settings
CK31 Handheld Computer User’s Manual
147
Page 165
Appendix B, Default Settings
Default Configuration Use the following tables to see the default configuration settings of the CK31. If you restore the CK31 to factory default settings, it will use these values. The tables are organized according to the options in Intermec Settings. For detailed information on most of the commands available in Intermec Settings, see the Intermec Computer Command Reference Manual (P/N 073529). The Intermec Computer Command Reference Manual is available on the CD attached to the inside front cover of this user’s manual. You can check the Intermec web site for a more recent version of this online manual. Default Scanner Configuration
148
Symbology AustraliaPost
Default Value Disabled
Aztec
Disabled
BPO
Disabled
Codabar
Disabled
Codablock A
Disabled
Codablock F
Disabled
Code 11
Disabled
Code 2 of 5
Disabled
Code 39
Enabled
Code 93
Disabled
Code 128
Enabled
DataMatrix
Enabled
DutchPost
Disabled
EAN.UCC Composite
Disabled
Interleaved 2 of 5
Disabled
JapanPost
Disabled
Matrix 2 of 5
Disabled
Maxicode
Disabled
Micro PDF417
Disabled
CK31 Handheld Computer User’s Manual
Page 166
Appendix B, Default Settings
Default Scanner Configuration (continued) Symbology MSI
Default Value Disabled
PDF417
Enabled
Planet
Disabled
Plessey
Disabled
Postnet
Disabled
QR Code
Disabled
RSS 14
Disabled
RSS Limited
Disabled
RSS Expanded
Disabled
Telepen
Disabled
TLC 39
Disabled
UPC/EAN
Enabled
Symbology Options Preamble
Default Value No characters (disabled)
Postamble
No characters (disabled)
Global Symbology ID
Disabled
Scanner Settings Triggering Mode
Scanner Option Imager only
Default Value Level
Aim then Scan
Laser only
Disable
Hardware Trigger
Any scanner
Enable
Turn Off After Good Read
Any scanner
Enable/One-shot
Imager Settings Imager Decode Mode
Default Value 2D imager
Lighting Mode
Illum LED Priority
CK31 Handheld Computer User’s Manual
149
Page 167
Appendix B, Default Settings
Default Scanner Configuration (continued) Imager Settings Lighting Goal
Default Value 60
Image Dimension Top Position Bottom Position
0 479
Aimer LED Duration
0 ms
Sticky Aimer LED Duration
0 ms
Decode Security Settings Consecutive Data Validation
Default Value 0
Identical Consecutive Timeout
300 ms
Different Consecutive Timeout
0 ms
Virtual Wedge Settings Virtual Wedge Enable
Default Value Enable
Grid
Null
Default Communications Configuration
150
Communication Settings Device Name
Default Value WindowsCE
802.11 Radio Settings Security Choice
Default Value Funk Security
Funk Security Active Profile Profile Label Network Type Channel SSID Power Mode 8021x Association Encryption Pre-Shared Key
Profile 1 Profile_1 Infrastructure 3 INTERMEC Disabled (CAM) None Open None Null CK31 Handheld Computer User’s Manual
Page 168
Appendix B, Default Settings
Default Communications Configuration (continued) 802.11 Radio Settings
Default Value
IP Settings DHCP DHCP Client Identifier Primary DNS Secondary DNS Primary WINS Secondary WINS
Enabled Null 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
Bluetooth Settings Power
Default Value Off
Discoverable
Disable
Connectable
Disable
Class of Device
Null
IBT
0.16
Radio
525
Device Address
Text string
PSK Settings Protocol Selection
Default Value TCP/IP
Remote Connection Host IP Host Port Controller IP Controller Port
0.0.0.0 5555 0.0.0.0 5555
Serial Port Baud Rate Parity Data Bits Stop Bits Flow Control Protocol EOM1 EOM2 SOM Reader Command LRC Handshake
115200 bps Even 7 bits 1 stop bit None Configurable 0x03 No characters 0x02 Enabled without TMF Disable 0x00 - Disable
CK31 Handheld Computer User’s Manual
151
Page 169
Appendix B, Default Settings
Default Communications Configuration (continued) UDP Plus Settings UDP Plus Activate
Default Value Disable
Controller IP
0.0.0.0
Controller Port
5555
Ack Delay Upper Limit
5000 ms
Ack Delay Lower Limit
300 ms
Retries
7
Send Timer
20 s
Receive Timer
45 s
Default Device Settings Configuration Device Settings Date and Time Date Time Adjust for Daylight Time
Default Value
Beeper Volume
Very high
Number of Good Read Beeps
One
Beeper Duration Good Read Beep Low Beep High beep
80 ms 100 ms 150 ms
Beeper Frequency Good Read Beep Low Beep High beep
1950 Hz 512 Hz 1950 Hz
Tuesday, January 06, 2015 Time of current update Enabled
Display Backlight Timeout Maximum Backlight Level Backlight On Good Read Screen Rotation
152
15 seconds Low Off Disable
CK31 Handheld Computer User’s Manual
Page 170
Appendix B, Default Settings
Default Device Settings Configuration (continued) Device Settings Keypad Adjust Beeper Volume Task Manager Configure Boot Functionality
Default Value Enable Enable Warm boot
Power Management User Idle System Idle Suspend
1 minute 1 minute 1 minute
Backup Files Location
Flash File System
CK31 Handheld Computer User’s Manual
153
Page 171
Appendix B, Default Settings
154
CK31 Handheld Computer User’s Manual