The text of a manual · part 16 of 25
CK31 Handheld Computer User's Manual: Chapter 5 - Troubleshooting and Maintaining the CK31, pages 130 to 137
Pages 130 to 137 of 208, from CK31 Handheld Computer User's Manual
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec CK31
Page 130
5
Troubleshooting and Maintaining the CK31
Use this chapter to solve problems you may encounter while using the CK31. You will also find information on booting the computer and routine maintenance. If you have any problems using the CK31, look in this chapter to find a possible solution. This chapter consists of the following sections: Sections
Page
Calling Product Support
114
Problems While Operating the CK31
115
Problems While Configuring Security
117
Problems With Wireless Connectivity
119
Problems Transmitting Data Through the Serial Port
120
Problems While Scanning Bar Codes
121
Booting the CK31
125
Cleaning the Scanner Window and Screen
126
CK31 Handheld Computer User’s Manual
113
Page 131
Chapter 5, Troubleshooting and Maintaining the CK31
Troubleshooting the CK31 Use this chapter to troubleshoot some common problems you may experience with your CK31. If you cannot find the answer to your problem in the “Problems and Solutions” section, you may need to call Product Support.
Calling Product Support To talk to an Intermec Product Support representative, call 1-800-755-5505. Before you call Intermec Product Support, make sure you have the following information ready: • Operating system version • Configuration number • Power management settings • If you are using security, know the type (Funk or Microsoft) and the full set of parameters • If you are using terminal emulation (TE), know the version and protocol • If you are not using TE, know the language your custom application was written in and the tools you used to create it You can find most of the information listed above in Intermec Diagnostics or Intermec Settings. Consult your application developer for information on your custom application. To find your operating system version • Tap Start > Programs > Intermec Diagnostics > Software > OS Version. Note the OS version and then press Esc to exit. To find your configuration number • Tap Start > Programs > Intermec Diagnostics > Hardware > Configuration Table. Note the configuration number and then press Esc to exit. To open Intermec Settings • Tap Start > Intermec Settings. 114
CK31 Handheld Computer User’s Manual
Page 132
Chapter 5, Troubleshooting and Maintaining the CK31
Problems and Solutions You can also use the CK31 diagnostics to help analyze and solve problems. For help, see Chapter 4, “Running Diagnostics,” on page 95. If you send the CK31 in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your computer.
Problems While Operating the CK31 Problem You press I to turn on the CK31 and nothing happens.
Solution • Make sure the contrast is not set all the way to the darkest or lightest setting. Press B and then E repeatedly until you reach the desired contrast level. • Make sure the backlight is on by pressing E. • Make sure you have a charged battery installed correctly. • The battery may be discharged. Replace the battery with a spare charged battery, or charge the battery and try again. The Battery light is on.
The battery charge is low. You have a few minutes of power left. Immediately replace the battery with a spare charged battery, or charge the battery.
You use your stylus to tap the screen and nothing happens.
Recalibrate your touch screen. For help, see “Calibrating the Touch Screen” on page 19.
You cannot type a character on the keypad or you can only type uppercase or lowercase letters.
You may have accidentally locked a modifier key on the keypad. Check the CK31 taskbar to see if it contains an icon with a locked symbol. Press the necessary key sequence to unlock the key. For help, see “Using the Keypad” on page 7.
You insert an SD card and cannot find the SDMMC Disk folder on the CK31. Or, you insert a bootable SD card and the CK31 is not booting from the card.
The SD card may not be seated correctly. Push in on the SD card until you hear it unlatch and the card is ejected. Insert the SD card as described in Steps 3 and 4 of “Installing the SD Card” on page 34. If this does not solve the problem, try another SD card.
CK31 Handheld Computer User’s Manual
115
Page 133
Chapter 5, Troubleshooting and Maintaining the CK31
Problems While Operating the CK31 (continued) Problem The CK31 appears to be locked up and you cannot enter data.
Solution • Wait at least 10 seconds and try again. If the CK31 is still connecting to the Intermec Application Server or the host, it ignores any input from the keypad or scanner. • Press I to turn off the CK31 and then press I again to turn on the CK31. • Press and hold I for five seconds to warm boot the
CK31. • Perform a cold boot on the CK31. For help, see
“Cold Booting the CK31” on page 125. • Try reloading the firmware. For help, see
“Upgrading Your CK31” on page 92. • If the CK31 will not boot or reset, contact your local
Intermec service representative for help. The Backup Battery Very Low dialog box appears.
Click the X to close the dialog box. This dialog box continues to appear until the backup battery is fully charged. You must install a fully charged main battery or place the CK31 into a charger. The backup battery will fully charge in about 15 minutes. Do not swap the main battery until this dialog box stops appearing. If the Backup Battery Very Low dialog box continues to appear for more than 15 minutes, make sure that the backup battery is charging. Follow the instructions in “Battery Information” on page 98. If the Supercap Flag field on the battery information screen does not display Charging, you may need to send the CK31 to Intermec to replace the backup battery. For help, contact Product Support as described on page 114. You may also insert a fully charged main battery into the CK31 and allow the backup battery to charge overnight. In the morning, if the main battery is in good condition and can run the CK31, cold boot the CK31. The Backup Battery Very Low dialog box should not appear. If it does, contact Product Support.
116
CK31 Handheld Computer User’s Manual
Page 134
Chapter 5, Troubleshooting and Maintaining the CK31
Problems While Operating the CK31 (continued) Problem
Solution
The blue Ready-to-Work indicator is off.
Try these possible solutions: • The Ready-to-Work application (such as TE
2000) has not loaded successfully. For help, see the documentation or online help for the application. • The CK31 is not running a Ready-to-Work application. The blue Ready-to-Work indicator is blinking.
Try these possible solutions: • The Ready-to-Work application (such as TE
2000) may be running, but is not connected to a host. Verify that the application is properly configured to communicate with the host. • The CK31 may be connected to the network through an ActiveSync connection because it is not SmartSystems-enabled. Upgrade the CK31 to make it SmartSystems-enabled. The blue Ready-to-Work indicator is on.
A connection has been established, and all network connections are active. There is nothing to troubleshoot.
Problems While Configuring Security If you have trouble configuring the computer for security, check these problems and possible solutions. Problems While Configuring Security Problem You are using static WEP keys and you have a strong connection to the access point, but you cannot communicate with it.
Solution
You are setting up multiple access points in a network, with different SSIDs, and the connection fails.
The CK31 does not save WEP key values when you change the SSID. Re-enter the WEP key value after you change the SSID and save your changes. You should now be able to connect to the different access points.
Make sure that you are using the correct static WEP key. Sometimes you can see the strong signal strength and ) even though you have the security enabled icon ( WEP key set incorrectly.
CK31 Handheld Computer User’s Manual
117
Page 135
Chapter 5, Troubleshooting and Maintaining the CK31
Problems While Configuring Security (continued) Problem
Solution
You receive a message saying “The server certificate has expired or your system date is incorrect” after you cold boot the CK31.
The correct date and time on the CK31 are not always saved through a cold boot. You need to re-enter the date and time, and then save your changes.
The CK31 indicates that it is not authenticated.
Make sure that: • the User Name and Password on your CK31 match the user name and password on your authentication server. You may need to re-enter the password on both your CK31 and authentication server. • on your authentication server, the user and group are allowed and the group policy is allowed to log in to the server. For help, see the documentation that shipped with your authentication server software. • the IP address and secret key for your access point must match the IP address and secret key on your authentication server. You may need to re-enter the IP address and secret key on both your access point and authentication server. • your authentication server is active and can communicate with your access point. You can use the PING utility to determine communications by selecting Start > Programs > Intermec Diagnostics > System > Ping Utility. • the authentication server software is running on the server PC.
118
CK31 Handheld Computer User’s Manual
Page 136
Chapter 5, Troubleshooting and Maintaining the CK31
Problems With Wireless Connectivity Problem
Solution
When you turn on the CK31 after it was suspended for 10-15 minutes or longer, it can no longer send or receive messages over the network.
The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a CK31 is suspended.
The network connection icon is in the status bar, but the host computer is not receiving any data from the CK31.
In a UDP Plus network, there may be a problem with the connection between the Intermec Application Server and the host computer. Check with your network administrator or see the user’s manual for the Intermec Application Server. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual.
The no network connection icon ( ) appears on the status bar. The CK31 is not communicating with the access point.
• The CK31 is not connected to the access point.
Make sure the access point is turned on and operating. You may also be using the CK31 out of range of an access point. Try moving closer to an access point to re-establish communications. • Make sure the CK31 is configured correctly for your network. The radio parameters on the CK31 must match the values set for all access points the CK31 may communicate with. For help, see “Configuring 802.11b/g Radio Communications” on page 45. • If you have an 802.11b radio, the radio initialization process may have failed. Try resetting the CK31. See “Booting the CK31” on page 125. • If you have tried these possible solutions and the no network connection icon still appears, you may have a defective radio card. For help, contact your local Intermec service representative. The CK31 is connected to the Intermec Application Server or host computer and you move to a new site to collect data. The network connection icon was visible but now the no network connection icon ( ) is visible.
You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the network connection icon appears again. Any data you collected while out of range is transmitted over the network.
CK31 Handheld Computer User’s Manual
119
Page 137
Chapter 5, Troubleshooting and Maintaining the CK31
Problems With Wireless Connectivity (continued) Problem
Solution
While configuring or using wireless printing, you see the message, “The Bluetooth COM port does not exist [55]. This is probably because the computer was just resumed. Please wait a few seconds and try again.”
If you recently resumed the CK31, wait a few seconds and try again.
While configuring or using wireless printing, you see the message, “Bluetooth is off. Would you like to turn it on and continue?”
Tap Yes to dismiss the message. Follow the instructions in “Turning On Bluetooth Power” on page 51 to turn on the power to the Bluetooth radio.
Otherwise, you need to make sure that the device you selected as the current wireless printer is a printer, is turned on, and is discoverable. To learn about the current wireless printer and the Bluetooth COM port, see “Creating an Application That Lets You Print Wirelessly” on page 51.
Problems Transmitting Data Through the Serial Port If you are having problems sending or receiving data through the integrated serial port on the CK31, check these possible problems: • Make sure the CK31 is connected to the PC, host computer, or RS-232 serial device using the appropriate cable adapter and null modem cable. • If the CK31 is in a communications dock, make sure that the communications dock is connected to the serial device using the appropriate cable. • Make sure that ActiveSync is not connecting to the CK31 through the serial port. • You cannot use the decoded serial adapter or AA2 to connect to any device other than a decoded scanner. The CK31 autodetects the serial adapter or AA2, and the scanner software makes the COM port unavailable. Instead, use the AA3 to connect a device like a printer to the CK31. The AA3 requires an external power source. For more information on using the serial port, see “Configuring Serial Communications” on page 58. 120
CK31 Handheld Computer User’s Manual