Page 121

5

Running Diagnostics

The CK30 provides these diagnostics for troubleshooting. Diagnostic Test Battery Information Bluetooth Console

Page 109 111

Bootcode Version

112

Contrast Test

112

CPU Monitor Display Test Hardware Configuration Table Installed Fonts Intermec Value Add Information Keypad Test LED Test

CK30 Handheld Computer User’s Manual

113 114 114

Diagnostic Test Memory Information Network Connection Test Network Interface Information Operating System Version Ping Utility Radio Driver Version Radio Information

Page 117 117

119 120 120

115 115

RAM Monitor Read CPU Registers

121 121

116 116

Security Information Sound Test

122 123

118 119

107

Page 122

Chapter 5, Running Diagnostics

Using Diagnostics on the CK30 You can access the System Main Menu and select Diagnostics at any time while running an application. The Diagnostics menu contains these options: • Hardware Diagnostics • Software Diagnostics • System Diagnostics Use the Hardware Diagnostics menu to run tests on the CK30 or view system information. For example, you can run an LED test to determine if your CK30 lights are working correctly or you can view how much of a charge you have left in your main battery. Use the Software Diagnostics menu to view the version of your operating system, the bootcode version, and Intermec Value Add (IVA) information. Use the System Diagnostics menu to help analyze network, system, or applications problems on the CK30. For example, you can run diagnostics to check the network communications. To open the diagnostics menu 1 Press C and then B. 2 If you have set a password, enter it in the System Menu Access screen and press Enter. The System Main Menu appears. 3 Select Diagnostics.

4 Choose the diagnostics menu you want to use. 108

CK30 Handheld Computer User’s Manual

Page 123

Chapter 5, Running Diagnostics

To close the Diagnostics menu 1 Press Esc until you return to the System Main Menu. 2 From the System Main Menu, press Esc. 3 When the Exit Main Menu screen appears, press Enter. When you exit the System Main Menu, the CK30 resumes the application you were running when you opened the diagnostics menu.

Understanding the Diagnostics Screens This section lists all of the diagnostics screens in alphabetical order. You will see the following information for each diagnostics screen: • Description, purpose, and definition • Location of diagnostic in the System Main Menu • A sample diagnostics screen

Battery Information Use this diagnostic to view information on the main battery and backup battery. To open the Battery Information diagnostic • Go to Diagnostics > Hardware Diagnostics > Battery Info. Sample Screen

Charging in a Dock: The values in the Main Bat and Main Batt Flag fields indicate that this CK30 is charging in a dock.

CK30 Handheld Computer User’s Manual

109

Page 124

Chapter 5, Running Diagnostics

The Main Bat field displays the voltage of the AB1G battery as explained in the next table. Main Battery Status and Voltage Descriptions Status High

Voltage 8500 mV

Battery Charge Remaining 100%

High

> 8000 mV

> 75%

Medium

7600 to 7999 mV

50% to 75%

Low

7200 to 7599 mV

25% to 50%

Critically low

< 7199 mV

< 25%

The Main Batt Flag field displays the battery status, which is linked to the battery icon described on page 8. You can continue using the battery until the CK30 indicates that the battery is low: the battery light turns on and the low battery icon ( ) appears on the taskbar. The Supercap field displays the voltage of the backup battery as described in the next table. Backup Battery Status and Voltage Descriptions Status High

Voltage > 2400 mV

Condition Fully charged

High

> 2200 mV

OK to swap the main battery

Low

> 1750 mV

OK to swap the main battery if you first suspend the CK30

Low

< 1750 mV

Do not swap the main battery because the CK30 might cold boot

The main battery continually charges the backup battery unless the main battery is critically low or removed. There are some usage patterns that can cause the backup battery to become depleted. For example, if you remove the main battery every night to charge it outside the CK30, the backup battery will be low in the morning. This usage pattern does not harm the backup battery.

110

CK30 Handheld Computer User’s Manual

Page 125

Chapter 5, Running Diagnostics

When the backup battery is low, the Backup Battery Very Low dialog box appears on your CK30 screen.

Click the X to close the dialog box. The dialog box continues to appear until the backup battery is fully charged. You must install a fully charged main battery or place the CK30 in a charger. It takes about 15 minutes for the backup battery to charge up to 2.4V. If the Backup Battery Very Low dialog box continues to appear for more than 15 minutes, view the Battery Information diagnostic screen. If the Supercap Flag field is not Charging, the backup battery may have failed. You may need to send the CK30 to Intermec to have the backup battery replaced. For help, see “Calling Product Support” on page 126.

Bluetooth Console The Bluetooth Console is a tool that helps to debug the Bluetooth driver. You can use the Bluetooth Console to perform several Bluetooth diagnostics, such as deciding whether Bluetooth hardware was recognized and initialized correctly, setting a PIN, and establishing an L2CAP connection between two Bluetooth devices. For more information on using the Bluetooth Console (or BDTC), visit the Microsoft web site. To open the Bluetooth Console diagnostic • Go to Diagnostics > System Diagnostics > Bluetooth Console. CK30 Handheld Computer User’s Manual

111

Page 126

Chapter 5, Running Diagnostics

Sample Screen

Bootcode Version The Bootcode Version diagnostic displays the version of boot code loaded on your CK30. To open the Bootcode Version diagnostic • Go to Diagnostics > Software Diagnostics > Bootcode Version. Sample Screen

Contrast Test Use the Contrast Test to make sure the different contrast settings are working correctly on your CK30. The test will run through all of the settings and return you to your original setting. When you start the contrast test, the screen gradually gets darker until it is almost black and then it goes to the lightest setting which is almost white. The contrast test should take you through eight different levels of contrast. If your CK30 does not step through multiple levels of contrast, you may have a problem 112

CK30 Handheld Computer User’s Manual

Page 127

Chapter 5, Running Diagnostics with your display. For help, contact your local Intermec representative. To open the Contrast Test diagnostic • Go to Diagnostics > Hardware Diagnostics > Contrast Test. Sample Screen

CPU Monitor The CPU Monitor displays the activity of the CPU by using bars in a graphical icon. The bars in the icon represent the percentage of CPU cycles available as described in the next table. Number of Bars One

Percentage of CPU Cycles Available 80 to 100%

Two

60 to 80 %

Three

40 to 60%

Four

20 to 40%

Five

0 to 20%

If you see five bars, you may notice that the device seems slow and unresponsive. To open the CPU Monitor diagnostic • Go to Diagnostics > System Diagnostics > CPU Monitor. The CPU Monitor icon (

CK30 Handheld Computer User’s Manual

) appears on the taskbar.

113

Page 128

Chapter 5, Running Diagnostics

To close the CPU Monitor diagnostic 1 Go to Diagnostics > System Diagnostics > CPU Monitor. A dialog box appears asking if you want to stop the CPU Monitor. 2 Press Enter.

Display Test Use the Display Test to make sure that every pixel on the CK30 screen is working correctly. For example, you may want to test the screen if you do not see complete characters on the screen. The Display Test turns all pixels on, displays horizontal stripes, displays vertical stripes, and then turns all pixels off. If you have a color screen, the display test also changes your screen to blue, red, and then green. To open the Display Test diagnostic • Go to Diagnostics > Hardware Diagnostics > Display Test. Sample Screen

Hardware Configuration Table Use the HW Config Table to view important information about your CK30 such as the serial number, configuration number, model, software options, and the scanner type. You can use this information to tell the Intermec representative information on the hardware and software that were installed at the Intermec factory.

114

CK30 Handheld Computer User’s Manual

Page 129

Chapter 5, Running Diagnostics

To open the HW Config diagnostic • Go to Diagnostics > Hardware Diagnostics > HW Config Table. Sample Screen

Installed Fonts Use this screen to view all of the fonts installed on your CK30. To open the Installed Fonts diagnostic • Go to Diagnostics > Software Diagnostics > Installed Fonts. Sample Screen

Intermec Value Add Information Use this screen to see the versions of Intermec Value Add (IVA) products on your CK30. To open the IVA Info diagnostic • Go to Diagnostics > Software Diagnostics > IVA Info. CK30 Handheld Computer User’s Manual

115