Page 231

Command Quick Reference

D

Table D-2 SmartPass Commands Listed By Number Number

Command Name

Reader Message

823

Report changes on both

Done

90

Load program block

Done, Checksum Error, Program Error, or Verify Error

91

Verify flash checksum

Done or Error

96

Erase flash memory

Done

97

Perform destructive flash test

Done or Error

99

Exit download mode

Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.

Alphabetical Command List Note: The following conventions are used in Table D-3:

•

Items in bold italics identify factory default settings.

•

Only the data portion of the command number is shown.

•

Only the command-related data portion of the reader message is shown.

•

Refer to 7 for the complete syntax of commands and messages.

Table D-3 SmartPass Commands Listed by Command Name Command Name

Code

Reader Message

All IDs transmit

40

Done

Appended info status display

524

IDAP Tx Dx Xx T0 = time not appended T1 = time appended D0 = date not appended D1 = date appended X0 = aux info not appended X1 = aux info appended

Aux info append disable

310

Done or Error

Aux info append enable

311

Done or Error

Basic protocol select

610

Done or Error

D-13

Page 232

AI1620 SmartPass System Guide

Table D-3 SmartPass Commands Listed by Command Name

D-14

Command Name

Code

Reader Message

Baud rate = 110 baud set

1000

Done or Error

Baud rate = 1200 baud set

1002

Done or Error

Baud rate = 19.2 K baud set

1006

Done or Error

Baud rate = 2400 baud set

1003

Done or Error

Baud rate = 300 baud set

1001

Done or Error

Baud rate = 4800 baud set

1004

Done or Error

Baud rate = 9600 baud set

1005

Done or Error

Boot checksum display

543

BCKS xxxx xxxx = 4-byte ASCII checksum

Boot ROM checksum verify

667

Done or Error

Buffer all IDs

43

Done

Buffer control mode disable

6160

Done

Buffer control mode enable

6161

Done

Buffer control status display

535

BCM x 0 = disabled 1 = enabled

Buffer entry transmit

06

Done, Error, or Tag Data Done = buffer empty Error = not in buffer control mode Tag Data = highest priority tag ID

Check tag select internal

8160

Done

Check tag invoke

8110

Done

Comm port parameters display

522

MAIN Bx Sx Px D0 B0 = 110 B1 = 300 B2 = 1200 B3 = 2400 B4 = 4800 B5 = 9600 B6 = 19.2 S0 = one stop bit S1 = two stop bits P0 = no parity P1 = even P2 = odd D0 = EOL delay of 0 ms

Page 233

Command Quick Reference

D

Table D-3 SmartPass Commands Listed by Command Name Command Name

Code

Reader Message

Comm protocol display

525

ECPS Px Txx Xx S0 P0 = basic P1 = ECP P2 = data inquiry Txx = ECP timeout ms = 50 * xx TFF = disabled ECP timeout X0 = no flow control X1 = software flow control X2 = hardware flow control S0 = SOM character is #

Command mode switch

01

Done

Data inquiry protocol select

613

Done or Error

Data mode switch

00

Done

Date set S...S = MM/DD/YY

21S...S

Done or Error

Default operating parameters load

66F

Done or Error

Destructive flash test perform

97

Done or Error

Diagnostic results display

661

DIAG Rx Ex Dx Cx R0 = boot ROM OK R1 = boot failed E0 = flash memory OK E1 = flash failed D0 = external RAM OK D1 = RAM failed C0 = RTC OK C1 = RTC failed

Diagnostics perform all Use 661 to display diagnostic results.

669

Done or Error

Download mode exit

99

Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.

Download mode switch

05

Done

D-15

Page 234

AI1620 SmartPass System Guide

Table D-3 SmartPass Commands Listed by Command Name

D-16

Command Name

Code

Reader Message

Dual-frame processing mode display

536

DUAL x 0 = reset uniqueness on A, transmit A 1 = reset uniqueness on B, transmit B 2 = reset uniqueness on A, transmit both 3 = reset uniqueness on B, transmit both

Dual-frame processing mode select N=0 0 = Reset uniqueness on A, transmit A 1 = Reset uniqueness on B, transmit B 2 = Reset uniqueness on A, transmit both 3 = Reset uniqueness on B, transmit both

48N

Done

Echo disable

6170

Done

Echo enable

6171

Done or Error

Echo status display

537

ECHO x 0 = disabled 1 = enabled

ECP protocol select

611

Done or Error

ECP timeout = 12.7 sec set

612FE

Done or Error

ECP timeout set NN = 01–FE (1–255) timeout = 50 ms * NN (if NN = FF, timeout is disabled)

612NN

Done or Error

Even parity select

1021

Done

External RAM test

660

Done or Error

Flash checksum display

540

PCKS I0000 Exxxx xxxx = 4-byte ASCII checksum

Flash checksum verify

91

Done or Error

Flash memory checksum verify

668

Done or Error

Flash memory erase

96

Done

Flow control disable

6140

Done

Flow control enable

6141

Done

Page 235

Command Quick Reference

D

Table D-3 SmartPass Commands Listed by Command Name Command Name

Code

Reader Message

Hardware configuration information display

506

S...S S...S = ASCII string (maximum length of 20 characters)

Hardware configuration string store S...S = ASCII string (maximum length of 20 characters)

696S... S

Done

Hardware flow control enable

6142

Done

I/O status display

526

IOST Cx Ox Ix Dx C0 = host controls outputs C1 = predefined output mode O0 = both outputs off O1 = output0 on O2 = output1 on O3 = both outputs on I0 = both inputs false I1 = input0 true I2 = input1 true I3 = both inputs true D0–DF = output pulse duration (4,8,12,16,20,24,32,40,48,60, 76,152, 228,300,376,752 ms)

Input inversion disable

6940

Done

Input inversion enable

6941

Done

Input status change display

560

SSTC Ex Mx E0 = status change reports disabled E1 = status change reports enabled M0 = no reporting M1 = report change on input0 M2 = report change on input1 M3 = report change on either input

Input0 change report

821

Done

Input1 change report

822

Done

Odd parity select

1022

Done

Output pulse duration = 228 ms set

67C

Done or Error

D-17

Page 236

AI1620 SmartPass System Guide

Table D-3 SmartPass Commands Listed by Command Name

D-18

Command Name

Code

Reader Message

Output pulse duration set N = 0–F (4,8,12,16,20,24,32,40,48,60,76, 152, 228,300,376,752 ms)

67N

Done or Error

Output0 turn on

6201

Done

Output1 turn on

6202

Done

Outputs turn off both

6200

Done

Outputs turn on both

6203

Done

Parity disable

1020

Done

Periodic check tag disable

810

Done

Periodic check tag enable

8120

Done

Periodic check tag status display

550

SCTS Mx T5 M0 = periodic checktag disabled M1 = periodic checktag enabled T5 = periodic interval of 30 min

Power fail bit display

520

PWRB Px R0 P0 = no power fail has occurred P1 = power fail has occurred

Power fail bit reset

65

Done

Predefined output mode select

621

Done

Presence input status display

529

PRST Px D0 Ax Tx Ix P0 = disable presence without tag reports P1 = enable presence without tag reports D0 = minimum presence true period of 0 ms A0 = RF off on timeout A1 = RF off on timeout or tag A2 = RF off on timeout or no presence Tx = RF timeout period T0 = always expired T1–TE = (4,8,12,20,24,32, 48, 60,92,152,300,452,600,752 ms) TF = infinite I0 = input inversion disabled I1 = input inversion enabled

Presence without tag reports disable

6900

Done

Page 237

Command Quick Reference

D

Table D-3 SmartPass Commands Listed by Command Name Command Name

Code

Reader Message

Presence without tag reports enable

6901

Done

Program block load

90

Done, Checksum Error, Program Error, or Verify Error

Reader ID number display

521

RDID xx xx = 00–FF

Reader ID number set NN = 00

60NN

Done

Reader reset

63

Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.

Real-time clock test

664

Done or Error

Report changes both

823

Done

RF off

6400

Done

RF off on timeout

6920

Done

RF off on timeout/no presence

6922

Done

RF off on timeout/tag

6921

Done

RF on

6401

Done

RF on by input control

641

Done

RF operating frequency set

642

Done

RF operating range set

643NN

Done

RF status display

527

RFST Cx Ox T1 C0 = RF controlled by host C1 = RF-by-input control O0 = RF off O1 = RF on T1 = uniqueness timeout of 2 min

RF timeout = infinite set

693F

Done

RF timeout set N = 0–F (always expired, 4,8,12,20,24,32, 48,60,92,152,300,452,600,752 ms, infinite)

693N

Done or Error

D-19

Page 238

AI1620 SmartPass System Guide

Table D-3 SmartPass Commands Listed by Command Name

D-20

Command Name

Code

Reader Message

RF0 filter status display

530

RF0S Ux V0 U0 = one ID separation U1 = two ID U2 = transmit all U3 = buffer all

Selected checktag option display

551

CTAG x 0 = internal 1 = external

Serial number set S...S = ASCII string (maximum length of 6 characters)

695S... S

Done

Status change reports disable

820

Done

Stop bit use one

1010

Done

Stop bit use two

1011

Done

Tag ID separation select one

4100

Done

Tag ID separation select two

4101

Done

Tag translation mode disable

452

Done

Tag translation mode display

534

TT x 0 = disabled 1 = enabled

Tag translation mode enable

453

Done

Time and date append disable

300

Done or Error

Time and date append enable

302

Done or Error

Time and date display

22

HH:MM:SS.hh MM/DD/YY

Time set S...S = HH:MM:SS or HH:MM:SS:hh

20S...S

Done or Error

Version display

505

Model [model] Ver [ver no.] SN [serial no.]

Wiegand mode disable

450

Done

Wiegand mode enable

451

Done

Wiegand mode status display

532

T0F x 0 = disabled 1 = enabled

Page 239

Command Quick Reference

D

Table D-3 SmartPass Commands Listed by Command Name Command Name

Code

Reader Message

Wiegand retransmit interval display

533

WTI xx xx = 01–FF seconds

Wiegand retransmit interval set NN = 01–FF seconds

46NN

Done or Error

D-21

Page 240

AI1620 SmartPass System Guide

D-22