Page 231
Command Quick Reference
D
Table D-2 SmartPass Commands Listed By Number Number
Command Name
Reader Message
823
Report changes on both
Done
90
Load program block
Done, Checksum Error, Program Error, or Verify Error
91
Verify flash checksum
Done or Error
96
Erase flash memory
Done
97
Perform destructive flash test
Done or Error
99
Exit download mode
Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.
Alphabetical Command List Note: The following conventions are used in Table D-3:
•
Items in bold italics identify factory default settings.
•
Only the data portion of the command number is shown.
•
Only the command-related data portion of the reader message is shown.
•
Refer to 7 for the complete syntax of commands and messages.
Table D-3 SmartPass Commands Listed by Command Name Command Name
Code
Reader Message
All IDs transmit
40
Done
Appended info status display
524
IDAP Tx Dx Xx T0 = time not appended T1 = time appended D0 = date not appended D1 = date appended X0 = aux info not appended X1 = aux info appended
Aux info append disable
310
Done or Error
Aux info append enable
311
Done or Error
Basic protocol select
610
Done or Error
D-13
Page 232
AI1620 SmartPass System Guide
Table D-3 SmartPass Commands Listed by Command Name
D-14
Command Name
Code
Reader Message
Baud rate = 110 baud set
1000
Done or Error
Baud rate = 1200 baud set
1002
Done or Error
Baud rate = 19.2 K baud set
1006
Done or Error
Baud rate = 2400 baud set
1003
Done or Error
Baud rate = 300 baud set
1001
Done or Error
Baud rate = 4800 baud set
1004
Done or Error
Baud rate = 9600 baud set
1005
Done or Error
Boot checksum display
543
BCKS xxxx xxxx = 4-byte ASCII checksum
Boot ROM checksum verify
667
Done or Error
Buffer all IDs
43
Done
Buffer control mode disable
6160
Done
Buffer control mode enable
6161
Done
Buffer control status display
535
BCM x 0 = disabled 1 = enabled
Buffer entry transmit
06
Done, Error, or Tag Data Done = buffer empty Error = not in buffer control mode Tag Data = highest priority tag ID
Check tag select internal
8160
Done
Check tag invoke
8110
Done
Comm port parameters display
522
MAIN Bx Sx Px D0 B0 = 110 B1 = 300 B2 = 1200 B3 = 2400 B4 = 4800 B5 = 9600 B6 = 19.2 S0 = one stop bit S1 = two stop bits P0 = no parity P1 = even P2 = odd D0 = EOL delay of 0 ms
Page 233
Command Quick Reference
D
Table D-3 SmartPass Commands Listed by Command Name Command Name
Code
Reader Message
Comm protocol display
525
ECPS Px Txx Xx S0 P0 = basic P1 = ECP P2 = data inquiry Txx = ECP timeout ms = 50 * xx TFF = disabled ECP timeout X0 = no flow control X1 = software flow control X2 = hardware flow control S0 = SOM character is #
Command mode switch
01
Done
Data inquiry protocol select
613
Done or Error
Data mode switch
00
Done
Date set S...S = MM/DD/YY
21S...S
Done or Error
Default operating parameters load
66F
Done or Error
Destructive flash test perform
97
Done or Error
Diagnostic results display
661
DIAG Rx Ex Dx Cx R0 = boot ROM OK R1 = boot failed E0 = flash memory OK E1 = flash failed D0 = external RAM OK D1 = RAM failed C0 = RTC OK C1 = RTC failed
Diagnostics perform all Use 661 to display diagnostic results.
669
Done or Error
Download mode exit
99
Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.
Download mode switch
05
Done
D-15
Page 234
AI1620 SmartPass System Guide
Table D-3 SmartPass Commands Listed by Command Name
D-16
Command Name
Code
Reader Message
Dual-frame processing mode display
536
DUAL x 0 = reset uniqueness on A, transmit A 1 = reset uniqueness on B, transmit B 2 = reset uniqueness on A, transmit both 3 = reset uniqueness on B, transmit both
Dual-frame processing mode select N=0 0 = Reset uniqueness on A, transmit A 1 = Reset uniqueness on B, transmit B 2 = Reset uniqueness on A, transmit both 3 = Reset uniqueness on B, transmit both
48N
Done
Echo disable
6170
Done
Echo enable
6171
Done or Error
Echo status display
537
ECHO x 0 = disabled 1 = enabled
ECP protocol select
611
Done or Error
ECP timeout = 12.7 sec set
612FE
Done or Error
ECP timeout set NN = 01–FE (1–255) timeout = 50 ms * NN (if NN = FF, timeout is disabled)
612NN
Done or Error
Even parity select
1021
Done
External RAM test
660
Done or Error
Flash checksum display
540
PCKS I0000 Exxxx xxxx = 4-byte ASCII checksum
Flash checksum verify
91
Done or Error
Flash memory checksum verify
668
Done or Error
Flash memory erase
96
Done
Flow control disable
6140
Done
Flow control enable
6141
Done
Page 235
Command Quick Reference
D
Table D-3 SmartPass Commands Listed by Command Name Command Name
Code
Reader Message
Hardware configuration information display
506
S...S S...S = ASCII string (maximum length of 20 characters)
Hardware configuration string store S...S = ASCII string (maximum length of 20 characters)
696S... S
Done
Hardware flow control enable
6142
Done
I/O status display
526
IOST Cx Ox Ix Dx C0 = host controls outputs C1 = predefined output mode O0 = both outputs off O1 = output0 on O2 = output1 on O3 = both outputs on I0 = both inputs false I1 = input0 true I2 = input1 true I3 = both inputs true D0–DF = output pulse duration (4,8,12,16,20,24,32,40,48,60, 76,152, 228,300,376,752 ms)
Input inversion disable
6940
Done
Input inversion enable
6941
Done
Input status change display
560
SSTC Ex Mx E0 = status change reports disabled E1 = status change reports enabled M0 = no reporting M1 = report change on input0 M2 = report change on input1 M3 = report change on either input
Input0 change report
821
Done
Input1 change report
822
Done
Odd parity select
1022
Done
Output pulse duration = 228 ms set
67C
Done or Error
D-17
Page 236
AI1620 SmartPass System Guide
Table D-3 SmartPass Commands Listed by Command Name
D-18
Command Name
Code
Reader Message
Output pulse duration set N = 0–F (4,8,12,16,20,24,32,40,48,60,76, 152, 228,300,376,752 ms)
67N
Done or Error
Output0 turn on
6201
Done
Output1 turn on
6202
Done
Outputs turn off both
6200
Done
Outputs turn on both
6203
Done
Parity disable
1020
Done
Periodic check tag disable
810
Done
Periodic check tag enable
8120
Done
Periodic check tag status display
550
SCTS Mx T5 M0 = periodic checktag disabled M1 = periodic checktag enabled T5 = periodic interval of 30 min
Power fail bit display
520
PWRB Px R0 P0 = no power fail has occurred P1 = power fail has occurred
Power fail bit reset
65
Done
Predefined output mode select
621
Done
Presence input status display
529
PRST Px D0 Ax Tx Ix P0 = disable presence without tag reports P1 = enable presence without tag reports D0 = minimum presence true period of 0 ms A0 = RF off on timeout A1 = RF off on timeout or tag A2 = RF off on timeout or no presence Tx = RF timeout period T0 = always expired T1–TE = (4,8,12,20,24,32, 48, 60,92,152,300,452,600,752 ms) TF = infinite I0 = input inversion disabled I1 = input inversion enabled
Presence without tag reports disable
6900
Done
Page 237
Command Quick Reference
D
Table D-3 SmartPass Commands Listed by Command Name Command Name
Code
Reader Message
Presence without tag reports enable
6901
Done
Program block load
90
Done, Checksum Error, Program Error, or Verify Error
Reader ID number display
521
RDID xx xx = 00–FF
Reader ID number set NN = 00
60NN
Done
Reader reset
63
Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.
Real-time clock test
664
Done or Error
Report changes both
823
Done
RF off
6400
Done
RF off on timeout
6920
Done
RF off on timeout/no presence
6922
Done
RF off on timeout/tag
6921
Done
RF on
6401
Done
RF on by input control
641
Done
RF operating frequency set
642
Done
RF operating range set
643NN
Done
RF status display
527
RFST Cx Ox T1 C0 = RF controlled by host C1 = RF-by-input control O0 = RF off O1 = RF on T1 = uniqueness timeout of 2 min
RF timeout = infinite set
693F
Done
RF timeout set N = 0–F (always expired, 4,8,12,20,24,32, 48,60,92,152,300,452,600,752 ms, infinite)
693N
Done or Error
D-19
Page 238
AI1620 SmartPass System Guide
Table D-3 SmartPass Commands Listed by Command Name
D-20
Command Name
Code
Reader Message
RF0 filter status display
530
RF0S Ux V0 U0 = one ID separation U1 = two ID U2 = transmit all U3 = buffer all
Selected checktag option display
551
CTAG x 0 = internal 1 = external
Serial number set S...S = ASCII string (maximum length of 6 characters)
695S... S
Done
Status change reports disable
820
Done
Stop bit use one
1010
Done
Stop bit use two
1011
Done
Tag ID separation select one
4100
Done
Tag ID separation select two
4101
Done
Tag translation mode disable
452
Done
Tag translation mode display
534
TT x 0 = disabled 1 = enabled
Tag translation mode enable
453
Done
Time and date append disable
300
Done or Error
Time and date append enable
302
Done or Error
Time and date display
22
HH:MM:SS.hh MM/DD/YY
Time set S...S = HH:MM:SS or HH:MM:SS:hh
20S...S
Done or Error
Version display
505
Model [model] Ver [ver no.] SN [serial no.]
Wiegand mode disable
450
Done
Wiegand mode enable
451
Done
Wiegand mode status display
532
T0F x 0 = disabled 1 = enabled
Page 239
Command Quick Reference
D
Table D-3 SmartPass Commands Listed by Command Name Command Name
Code
Reader Message
Wiegand retransmit interval display
533
WTI xx xx = 01–FF seconds
Wiegand retransmit interval set NN = 01–FF seconds
46NN
Done or Error
D-21
Page 240
AI1620 SmartPass System Guide
D-22