Page 221
Command Quick Reference
D
The command numbers consist of from 2 to 4 hex digits. The letters N or S may follow a command number. The letter N indicates that part of the command number is variable. The letter S indicates the requirement for an alphanumeric data string that is to be included immediately following the command number. Hex digits (0–9, A–F) in either uppercase or lowercase characters may be used in data strings and for hex digits A–F. Table D-1 on page D-3 lists factory default settings. Table D-2 on page D-5 lists all of the commands available to users. Table D-3 on page D-13 lists the same commands by command name.
Factory Default Settings Table D-1 SmartPass Default Configuration Settings Parameter
Setting
Command
Operating mode
Data
00
Baud rate
9600
1005
Stop bits
1
1010
Parity
None
1020
End-of-line delay
0 ms
1030a
Time and date appended
Enabled
302
Auxiliary information appended
Disabled
310
Unique ID code criteria
Separation of 1 ID
4100
Valid ID code criteria
1 acquisition
4200a
Uniqueness timeout
2 minutes
441a
Wiegand mode
Disabled
450
Tag translation mode
Disabled
452
Wiegand transmit mode
1 second
4601
Dual processing mode
Reset on A, Transmit on A
4800
Reader ID number
00
6000
Communications protocol
Basic
610
D-3
Page 222
AI1620 SmartPass System Guide
Table D-1 SmartPass Default Configuration Settings (Continued) Parameter
Setting
Command
Error correcting protocol (ECP) timeout
12.7 sec
612FE
Flow control
Software (XON/XOFF)
6141
Start-of-message character
# (23 hex)
6150a
Buffer control mode
Disabled
6160
Echo mode
Enabled
6171 sense output control
Predefined
621
RF-by-input control
Enabled
641
RF operating frequency
902 MHz
64200
RF operating range
Maximum
6431F sense output pulse duration
228 ms
67C
Presence without tag reports
Disabled
6900
Minimum presence true period
0 ms
6910a
RF-off control
Timeout or no presence
6922
RF timeout
Never true
693F
Input inversion
Disabled
6940
Serial number
SSSSSS (6 digit number)
695
Store hardware configuration
Hardware configuration not known
696
Periodic system check tag
Disabled
810
Periodic check tag interval
30 min
8135a
Check tag location
Internal
8160a
Input status change reports
Disabled
820 a. Fixed parameter, not changeable by user.
D-4
Page 223
Command Quick Reference
D
Numerical Command List Note: The following conventions are used in Table D-2:
•
Items in bold italics identify factory default settings.
•
Only the data portion of the command number is shown.
•
Only the command-related data portion of the reader message is shown.
•
Refer to Chapter 6, “Communication Protocols,” for the complete syntax of commands and messages.
Table D-2 SmartPass Commands Listed By Number Number
Command Name
Reader Message
00
Switch to data mode
Done
01
Switch to command mode
Done
05
Switch to download mode
Done
06
Transmit buffer entry
Done, Error, or Tag Data Done = buffer empty Error = not in buffer control mode Tag Data = highest priority tag ID
1000
Set baud rate = 110 baud
Done or Error
1001
Set baud rate = 300 baud
Done or Error
1002
Set baud rate = 1200 baud
Done or Error
1003
Set baud rate = 2400 baud
Done or Error
1004
Set baud rate = 4800 baud
Done or Error
1005
Set baud rate = 9600 baud
Done or Error
1006
Set baud rate = 19.2 K baud
Done or Error
1010
Use one stop bit
Done
1011
Use two stop bits
Done
1020
Disable parity
Done
1021
Select even parity
Done
1022
Select odd parity
Done
D-5
Page 224
AI1620 SmartPass System Guide
Table D-2 SmartPass Commands Listed By Number
D-6
Number
Command Name
Reader Message
20S...S
Set time S...S = HH:MM:SS or HH:MM:SS:hh
Done or Error
21S...S
Set date S...S = MM/DD/YY
Done or Error
22
Display time and date
HH:MM:SS.hh MM/DD/YY
300
Disable time and date append
Done or Error
302
Enable time and date append
Done or Error
310
Disable aux info append
Done or Error
311
Enable aux info append
Done or Error
40
Transmit all IDs
Done
4100
Select one ID separation
Done
4101
Select two ID separation
Done
43
Buffer all IDs
Done
450
Disable Wiegand mode
Done
451
Enable Wiegand mode
Done
452
Disable tag translation mode
Done
453
Enable tag translation mode
Done
46NN
Set Wiegand retransmit interval NN = 01–FF seconds
Done or Error
Page 225
Command Quick Reference
D
Table D-2 SmartPass Commands Listed By Number Number
Command Name
Reader Message
48N
Select dual-frame processing mode N = 0–3 0 = Reset uniqueness on A, transmit A 1 = Reset uniqueness on B, transmit B 2 = Reset uniqueness on A, transmit both 3 = Reset uniqueness on B, transmit both
Done
505
Display version
Model [model] Ver [ver no.] SN [serial no.]
506
Display hardware configuration information
S...S S...S = ASCII string (maximum length of 20 characters)
520
Display power fail bit
PWRB Px R0 P0 = no power fail has occurred P1 = power fail has occurred
521
Display reader ID number
RDID xx xx = 00–FF
522
Display comm port parameters
MAIN Bx Sx Px D0 B0 = 110 B1 = 300 B2 = 1200 B3 = 2400 B4 = 4800 B5 = 9600 B6 = 19.2 S0 = one stop bit S1 = two stop bits P0 = no parity P1 = even P2 = odd D0 = EOL delay of 0 ms
524
Display appended info status
IDAP Tx Dx Xx T0 = time not appended T1 = time appended D0 = date not appended D1 = date appended X0 = aux info not appended X1 = aux info appended
D-7
Page 226
AI1620 SmartPass System Guide
Table D-2 SmartPass Commands Listed By Number
D-8
Number
Command Name
Reader Message
525
Display comm protocol
ECPS Px Txx Xx S0 P0 = basic P1 = ECP P2 = echo Inquiry Txx = ECP timeout ms = 50 * xx TFF = disabled ECP timeout X0 = no flow control X1 = software flow control X2 = hardware flow control S0 = SOM character is #
526
Display I/O status
IOST Cx Ox Ix Dx C0 = host controls outputs C1 = predefined output mode O0 = both outputs off O1 = output0 on O2 = output1 on O3 = both outputs on I0 = both inputs false I1 = input0 true I2 = input1 true I3 = both inputs true D0–DF = output pulse duration (4,8,12,16,20,24,32,40,48,60,76,1 52 228,300,376,752 ms)
527
Display RF status
RFST Cx Ox T1 C0 = RF controlled by host C1 = RF-by-input control O0 = RF off O1 = RF on T1 = uniqueness timeout of 2 min
529
Display presence input status
PRST Px D0 Ax Tx Ix P0 = disable presence w/o tag reports P1 = enable presence w/o tag reports D0 = min presence true period of 0 ms A0 = RF off on timeout A1 = RF off on timeout or tag A2 = RF off on timeout or no presence Tx = RF timeout period T0 = always expired T1–TE = (4,8,12,20,24,32,48,60,92, 152,300,452,600,752 ms) TF = infinite I0 = input inversion disabled I1 = input inversion enabled
Page 227
Command Quick Reference
D
Table D-2 SmartPass Commands Listed By Number Number
Command Name
Reader Message
530
Display RF0 filter status
RF0S Ux V0 U0 = one ID separation U1 = two ID U2 = transmit all U3 = buffer all
532
Display Wiegand mode status
T0F x 0 = disabled 1 = enabled
533
Display Wiegand retransmit interval
WTI xx xx = 01–FF seconds
534
Display tag translation mode
TT x 0 = disabled 1 = enabled
535
Display buffer control status
BCM x 0 = disabled 1 = enabled
536
Display dual-frame processing mode
DUAL x 0 = reset uniqueness on A, transmit A 1 = reset uniqueness on B, transmit B 2 = reset uniqueness on A, transmit both 3 = reset uniqueness on B, transmit both
537
Display echo status
ECHO x 0 = disabled 1 = enabled
540
Display flash checksum
PCKS I0000 Exxxx xxxx = 4-byte ASCII checksum
543
Display boot checksum
BCKS xxxx xxxx = 4-byte ASCII checksum
550
Display periodic check tag status
SCTS Mx T5 M0 = periodic checktag disabled M1 = periodic checktag enabled T5 = periodic interval of 30 min
551
Display selected check tag option
CTAG x 0 = internal 1 = external
D-9
Page 228
AI1620 SmartPass System Guide
Table D-2 SmartPass Commands Listed By Number
D-10
Number
Command Name
Reader Message
560
Display input status change
SSTC Ex Mx E0 = status change reports disabled E1 = status change reports enabled M0 = no reporting M1 = report change on input0 M2 = report change on input1 M3 = report change on either input
60NN
Set reader ID number NN = 00–FF
Done
610
Select basic protocol
Done or Error
611
Select ECP protocol
Done or Error
612NN
Set ECP timeout NN = 01–FE (1–255) timeout = 50 ms * NN (if NN = FF, timeout is disabled)
Done or Error
612FE
Set ECP timeout = 12.7 sec
Done or Error
613
Select data inquiry protocol
Done or Error
6140
Disable flow control
Done
6141
Enable software flow control
Done
6142
Enable hardware flow control
Done
6160
Disable buffer control mode
Done
6161
Enable buffer control mode
Done
6170
Disable echo
Done
6171
Enable echo
Done or Error
6200
Turn both outputs off
Done
6201
Turn output0 on
Done
6202
Turn output1 on
Done
6203
Turn both outputs on
Done
Page 229
Command Quick Reference
D
Table D-2 SmartPass Commands Listed By Number Number
Command Name
Reader Message
621
Select predefined output mode
Done
63
Reset reader
Model [model] Ver [ver no.] SN [serial no.] Copyright [date] AMTECH Corp.
6400
Turn RF off
Done
6401
Turn RF on
Done
641
Select RF-by-input control
Done
642
Set RF operating frequency
Done
643NN
Set RF operating range
Done
65
Reset power fail bit
Done
660
Test external RAM
Done or Error
661
Display diagnostic results
DIAG Rx Ex Dx Cx R0 = boot ROM OK R1 = boot failed E0 = flash memory OK E1 = flash failed D0 = external RAM OK D1 = RAM failed C0 = RTC OK C1 = RTC failed
664
Test real-time clock
Done or Error
667
Verify boot ROM checksum
Done or Error
668
Verify flash memory checksum
Done or Error
669
Perform all diagnostics Use 661 to display diagnostic results
Done or Error
66F
Load default operating parameters
Done or Error
67N
Set output pulse duration N = 0–F (4,8,12,16,20,24,32,40,48, 60,76,152,228,300,376, 752 ms)
Done or Error
D-11
Page 230
AI1620 SmartPass System Guide
Table D-2 SmartPass Commands Listed By Number
D-12
Number
Command Name
Reader Message
67C
Set output pulse duration = 228 ms
Done or Error
6900
Disable presence without tag reports
Done
6901
Enable presence without tag reports
Done
6920
Turn RF off on timeout
Done
6921
Turn RF off on timeout/tag
Done
6922
Turn RF off on timeout/no presence
Done
693N
Set RF timeout N = 0–F (always expired, 4,8,12,20,24, 32,48,60,92,152, 300,452, 600,752, infinite)
Done or Error
693F
Set RF timeout = infinite
Done
6940
Disable input inversion
Done
6941
Enable input inversion
Done
695S...S
Set serial number S...S = ASCII string (maximum length of 6 characters)
Done
696S...S
Store hardware configuration string S...S = ASCII string (maximum length of 20 characters)
Done
810
Disable periodic check tag
Done
8110
Invoke check tag
Done
8120
Enable periodic check tag
Done
8160
Select internal check tag
Done
820
Disable status change reports
Done
821
Report change on input0
Done
822
Report change on input1
Done