One-page Intermec quick start guide (P/N 962-000-044D, 2006) for the CK60/PB42 Quad Battery Charger, model AC4, which charges battery packs for the CK60 Handheld Computer and PB42 Portable Printer. It gives the battery and power supply part numbers, power usage, the charger features, how charging faults behave, and battery handling and disposal advice.

Device
Quad battery charger (Model AC4) for the CK60 Handheld Computer and PB42 Portable Printer p. 1
Capacity
Up to four battery packs in less than four hours at normal room temperature (21°C/70°F) p. 1
Battery
Intermec battery pack part number 805-630-002 only p. 1
Power supply
Intermec 12 VDC power supply, p/n 851-082-003, with an AC power cord for your location p. 1
Current draw
About 1 amp per charger power supply p. 1
Features
Four battery compartments, four charging status LEDs p. 1

What this manual walks you through

  • Understanding a fault condition while charging p. 1
  • Planning how many chargers share one circuit p. 1
  • Handling batteries safely p. 1
  • Disposing of spent batteries p. 1

Good to know

  • Only Intermec battery pack 805-630-002 may be charged; any other pack may present a fire or explosion hazard. p. 1
  • Only the appropriate Intermec power supply may be used, or equipment damage may occur. p. 1
  • A fault that does not clear in the normal operating temperature range may indicate a defective battery. p. 1
  • Batteries should not be stored above 60°C (140°F). p. 1
  • Batteries should not be recharged where it is extremely hot or cold, dusty or dirty, very humid, or subject to vibration. p. 1

Questions this manual answers

How long does the Intermec AC4 quad charger take to charge?

It charges up to four battery packs in less than four hours at normal room temperature (21°C/70°F). p. 1

Which battery does the CK60/PB42 Quad Battery Charger take?

Only Intermec battery pack part number 805-630-002. p. 1

What power supply does the Intermec AC4 charger use?

An Intermec 12 VDC power supply, p/n 851-082-003, which draws about 1 amp; 20 chargers can share one 20 amp circuit with no other loads on it. p. 1

Why does the quad charger show a fault?

Charging suspends with a fault when the battery temperature is outside the charger's normal operating range, and resumes once it returns to that range. p. 1

The file

Size and text

Pages1
PDF136 KB
TextText from the PDF itself.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Intermec AC4 Quad Charger Manual

The text of page 1, from the PDF itself

*962-000-044D*

www.intermec.com

No battery pack installed

Yellow

Radiated and Conducted Digital Emissions

Charge cycle in progress

Red

FCC Part 15 Class A Industry Canada ICES-003 Class A EN 55022: 1998/CISPR 22 Class A China CCC Emissions requirements

Charge cycle completeGreenFault conditionYellow

2006 Intermec Technologies Corporation. All rights reserved.

CK60/PB42 Quad Battery Charger

425.348.2600

Out of the Box The Intermec CK60/PB42 Quad Battery Charger (Model AC4) is an accessory for your CK60 Handheld Computer and PB42 Portable Printer. You can use your Quad Charger to charge up to four battery packs in less than four hours at normal room temperature (21°C/70°F). The CK60/PB42 Quad Battery Charger shipping box should contain these items:

tel

LED State

+5°C to +35°C (+41°F to +95°F) -30°C to 70°C (-22°F to +158°F) 5% to 95%

Quick Start Guide CK60/PB42 Quad Battery Charger CK60/PB42 Quad Battery Charger Start Guide Product Warranty Card Compliance Statement

an Intermec 12 VDC power supply p/n: 851-082-003 an AC power cord

You need to purchase the appropriate power cord for your location. For more information, contact your Intermec sales representative. You must use the appropriate Intermec power supply with this device or equipment damage may occur. The CK60/PB42 Quad Battery Charger is suitable for use only with Intermec battery pack part number 805-630-002. Use of any other battery pack may present risk of fire or explosion hazard.

Power Usage

CK60/PB42 Battery Charger Features

Each charger power supply (p/n: 851--082-003) uses approximately 1 amp of current. You can have 20 battery pack chargers plugged into one 20 amp circuit assuming no other loads are drawing off that circuit breaker.

Battery compartments (four) Charging Status LED (four)

Important Battery Handling Recommendations

What you need To use the CK60/PB42 Quad Battery Pack Charger, you need:

P/N 962-000-044D

CK60/PB42 Quad Battery Pack Charger Quick Start Guide

6001 36th Avenue West Everett, Washington 98203 U.S.A.

Worldwide Headquarters

If a fault condition does not clear under normal operating temperature range, this may indicate a defective battery. A fault condition displays and charging suspends if the battery temperature is outside the normal operating temperature for the charger. The fault clears and charging resumes when the battery temperature returns to the normal operating range. Condition

Operating Temperature:: Storage temperature: Relative Humidity:

Battery Pack Charging Status LEDs

Environmental

Specifications Charge the battery immediately before use or within a couple of days of use. Do not short circuit the battery and keep it away from metallic items. Do not disassemble, open, or modify the battery. Do not expose the battery to excessive heat or fire. Do not store the battery at temperatures above 60°C (140°F), such as inside a car on a hot day or in direct sunlight, as this may damage the battery. Do not immerse the battery in water or get the battery wet. Do not solder directly to the battery contacts. For maximum battery efficiency, the recommended temperature for charging and storing batteries is 21°C (70°F). Keep the battery contacts clean and free of dust and other contaminants. Do not recharge batteries in locations that are extremely hot or cold, dusty or dirty, very humid, or subject to vibration.

Battery pack in fully seated position

Battery pack

Power supply connector

Disposing of Batteries When the battery reaches the end of its useful life, the spent battery should be disposed of by a qualified recycle or hazardous materials handler. If you are unsure of how to properly dispose of this battery, contact your local Intermec sales representative for disposal information.