The text of a manual · part 24 of 25
MicroBar 9730 Decoder Installation Manual: E. Technical data
Pages 191 to 196 of 200, from MicroBar 9730 Decoder Installation Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9730
Page 191
E. Technical data
E. Technical data Input/output ports Overview - port 4 and port 5 are input ports - port 5 is Intermec input device compatible input data
P4
P5 P2 P3 input data / output data
P1 - ports 1, 2 and 3 are output ports - ports 1, and 2 can also be used as input ports when free (depending on output interface) - all ports are TTL level (port 4 also accepts RS-232 C level) - ports 1 and 2 accept cables used with the MicroBar NX and cable management modules (CMM) - all wedge connections can be made through port 3 with ScanPlus 1800 compatible cables - DEC VT 510, 520 can be connected as standard wedge - some Wyse terminals are PC-compatible and are considered as standard PC - laser and wand emulation outputs are not available as a standard options
MicroBar 9730 - Installation Manual
191
Page 192
E. Technical data Input/output ports
Input device priority management - input devices are classified in two priority groups : - high priority : RS-232 inputs on ports 4, 5 - low priority : wand, laser, magstripe inputs on ports 1, 3, 4, 5 - priority depends on the type of input device (RS-232, wand, laser, magstripe), not on the port simultaneous event priority levels high high priority management • 1st event processed first (top priority) • other event processed or lost depending on speed and protocol high low
• high-priority event processed correctly • low-priority event will be lost low low
• 1st event processed first (top priority) • second event will be lost
Output to host system port output interfaces cable comments
1&2 wedge (standard)
single passive cable set
Cxx compatible (601xxx-xx)
3 wedge Wyse / HP
Y smart
ScanPlus 1800 ST compatible
3 wedge DEC VT 220,320,420 / RS based
Y active
ScanPlus 1800 ST compatible
3 dual RS-232C
Y active
ScanPlus 1800 ST compatible
3
RS-232 C single active
ScanPlus 1800 ST compatible
3
RS-232 TTL single passive
ScanPlus 1800 ST compatible
3 cash registers (OCIA, IBM)
single smart
ScanPlus 1800 ST compatible
192
MicroBar 9730 - Installation Manual
Page 193
E. Technical data Input/output ports
I/O port functions To avoid power supply conflicts, do not connect more than one input power supply at a time (the 5V power supply pins on all ports are interconnected). port direction 1
2 devices comments to system for standard wedge (except Wyse & DEC 220/320/420)
passive cable - UBI 601xxx compatible input
5V power supply old UBI power supply cable end style (available if not already used for standard wedge transmission)
input external analog/digital pen
UBI wand compatible (available if not already used for standard wedge transmission)
to keyboard for standard wedge (except Wyse & DEC 220/320/420)
passive cable - UBI 601xxx compatible
5V power supply old UBI power supply cable end style (available if not already used for standard wedge transmission)
host system output cable
ScanPlus 1800 fully compatible cable type (without boot but adapted overmold)
output output connector 6-pin female modular plug, unscreened
6-pin female modular plug (no key), unscreened input
3 output
10-pin female modular plug, unscreened single passive type for RS-232 TTL single active type for RS-232 C single smart type for all cash registers & USB (when available) Y active type for dual RS-232 C Y smart type for special wedges (Wyse, DEC, ...)
input
4 input
9-pin subD female, unscreened
MicroBar 9730 - Installation Manual
1 analog/digital pen specific wand pin-out (available only if standard wedge transmission on ports 1 and 2)
undecoded laser gun
PSC/Symbol compatible
CCD scanner in wand emulation
193
Page 194
E. Technical data Input/output ports port direction
5 connector devices comments analog/digital pen
WA/DL compatible input
2 analog/digital pens using the UBI dual pen adaptor cable option input
RS-232 C input electronic scales or any other RS-232 C input device
Intermec wands
Intermec input device compatible including left hand key connectors input
10-pin modular female (LH key), unscreened undecoded laser gun CCD scanner in wand emulation analog/digital pen undecoded magnetic stripe reader dual tracks RS-232 TTL input
I/O port pinouts Port 1 pin pen wedge system
1
Data
Clock
2 power supply
Data
3 4 5
VDC
VDC
Power +5 VDC (I/O)
6
GND
GND
Power GND
Port 2 pin wedge keyboard
1
Clock
2
Data power supply
3 4
194
5
VDC
Power +5 VDC (I/O)
6
GND
Power GND
MicroBar 9730 - Installation Manual
Page 195
E. Technical data Input/output ports
Port 3 pin pen
RS-232 / dual RS-232 wedge RS (DEC, ...)
standard wedge smart cables
1
+5V output
+5V (I/O)
+5V (I/O)
+5V (I/O)
+5V (I/O)
keyboard active reset data
TXD (MicroBar 9730 output)
clock
RTS (MicroBar 9730 output)
2 3 4
TXD (MicroBar 9730 output)
5
RTS (MicroBar 9730 output)
6 data
TXD (MicroBar 9730 output)
RXD (MicroBar 9730 input)
RXD (MicroBar 9730 input)
7
CTS (MicroBar 9730 input)
8 cable detection (=+5V)
9 10
GND
RXD (MicroBar 9730 input) cable detection (=p8)
CTS (MicroBar 9730 input)
cable detection (=GND)
cable detection (=p9)
cable detection (=GND)
cable detection (=GND)
cable detection (=+5V)
cable detection (=p7)
cable detection (=GND)
GND
GND
GND
GND
Port 4 pin
RS-232 C laser pen port 4
2nd pen with port 4 adaptor
1
GND
SOS
Data do not connect
2
GND
Data do not connect
Data
3
TXD (output)
ACK/beep do not connect do not connect
4
CTS (input)
CTRL do not connect do not connect
5
GND trigger do not connect do not connect
6
RTS (output)
enable do not connect do not connect
7
GND
GND
GND
GND
8
RXD (input)
do not connect do not connect do not connect
9
VDC (I/O)
VDC (I/O)
VDC (I/O)
VDC (I/O)
MicroBar 9730 - Installation Manual
195
Page 196
E. Technical data Input/output ports
Port 5
196 pin laser pen
RS-232 TTL magstripe
1 do not connect do not connect
GND csl
2 decode do not connect
GND data iso2
3
SOS do not connect
TXD (output)
clk iso2
4 data data
RXD (input)
clk iso1
5 do not connect do not connect
GND tbd
6 beep do not connect
RTS (output)
data iso1
7 enable (active low)
do not connect do not connect do not connect
8 trigger do not connect
CTS (input)
do not connect
9
GND
GND
GND
GND
10
+5V (I/O)
+5V (I/O)
+5V (I/O)
+5V (I/O)
MicroBar 9730 - Installation Manual