Page 9

1. Using EasySet

1. Using EasySet - offline setup 1. select your Intermec product in EasySet ("Select reader" icon over the product image) 2. double-click the setup commands in EasySet to send them to the setup sheet 3. print out the setup sheet and read the configuration codes with a barcode reader - if you use a ScanPlus or MaxiScan 2200 barcode reader, print out and read the "ScanPlus / MaxiScan transparent configuration mode" code (see section 8, "Configuration modes and utilities") before you set up the MicroBar (if not, you will set up the ScanPlus / MaxiScan and not the MicroBar !) - online setup : - use RS-232 cable 0-234032-00 for online setup (follow the procedure described in this section)

start EasySet online setup

\41\4A\0F\29\60

- only necessary for setup with RS-232 cable 0-234032-00 - print out and read this code to activate online setup with EasySet (double-click the command to send it to the setup sheet) - follow the procedure for online setup with RS-232 cable 0-234032-00

MicroBar 9730 - Installation Manual

9

Page 10

1. Using EasySet online setup with RS-232 cable 0-234032-00 online setup with RS-232 cable 0-234032-00

RS-232 direct cable 0-234032-00

2

3 1

- online setup with RS-232 cable 0-234032-00 : 1. connect the RS-232 cable to port 3 of the MicroBar if it is not already connected 2. connect the RS-232 cable to the serial port of your PC 3. connect the power supply to the RS-232 cable and provide electrical power 4. select your Intermec product in EasySet ("Select reader" icon over the product image) 5. read the "start EasySet online setup" code (send it to the setup sheet and print it out, or read it from the Getting Started Guide or Installation Manual) 6. open the "Configure communication PC/Reader" dialog box in the "Reader" menu 7. select the COM serial port your product is connected to (19200 bauds, 8 data bits, no parity) 8. select the "Send to reader" checkbox under the commands window 9. double-click on the setup commands to send them directly to your product (they are also sent to the setup sheet) 10. connect your normal product cable to your product (if applicable) when you have finished online setup

10

MicroBar 9730 - Installation Manual

Page 11

2. Reset all parameters

2. Reset all parameters - global reset of all parameter settings - useful for a first-time setup or for a fresh start with a new application - default settings are indicated by (*) reset factory defaults

\46\42\60

- resets all configuration parameters to their default values and cancels the terminal / cash register selection - after a global reset, you must select the terminal / cash register used in your application (>> next section) and customize your setup parameters if required

MicroBar 9730 - Installation Manual

11

Page 12

2. Reset all parameters

12

MicroBar 9730 - Installation Manual