The text of a manual · part 7 of 11
97XX Wedge Interface Reference Manual, pages 61 to 70
Pages 61 to 70 of 109
The original document is the PDF (275 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9710
Page 61
IBM PC/XT/AT Series
Configuring the Reader Scan this label to configure the reader for your workstation. After the label is scanned, the reader emits one low beep followed by four low beeps. The four low beeps indicate the reader has successfully stored the configuration and is ready to read labels. If the reader emits a different beep sequence, refer to the Wedge Reader User's Manual, Section 2, for beeper identification. To Set Workstation Configuration to
Scan This Bar Code
Alfaskop DS/DT*
*$+TA171 *$+TA171
AST 286/386
*$+TA327* *$+TA327*
AT&T 605
*$+TA2* *$+TA2*
Compaq 286/386
*$+TA114* *$+TA114*
HP Vectra ES US Keyboard
*$+TA75* *$+TA75*
HP Vectra ES Belgian Keyboard
*$+TA86* *$+TA86*
HP Vectra ES Danish Keyboard
*$+TA83* *$+TA83*
HP Vectra ES French Keyboard
*$+TA78* *$+TA78*
HP Vectra ES French Canadian Keyboard
*$+TA85* *$+TA85*
HP Vectra ES German Keyboard
*$+TA76* *$+TA76*
51
Page 62
IBM PC/XT/AT Series
To Set Workstation Configuration to
Scan This Bar Code
HP Vectra ES 101/102-key Host-Connected Keyboard Map
*$+TA450*
HP Vectra ES Italian Keyboard
*$+TA84*
*$+TA450*
*$+TA84*
HP Vectra ES Norwegian Keyboard
*$+TA79* *$+TA79*
HP Vectra ES Spanish Keyboard
*$+TA77* *$+TA77*
HP Vectra ES Swedish/Finnish Keyboard
*$+TA81* *$+TA81*
HP Vectra ES Swiss French/German Keyboard Keyboard
*$+TA80*
HP Vectra ES United Kingdom Keyboard
*$+TA82*
*$+TA80*
*$+TA82*
IBM 7531, 7532
*$+TA312* *$+TA312*
IBM AT US 84/101/102-keyboard
*$+TA1* *$+TA1*
IBM AT French 102-keyboard
*$+TA29* *$+TA29*
IBM AT French 84-keyboard
*$+TA409* *$+TA409*
IBM AT German 102-keyboard
*$+TA31* *$+TA31*
52
Page 63
IBM PC/XT/AT Series
To Set Workstation Configuration to
Scan This Bar Code
IBM AT German 84-keyboard
*$+TA411* *$+TA411*
IBM AT 101/102-key Host-Connected US Keyboard Map
*$+TA450*
IBM AT Italian 102-keyboard
*$+TA32*
*$+TA450*
*$+TA32*
IBM AT Italian 84-keyboard
*$+TA410* *$+TA410*
IBM AT Spanish 102-keyboard
*$+TA30* *$+TA30*
IBM AT Spanish 84-keyboard
*$+TA412* *$+TA412*
IBM AT United Kingdom 102-keyboard
*$+TA28* *$+TA28*
IBM AT United Kingdom 84-keyboard
*$+TA413* *$+TA413*
IBM PC/XT US Keyboard
*$+TA0* *$+TA0*
IBM PC/XT French AZERTY Keyboard
*$+TA24* *$+TA24*
IBM PC/XT German Keyboard
*$+TA26* *$+TA26*
IBM PC/XT Italian Keyboard
*$+TA27* *#+TA27*
53
Page 64
IBM PC/XT/AT Series
To Set Workstation Configuration to
Scan This Bar Code
IBM PC/XT Spanish Keyboard
*$+TA25* *$+TA25*
IBM PC/XT United Kingdom Keyboard
*$+TA23* *$+TA23*
Idea Courier 9292
*$+TA305* *$+TA305
NEC 286/386
*$+T1* *$+TA1*
Nokia PC/XT Configured Keyboard
*$+TA216* *$+TA216*
NEC 286/386 101/102-keyboard Host-Connected US Map
*$+TA450*
Nokia AT Configured Keyboard
*$+TA171*
*$+TA450*
*$+TA171*
Nokia 7414-0011 Nokia VDU 192 AC42100.001 Keyboard
*$+TA239*
Nokia 7414-0011 Nokia VDU 192 AF51211 Keyboard
*$+TA240*
Tandy 1000 Enhanced Keyboard
*$+TA0*
*$+TA239*
*$+TA240*
*$+TA0*
Unisys PW2 286
*$+TA339* *$+TA1*
Wang 240, 280, 380 Model 724, 301 Keyboard
*$+TA1* *$+TA1*
54
Page 65
Idea Courier
Idea Courier This section covers these workstations: • •
Idea Courier 12471 Idea Courier 12472-01C
The individual Wedge Interface Guide for this section is part number 059308.
Cables Connecting the reader to one of these workstations requires two cables: a keyboard cable and a terminal cable. The interface kit contains both the keyboard and terminal cables. If you need to order a replacement cable, use the part numbers listed below: • • •
Wedge interface kit - Part No. 059309 Keyboard cable - Part No. 057470 Terminal cable - Part No. 057471
Power Supply If you use a 15XX laser scanner with these workstations, the reader requires an external power supply. Set the PCB jumper to connect pins 2 and 3 on the reader’s rear panel. If you use a wand with these workstations, the reader uses workstation power. Set the PCB jumper to connect pins 1 and 2.
Configuring the Reader Scan this label to configure the reader for your workstation. After the label is scanned, the reader emits one low beep followed by four low beeps. The four low beeps indicate the reader has successfully stored the configuration and is ready to read labels. If the reader emits a different beep sequence, refer to the Wedge Reader User's Manual, Section 2, for beeper identification. Note: This interface uses the standard Twinax/Coax keyboard mapping (Table A-2, in the Wedge Reader User’s Manual). Idea Courier US Keyboard (model 701920-001)
*$+TA202* *$+TA202*
55
Page 66
I-O Corporation Series
I-O Corporation Series This section covers these workstations: • • • • • •
I-O Corporation 1181D I-O Corporation 1181EP I-O Corporation 1181ES I-O Corporation 1181WP I-O Corporation 1196 I-O Corporation 1196D
• • • • •
I-O Corporation 1197 I-O Corporation 2196 I-O Corporation 2476C I-O Corporation 2497C I-O Corporation 2497D
The individual Wedge Interface Guide corresponding to this section is part number 055873.
Cables Connecting the reader to one of these workstations requires two cables: a keyboard cable and a terminal cable. The interface kit contains both the keyboard and terminal cables. If you need to order a replacement cable, use the part numbers listed below: • • •
Wedge interface kit - Part No. 055872 Keyboard cable - Part No. 055871 Terminal cable - Part No. 055870
Power Supply The reader does not require an external power supply to work with the workstation. Even though the reader does not require a power supply, set the PCB jumper to connect pins 2 and 3 on the reader’s rear panel. This is an exception for the I-O Corporation workstations.
Configuring the Reader Scan the appropriate label to configure the reader for your workstation. After the label is scanned, the reader emits one low beep followed by four low beeps. The four low beeps indicate the reader has successfully stored the configuration and is ready to read labels. If the reader emits a different beep sequence, refer to the Wedge Reader User's Manual, Section 2, for beeper identification. To Set Workstation Configuration to
Scan This Bar Code
I-O Corporation 83-key Keyboard
*$+TA321* *$+TA321*
56
Page 67
I-O Corporation Series
To Set Workstation Configuration to
Scan This Bar Code
I-O Corporation 102-key Keyboard
*$+TA322* *$+TA322*
I-O Corporation 122-key Keyboard
*$+TA323* *$+TA323*
57
Page 68
LynkLyte Series
LynkLyte Series This section covers the LynkLyte 1 workstation. The individual Wedge Interface Guide corresponding to this section is part number 055756.
Cables Connecting the reader to the LynkLyte workstation requires two cables: a keyboard cable and a terminal cable. The interface kit contains both the keyboard and terminal cables. If you need to order a replacement cable, use the part numbers listed below: • • •
Wedge interface kit - Part No. 054849 Keyboard cable - Part No. 054848 Terminal cable - Part No. 054847
Power Supply The reader does not require an external power supply to work with the workstation. Set the PCB jumper to connect pins 1 and 2 on the reader’s rear panel.
Configuring the Reader Scan the appropriate label to configure the reader for your workstation. After the label is scanned, the reader emits one low beep followed by four low beeps. The four low beeps indicate the reader has successfully stored the configuration and is ready to read labels. If the reader emits a different beep sequence, refer to the Wedge Reader User's Manual, Section 2, for beeper identification. To Set Workstation Configuration to
Scan This Bar Code
LynkLyte 1 (5 pin PC/XT DIN) 102-key Keyboard
*$+TA307* *$+TA307*
LynkLyte 1 (7-pin DIN) 122-key Keyboard
*$+TA306* *$+TA306*
58
Page 69
Macintosh II and SE Series
Macintosh II and SE Series This section covers these workstations: • •
Macintosh SE Macintosh II
The individual Wedge Interface Guide corresponding to this section is part number 054842.
Cables Connecting the reader to one of these workstations requires a terminal cable. The expansion cable is required when connecting other input devices (for example, a mouse). The interface kit contains both the expansion and terminal cables. If you need to order a replacement cable, use the part numbers listed below: • • •
Wedge interface kit - Part No. 054841 Expansion cable - Part No. 054840 Terminal cable - Part No. 054839
Power Supply The reader does not require an external power supply to work with the workstations. Set the PCB jumper to connect pins 1 and 2 on the reader’s rear panel.
Configuring the Reader Scan the appropriate label configure the reader for your workstation. After the label is scanned, the reader emits one low beep followed by four low beeps. The four low beeps indicate the reader has successfully stored the configuration and is ready to read labels. If the reader emits a different beep sequence, refer to the Wedge Reader User's Manual, Section 2, for beeper identification. To Set Workstation Configuration to
Scan This Bar Code
US and United Kingdom Keyboard
*$+TA175* *$+TA175*
Danish Keyboard
*$+TA178* *$+TA178*
59
Page 70
Macintosh II and SE Series
To Set Workstation Configuration to
Scan This Bar Code
Dutch Keyboard
*$+TA134* *$+TA134*
Finnish Keyboard
*$+TA135* *$+TA135*
Flemish and French Keyboard
*$+TA185* *$+TA185*
French Canadian Keyboard
*$+TA177* *$+TA177*
German Keyboard
*$+TA300* *$+TA300*
Italian Keyboard
*$+TA274* *$+TA274*
Icelandic Keyboard
*$+TA275* *$+TA275*
Norwegian Keyboard
*$+TA276* *$+TA276*
Portuguese Keyboard
*$+TA277* *$+TA277*
Spanish Keyboard
*$+TA278* *$+TA278*
Swedish Keyboard
*$+TA279* *$+TA279*
Swiss (French and German) Keyboard
*$+TA299* *$+TA299*
60