For the Intermec 9560

Page 71

Operating the 9560

4

4. Practice using the wand on the following label. Be sure to hold the wand at a slight angle. Lightly touch the label when scanning.

*LABEL* *LABEL*

Using a Laser Scanner You can use Intermec 1500 and 1600 series laser scanners with the 9560. Refer to the documentation supplied with the laser scanner for specific operating instructions, warnings, and cautions.

WARNING

Warning Do not look directly into the window area while the laser is scanning. Long term exposure to the laser beam can damage vision. Avertissement Ne regardez pas directement la région de la fenêtre pendant le passage du laser. L'exposition à long terme au rayon laser peut endommager la vue.

To scan a label 1. Hold the scanner in the palm of your hand with the index finger resting on the trigger. 2. Squeeze and hold the trigger to activate the scanner. 3. The spotting beam should fall across all bars and the “quiet zone” at each end of the label. A quiet zone is a clean, nonprinted space. Use this drawing as a guide. Quiet Zone

The scan line must cross every bar and space on the symbol.

Quiet Zone

*LABEL* Correct

*LABEL* Incorrect

9560-16U

4-9

Page 72

9560 Transaction Manager User’s Manual

4. For best results, do not scan a label straight on. Aim the scanner as shown. Generally you get the best results with a skew near zero and a pitch near ±20°.

*1

*1

23

23

*

± 2° Dead Zone where specular reflection may occur

*

65°

55°

Skew (Horizontal Reading Angle)

Pitch (Vertical Reading Angle) 9560-17U

Optimum Scanning Optimum scanning angles depend upon the type of the label, the distance from the label, the printing quality, and the lighting of your work area. The optimum scanning distance from the label to the laser scanner varies with the type and length of bar code label and the scanning angle. The optimum distance varies between 3.5 in and 12 in (8.89 cm and 30.48 cm).

4-10

Page 73

Operating the 9560

4

Using the Keypad The 9560 has three keypad options: •

Alphanumeric

•

Numeric

•

Numeric II, large keys

2x40

Code 128 STANDARD

1x20

Code 128 STANDARD

Inte A

Lit rme ton

Co mpa c ny

95 60

Alphanumeric Numeric

Numeric II 9560-46U

4-11

Page 74

9560 Transaction Manager User’s Manual

Function Key Layout Each keypad has 10 programmable function keys. The alphanumeric and numeric/function keypads label the keys F1 through F10. Add your own labels or use the labels included with the 9560 for custom key names. The numeric II keypad with the oversized function keys does not label the keys F1 through F10. The keys do correspond to F1 through F10 as shown in the following drawing. You can customize the function keys with your own labels or the labels included with the 9560.

Layout of Function Keys

F1 F2

F1 F2 F3 F4 F5

F3 F4 F5 F6

F7 F8 F9 F10

F6 F7 F8 F9 F10

Numeric keypad with oversize keys

Alphanumeric and Numeric keypads

9560-41U

All keypads ship with replaceable inserts, and the oversize keypad ships with preprinted labels. You can apply these to meet your applications. You can also use transfer letters or your own labels. For example, you can print function key names from your laser printer and cut them to the same size as the insert.

4-12

Page 75

code39 helconital nugget

5 Data Communications and Operating Options

A F

B

K

G

C

L

H

D

M

I

P U

Q V

R W

E N

J

S

O

X

T Y

C ap s $ 7

/ , Z

4

8

1

5

9

2

6

0

3

B ks p

S pa ce

In

. E n te r te rm

F 1 F 2 F 3 F 4 F 5

F 6 F 7 F 8 F 9

9 F10 5 6 0 ec

Page 76

nugget code39 helconital

Page 77

Data Communications and Operating Options

5

This chapter provides a general overview of data communications and 9560 operating options, such as display settings. For more details, refer to Intermec’s Data Communications Reference Manual.

Introduction to Data Communications Your bar code equipment and data processing equipment (the host computer) must be able to understand and exchange data quickly and accurately. Data communication standards and protocols spell out exactly how data is to be sent and received. This section briefly explains the standards and protocols common to data collection systems.

Data Communications in a Data Collection System The main purpose of bar code data collection is to get data from the warehouse, the shop floor, or the factory to a central database quickly where the information can be processed. To do this, numerous devices transmit and receive data: •

The host computer sends bar code label formats to a bar code label printer.

•

The host computer sends data collection programs through a network controller to the 9560 and other bar code readers.

•

The readers transmit the data collected back to the host computer through a network controller.

The ISO Data Communications Model All Intermec equipment follows the standards established by the International Standards Organization (ISO) to describe the data communications process. The ISO model describes seven, sequential, autonomous layers. For example, the lowest layer, called the physical layer, describes cable connectors, basic signaling, and signal levels used in data communications. The physical layer and the data link layer are the largest layers used by Intermec equipment. For more information on the ISO model and other layers, refer to Intermec’s Data Communications Reference Manual.

5-3

Page 78

9560 Transaction Manager User’s Manual

Physical Layer The physical layer describes the hardware components of data transmission. It sets standards for transmitting voltages and electrical pulses through cables, connectors, and components. Data transmission at the physical layer is defined in these three areas: •

Full-duplex or half-duplex transmission

•

Parallel or serial transmission

•

Asynchronous or synchronous transmission

Transmits and receives data over a single channel, but in one direction at a time. Half-duplex

Transmits and receives data simultaneously over two separate channels within the cable.

Full-duplex

Sends several data bits across the interface together. A group of bits moves over several lines at the same time.

Parallel transmission

Serial transmission Sends data one bit at a time as a series of pulses. Pulses are received in a mark (binary 1), or space (binary 0) condition. The speed of the serial transmission is the baud rate or BPS (bits per second).

You use parallel transmission when the bar code equipment and computers are located within a few feet of each other. Parallel transmission is much faster than serial. However, as data lines get longer, noise and interference on the data lines increase. Requires a start bit to mark the beginning of a data block and a stop bit to mark the end of the data block.

Asynchronous transmission

Uses a clock to determine the exact sending or receiving time for each bit. More than one data character can be sent per frame, and start and stop characters are not included.

Synchronous transmission

Several different interface cables and connectors meet the standards for the physical layer. Each has its own strengths and limitations, depending on the distances between connected devices and the configuration of the equipment. The 9560 supports RS-232, RS-422, and RS-485 multi-drop interfaces. For more information, see Chapter 2, “Preparing to Install the 9560.”

Data Link Layer The data link layer deals with the recognition of data received and the formatting of data transmitted. Protocols guarantee the control and integrity of messages between both ends of a communication link. Communication at this layer is either asynchronous or synchronous.

5-4

Page 79

Data Communications and Operating Options

5

Asynchronous protocols at this level perform error detection. For synchronous protocols, this layer detects starting and ending flags and generates a cyclical redundancy check (CRC). This layer also identifies whether the transmission channel is dedicated (point-to-point) or shared (multipoint), and if transmission is full- or half-duplex.

Full-Duplex Protocols Versus Half-Duplex Protocols At the data link layer, protocols are described as either full-duplex or halfduplex. A full-duplex protocol allows messages to be received and transmitted simultaneously. Your system must have separate, dedicated channels for receiving and transmitting data to use a full-duplex protocol. Also, the host and reader must have the necessary hardware (interrupt structure) to support receiving and transmitting data simultaneously. You define a full-duplex protocol by disabling both the solicitation sequence (Poll and Select) and AFF/NEG handshakes. Point-to-Point and similar user-defined protocols are the only Intermec protocols that are full-duplex. These protocols do not support retransmission of data messages. The reader transmits data when commanded to by the operator, but the reader receives data from the host at any time. A half-duplex protocol requires that only one device transmit data at a time over a shared or dedicated channel. You can use a half-duplex protocol over a full-duplex medium, but only one device at a time can transmit data. You define a half-duplex protocol by defining either the POL character or the AFF character.

Full-Duplex Devices Versus Half-Duplex Devices Devices are full-duplex or half-duplex depending on their ability to receive and transmit data simultaneously. Both hardware and software design determine if a device is full or half-duplex. A full-duplex design requires a hardware UART (universal asynchronous receiver/transmitter) with double-buffered transmit and receive buffers. The UART signals the CPU when a character is received or when the transmit buffer is ready for another character. The software must perform the transmit or receive functions when the UART signals the CPU with an interrupt.

The DLE Character and XON/XOFF Flow Control You use the DLE (data link escape) character to send protocol commands or parameters that you want to be treated as data. The DLE must precede the transparent command or parameter. The following protocol parameters are considered transparent if DLE is enabled: RES, REQ, SOM, TX EOM1, TX EOM2, and XON/XOFF. You can send the DLE, EOR (end of record), and EOF (end of file) characters as data if each is preceded by an DLE.

5-5

Page 80

9560 Transaction Manager User’s Manual

The XON or the XOFF character may match the LRC (Longitudinal Redundancy Check character). If so, the LRC is never checked for transparency. It is always treated as a parameter. Received data is also checked for a DLE. The XON or XOFF character is interpreted as data if XON/XOFF flow control is enabled and the character is preceded by a DLE. In User-Defined protocol, the reader allows flow control to be implemented along with an LRC. The reader knows when the LRC character is expected. It does not perform the XON or XOFF character check when the LRC is the next character expected.

Working With Protocols Data link protocols govern the way data is transmitted. They provide the framework for an orderly exchange of data between computers, terminals, and data collection devices. With most protocols, the reader (slave) never communicates unless the host (master) initiates the transaction with a poll/select sequence. Point-to-Point protocol is the exception. Polling Mode D and Multi-Drop are very secure data link protocols designed to interface with the Intermec 9154 Network Controller and 9161 Port Concentrator. Both devices continuously poll bar code readers and printers for transactions and pass those transactions to the host computer. Both Polling Mode D and Multi-Drop provide recovery from transmission errors (parity and framing errors) and use affirmative and negative responses to verify successful and unsuccessful communication events. If the transmitting device receives a negative acknowledgment, the data is retransmitted. You use User-Defined and User-Defined Multi-Drop protocols to develop a custom protocol. You can define how secure the data link protocol will be and implement a master/slave data link with error recovery.

Point-to-Point Protocol Point-to-Point protocol is designed specifically for Intermec readers where the reader is connected to a terminal or a host computer. Point-to-Point protocol has the following characteristics: This protocol can send and receive data simultaneously.

Full-duplex Asynchronous Nonpolling

The data is sent one character at a time.

The solicitation (POL) and handshake sequences (XON/XOFF) are disabled. Whenever data is available to transmit, the data is transmitted immediately. You can control the flow of data by enabling XON/XOFF or by sending the CTS command (Clear to Send) from the host.

5-6