Page 251

Troubleshooting

10

Status Beeps The reader beeps to indicate its status and condition.

Error Status Beeps Beeps

Error Condition

4 low

Power was applied or unit was reset. RAM and ROM are in proper working condition.

high low high

An input or output error occurred.

1 low

A valid label was read, but not transmitted to the host.

3 low

Invalid data or an invalid command. Clear command was sent when the buffer was already empty. The buffer is full; more than 25 characters in regular operation or 128 characters in Accumulate mode. The CAPS key was pressed.

Adjusting the Beep Volume To adjust the beep volume: Scan the Raise or Lower Beep Volume labels. Lower Beep Volume

*$+BV8$-* *$+BV8$-* Raise Beep Volume

*$+BV9$-* *$+BV9$-*

10-5

Page 252

9560 Transaction Manager User’s Manual

Communications Errors A communications error occurs when the reader fails to complete a transaction with the host. When an error occurs, the reader sounds three beeps (high low high) and displays the error message on the reader display or the CRT terminal. The 9560 displays error messages only when the reader display or the reader terminal port is configured for buffered operation. The table at the end of this section lists some of the most common communications errors and their causes.

Host Communications Failure Two types of errors cause communication failures with the host: Receive errors and Transmit errors. When the host does not receive a transmission, a receive error occurs. You can ignore this error or enter a command. If an error occurred during a transmission to the host, the 9560 saves the data for automatic retransmission. To clear the complete data buffer, use the Clear command. When the host sends a transmission to the reader and a transmit error occurs, the reader does not buffer any more data. The only commands accepted from the scanner or terminal are: •

Clear

•

Transmit No Clear

•

Reset

•

Enter Configuration

•

Enter

•

Review

•

Backspace

•

Forward

•

Set Clock

If you attempt to enter data or other commands, the reader sounds three low beeps.

Maximum Received Data The reader can receive up to 255 data characters from the host (excluding protocol characters). If the host sends more than 255 characters, a host communications failure occurs.

10-6

Page 253

Troubleshooting

10

Maximum Transmitted Data The maximum number of characters transmitted is 215 characters. That is 128 characters for the data, 75 characters for the preambles and postamble, and 12 characters for time. Any protocol characters used during data transmission are not calculated in the maximum. •

The reader has a 128-character data buffer for transmitting completed records to the host. The data buffer holds only one data record.

•

If the preambles or a postamble have been defined, they are transmitted with the data. Each preamble or postamble may be 25 characters. If both preambles and the postamble are defined, then up to 75 characters can be transmitted with the data..

•

If the Append Time to Data parameter is enabled, then the time is transmitted with the data. The appended time is either 10 characters or 12 characters.

Common Errors and Causes Error

Cause

Framing (Transmit or Receive)

Incorrect baud rate or number of data bits.

Parity (Transmit or Receive)

Incorrect parity.

Start of Message (Receive Only)

SOM character not received before data string.

Longitudinal Redundancy Check (Receive Only)

Incorrect LRC character received.

Host Aborted (Transmit or Receive)

RES character received from host while expecting data or handshake response.

Timeout (Transmit or Receive)

Received timeout exceeded.

UART Overflow (Transmit or Receive)

Characters received faster than the reader could process them.

Buffer Overflow (Receive Only)

Characters received faster than the reader could process them, or message longer than 254 characters.

Bad Transmit (Transmit only)

Retry limit exceeded.

10-7

Page 254

This page is a scan with no text; see it in the PDF.

Page 255

code39 helconital nugget

A Specifications

A F

B

K

G

C

L

H

D

M

I

P U

Q V

R W

E N

J

S

O

X

T Y

C ap s $ 7

/ , Z

4

8

1

5

9

2

6

0

3

B ks p

S pa ce

In

. E n te r te rm

F 1 F 2 F 3 F 4 F 5

F 6 F 7 F 8 F 9

9 F10 5 6 0 ec

Page 256

nugget code39 helconital

Page 257

Specifications

A

This appendix lists the hardware and software specifications for the 9560. It includes bar code symbologies, physical and environmental specifications, interfaces, protocols supported, and configuration methods

Bar Code Symbologies Supported Code

Options

CODE 39 HIBC I 2 OF 5

Fixed length (even only) Variable length

2 of 5 UPC/EAN UPC Version E EAN-8

UPC Version A

Codabar

Standard American Blood Commission (ABC) Concatenated

EAN-13 with Supplementals

CODE 11 CODE 93 Code 128

Physical and Environmental Specifications The 9560 Transaction Manager consists of cast aluminum top and bottom covers that house the electronics in a dust- and rain-resistant enclosure. A sheet metal mounting base provides secure installation to either a wall or desk. A connector printed circuit board, mounted outside the sealed enclosure but protected by the case design, contains the relays, sense inputs, 422 drivers and receivers, and the connectors. The case design and the sheet metal mounting plate conceal and protect all of the connectors. 9560 Dimensions Length = 14.4 in (36.6 cm) Width = 3.3 in (8.4 cm) Height = 9.1 in (23.1 cm)

A-3

Page 258

9560 Transaction Manager User’s Manual

Operating Environment Operating temperature range

32°F to 122°F

0°C to +50°C

Storing temperature range

-4°F to 158°F

-20°C to +70°C

Operating humidity

10% to 90% relative humidity

Operator Feedback A cone speaker on the base of the 9560 beeps to indicate status conditions. You program the volume in Configuration mode. The laser scanner is also connected to this speaker line. The laser scanner beeps when the reader does. The 9560 contains an audio output jack for connecting headphones or an external amplifier and speaker.

Communications Settings Baud Rate

Parity

Data Bits

Stop Bits

110

Disabled

7

1

300

Even

8

2

600

Odd

1200

Mark

2400

Space

4800 9600 19200

A-4

Page 259

Specifications

A

Hardware Interfaces Port

Interface

Connectors

Modem

RS-232-C RS-422

25-Pin, D-subminiature, wired as DTE

Terminal

RS-232-C RS-422

Connector: 25-Pin, D-subminiature, wired as DCE

Pin Assignments for 6-Pin Wand Connector Pin

Signal

Direction

1

+12V

2

+5V

3

Ground

4

Ground

5

Video

Incoming

6

Serial Out

Outgoing

Pin Assignments for 9-Pin Laser Scanner Connector Pin

Signal

Direction

1

Trigger

Incoming

2

Video

Incoming

3

LED

Outgoing

4

Beeper

Outgoing

5

Laser Enable

Outgoing

6

Start of Scan

Incoming

7

Shield

8

+5V (1.8A maximum)

9

Ground

A-5

Page 260

9560 Transaction Manager User’s Manual

Pin Assignments for 25-Pin Modem Connector Pin

Signal

Direction

1

Chassis Ground

(optional)

2

Transmitted Data

Outgoing

3

Received Data

Incoming

4

Request to Send

Outgoing

5

Clear to Send

Incoming

7

Signal Ground

(required)

11

Remote Triggering

(when enabled)

13

Received Data B

Incoming

14

Transmitted Data A

Outgoing

16

Received Data A

Incoming

19

Transmitted Data B

Outgoing

20

Data Terminal Ready

Outgoing

Pin Assignments for 25-Pin Terminal Connector

A-6

Pin

Signal

Direction

1

Chassis Ground

(optional)

2

Transmitted Data

Incoming

3

Received Data

Outgoing

4

Request to Send

Incoming

5

Clear to Send

Outgoing

7

Signal Ground

(required)

11

Remote Triggering

(when enabled)

13

Received Data B

Outgoing

14

Transmitted Data A

Incoming

16

Received Data A

Outgoing

19

Transmitted Data B

Incoming