Page 251
Troubleshooting
10
Status Beeps The reader beeps to indicate its status and condition.
Error Status Beeps Beeps
Error Condition
4 low
Power was applied or unit was reset. RAM and ROM are in proper working condition.
high low high
An input or output error occurred.
1 low
A valid label was read, but not transmitted to the host.
3 low
Invalid data or an invalid command. Clear command was sent when the buffer was already empty. The buffer is full; more than 25 characters in regular operation or 128 characters in Accumulate mode. The CAPS key was pressed.
Adjusting the Beep Volume To adjust the beep volume: Scan the Raise or Lower Beep Volume labels. Lower Beep Volume
*$+BV8$-* *$+BV8$-* Raise Beep Volume
*$+BV9$-* *$+BV9$-*
10-5
Page 252
9560 Transaction Manager User’s Manual
Communications Errors A communications error occurs when the reader fails to complete a transaction with the host. When an error occurs, the reader sounds three beeps (high low high) and displays the error message on the reader display or the CRT terminal. The 9560 displays error messages only when the reader display or the reader terminal port is configured for buffered operation. The table at the end of this section lists some of the most common communications errors and their causes.
Host Communications Failure Two types of errors cause communication failures with the host: Receive errors and Transmit errors. When the host does not receive a transmission, a receive error occurs. You can ignore this error or enter a command. If an error occurred during a transmission to the host, the 9560 saves the data for automatic retransmission. To clear the complete data buffer, use the Clear command. When the host sends a transmission to the reader and a transmit error occurs, the reader does not buffer any more data. The only commands accepted from the scanner or terminal are: •
Clear
•
Transmit No Clear
•
Reset
•
Enter Configuration
•
Enter
•
Review
•
Backspace
•
Forward
•
Set Clock
If you attempt to enter data or other commands, the reader sounds three low beeps.
Maximum Received Data The reader can receive up to 255 data characters from the host (excluding protocol characters). If the host sends more than 255 characters, a host communications failure occurs.
10-6
Page 253
Troubleshooting
10
Maximum Transmitted Data The maximum number of characters transmitted is 215 characters. That is 128 characters for the data, 75 characters for the preambles and postamble, and 12 characters for time. Any protocol characters used during data transmission are not calculated in the maximum. •
The reader has a 128-character data buffer for transmitting completed records to the host. The data buffer holds only one data record.
•
If the preambles or a postamble have been defined, they are transmitted with the data. Each preamble or postamble may be 25 characters. If both preambles and the postamble are defined, then up to 75 characters can be transmitted with the data..
•
If the Append Time to Data parameter is enabled, then the time is transmitted with the data. The appended time is either 10 characters or 12 characters.
Common Errors and Causes Error
Cause
Framing (Transmit or Receive)
Incorrect baud rate or number of data bits.
Parity (Transmit or Receive)
Incorrect parity.
Start of Message (Receive Only)
SOM character not received before data string.
Longitudinal Redundancy Check (Receive Only)
Incorrect LRC character received.
Host Aborted (Transmit or Receive)
RES character received from host while expecting data or handshake response.
Timeout (Transmit or Receive)
Received timeout exceeded.
UART Overflow (Transmit or Receive)
Characters received faster than the reader could process them.
Buffer Overflow (Receive Only)
Characters received faster than the reader could process them, or message longer than 254 characters.
Bad Transmit (Transmit only)
Retry limit exceeded.
10-7
Page 254
Page 255
code39 helconital nugget
A Specifications
A F
B
K
G
C
L
H
D
M
I
P U
Q V
R W
E N
J
S
O
X
T Y
C ap s $ 7
/ , Z
4
8
1
5
9
2
6
0
3
B ks p
S pa ce
In
. E n te r te rm
F 1 F 2 F 3 F 4 F 5
F 6 F 7 F 8 F 9
9 F10 5 6 0 ec
Page 256
nugget code39 helconital
Page 257
Specifications
A
This appendix lists the hardware and software specifications for the 9560. It includes bar code symbologies, physical and environmental specifications, interfaces, protocols supported, and configuration methods
Bar Code Symbologies Supported Code
Options
CODE 39 HIBC I 2 OF 5
Fixed length (even only) Variable length
2 of 5 UPC/EAN UPC Version E EAN-8
UPC Version A
Codabar
Standard American Blood Commission (ABC) Concatenated
EAN-13 with Supplementals
CODE 11 CODE 93 Code 128
Physical and Environmental Specifications The 9560 Transaction Manager consists of cast aluminum top and bottom covers that house the electronics in a dust- and rain-resistant enclosure. A sheet metal mounting base provides secure installation to either a wall or desk. A connector printed circuit board, mounted outside the sealed enclosure but protected by the case design, contains the relays, sense inputs, 422 drivers and receivers, and the connectors. The case design and the sheet metal mounting plate conceal and protect all of the connectors. 9560 Dimensions Length = 14.4 in (36.6 cm) Width = 3.3 in (8.4 cm) Height = 9.1 in (23.1 cm)
A-3
Page 258
9560 Transaction Manager User’s Manual
Operating Environment Operating temperature range
32°F to 122°F
0°C to +50°C
Storing temperature range
-4°F to 158°F
-20°C to +70°C
Operating humidity
10% to 90% relative humidity
Operator Feedback A cone speaker on the base of the 9560 beeps to indicate status conditions. You program the volume in Configuration mode. The laser scanner is also connected to this speaker line. The laser scanner beeps when the reader does. The 9560 contains an audio output jack for connecting headphones or an external amplifier and speaker.
Communications Settings Baud Rate
Parity
Data Bits
Stop Bits
110
Disabled
7
1
300
Even
8
2
600
Odd
1200
Mark
2400
Space
4800 9600 19200
A-4
Page 259
Specifications
A
Hardware Interfaces Port
Interface
Connectors
Modem
RS-232-C RS-422
25-Pin, D-subminiature, wired as DTE
Terminal
RS-232-C RS-422
Connector: 25-Pin, D-subminiature, wired as DCE
Pin Assignments for 6-Pin Wand Connector Pin
Signal
Direction
1
+12V
2
+5V
3
Ground
4
Ground
5
Video
Incoming
6
Serial Out
Outgoing
Pin Assignments for 9-Pin Laser Scanner Connector Pin
Signal
Direction
1
Trigger
Incoming
2
Video
Incoming
3
LED
Outgoing
4
Beeper
Outgoing
5
Laser Enable
Outgoing
6
Start of Scan
Incoming
7
Shield
8
+5V (1.8A maximum)
9
Ground
A-5
Page 260
9560 Transaction Manager User’s Manual
Pin Assignments for 25-Pin Modem Connector Pin
Signal
Direction
1
Chassis Ground
(optional)
2
Transmitted Data
Outgoing
3
Received Data
Incoming
4
Request to Send
Outgoing
5
Clear to Send
Incoming
7
Signal Ground
(required)
11
Remote Triggering
(when enabled)
13
Received Data B
Incoming
14
Transmitted Data A
Outgoing
16
Received Data A
Incoming
19
Transmitted Data B
Outgoing
20
Data Terminal Ready
Outgoing
Pin Assignments for 25-Pin Terminal Connector
A-6
Pin
Signal
Direction
1
Chassis Ground
(optional)
2
Transmitted Data
Incoming
3
Received Data
Outgoing
4
Request to Send
Incoming
5
Clear to Send
Outgoing
7
Signal Ground
(required)
11
Remote Triggering
(when enabled)
13
Received Data B
Outgoing
14
Transmitted Data A
Incoming
16
Received Data A
Outgoing
19
Transmitted Data B
Incoming