The text of a manual · part 22 of 31
9560 Transaction Manager User's Manual, pages 211 to 220
Pages 211 to 220 of 309
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9560
Page 211
Data Entry Commands - Exit Configuration Mode, Do Not Save Settings
8
Exit Configuration Mode, Do Not Save Settings Purpose:
Exits Configuration mode without updating the parameters.
Terminal / Keyboard
Ctrl Z
Host:
-.
Scan:
Exit Configuration Mode No Save
*-.* * - .*
Exit Configuration Mode, Save Settings Purpose:
Exits Configuration mode and saves current configuration settings. Saves all Data Entry command settings.
Terminal / Keyboard
Esc
Host:
$ -
Scan:
Exit Configuration Mode, Save Settings
*$-* *$ - *
8-17
Page 212
Data Entry Commands - Exit Full ASCII Mode
Exit Full ASCII Mode Purpose:
Exits Full ASCII mode and decodes full ASCII characters as Code 39 data.
Terminal / Keyboard
Ctrl Q
Host:
- $
Scan:
Exit Full ASCII
*-$* * - $*
Exit IRL Editor Purpose:
Exits the regular CRT-based IRL editor.
Terminal / Keyboard
Q Enter
Host:
Not Applicable
Scan:
Exit IRL Editor
*/$* */$*
8-18
Page 213
Data Entry Commands - Exit Program
8
Exit Program Purpose:
Interrupts an IRL program. The program is not resumed.
Terminal:
Not Applicable
Keyboard:
Ctrl-Enter [E] Note: Simultaneously press Ctrl and Enter, and then press E.
Host:
/$
Scan:
Exit Program
*/$* */$*
Forward Purpose:
Scrolls the display down one row in the current virtual display image (after a review command has moved the display up).
Terminal:
Not Applicable
Keyboard:
á
Host:
Not Applicable
Scan:
Forward
*%+* *%+*
8-19
Page 214
Data Entry Commands - High Beep
High Beep Purpose:
Generates a high beep when the computer sends a backslash character (\). Multiple \’s cause multiple high 60 msec beeps with a 45 msec delay between beeps. High and low beeps can be intermixed.
Terminal / Keyboard
Not Applicable
Host:
\
Scan:
Not Applicable
Laser Trigger Purpose:
Turn the laser on.
Terminal / Keyboard
Not Applicable
Host:
/.
Scan:
Not Applicable
8-20
Page 215
Data Entry Commands - Laser Untrigger
8
Laser Untrigger Purpose:
Turns the laser off.
Terminal / Keyboard
Not Applicable
Host:
/%
Scan:
Not Applicable
8-21
Page 216
Data Entry Commands - LED/Relay Control
LED/Relay Control Purpose:
Controls the four status LEDs of an attached 9191 Digital Wand Station and the three internal relays of the 9560. Also returns the status of the sense inputs to the #0 register. You can enter up to eight valid data characters. This command is specific to the 9560. Valid data characters are: 0 = turn LED/relay off 1 = turn LED/relay on X = default LED function or no change to current state The command syntax is: $%char1 char2...char8 Character
LED/Relay
1st 2nd 3rd 4th 5th 6th 7th 8th
Configuration LED Fault LED Wait LED Good Read LED 1st relay 2nd relay 3rd relay Reserved
The relays retain their states from the last LED/Relay command until the next LED/Relay command. A power on or off reset turns the relays off and they stay off until an LED/Relay Control command turns them on. When the LED/Relay Control command is executed, the status of the sense inputs is returned to the #0 register. For more information, see “9560-Unique IRL Commands” in Chapter 9, “Interactive Reader Language.” Terminal / Keyboard
Not Applicable
Host:
$%dataX
8-22
Page 217
Data Entry Commands - LED/Relay Control
Scan:
8
All Relays On, LEDs to Default
*$%XXXX111X* *$%XXXX111X*
All Relays Off, LEDs to Default
*$%XXXX000X* *$%XXXX000X*
8-23
Page 218
Data Entry Commands - Low Beep
Low Beep Purpose:
Generates a low beep when the computer sends a BEL. Multiple BELs cause multiple 60 msec low beeps with a 45 msec delay between beeps. High and low beeps can be intermixed.
Terminal / Keyboard
Not Applicable
Host:
Ctrl G or BEL
Scan:
Not Applicable
8-24
Page 219
Data Entry Commands - Preamble A
8
Preamble A Purpose:
Enters up to 25 characters into the Preamble A buffer to be transmitted with the data. For an explanation of preambles, see Chapter 5, “Data Communications and Operating Options.” If you enter the Preamble A command without entering data, then the preamble buffer is cleared. If you enter a single space or you enter data from the terminal, all subsequent data is stored in the preamble buffer until you send the Enter command (**) or until the buffer overflows.
Terminal / Keyboard
Ctrl A data Enter Ctrl A Enter
Host:
+.data+.
Scan:
To enter Preamble A: 1. Scan this label: Enter Preamble A
*+. *
*+. *
2. Scan up to 25 characters from the full ASCII chart in appendix B, “Full ASCII Chart.” 3. Scan this label: Enter
** **
Or:
To clear Preamble A, scan this label: Clear Preamble A
*+.* *+.*
8-25
Page 220
Data Entry Commands - Preamble B
Preamble B Purpose:
Enters up to 25 characters into the Preamble B buffer to be transmitted with the data. For an explanation of Preambles, see Chapter 5, “Data Communications and Operating Options.” If you enter the Preamble B command without entering data, then the preamble buffer is cleared. If you enter a single space or you enter data from the terminal, all subsequent data is stored in the preamble/postamble buffer until you send the Enter command (**) or until the buffer overflows.
Terminal / Keyboard
Ctrl B data Enter Ctrl B Enter
Host:
++data++
Scan:
To enter Preamble B: 1. Scan this label: Enter Preamble B
*++* *++*
2. Scan up to 25 characters from the full ASCII chart in Appendix B, “Full ASCII Chart.” 3. Scan this label: Enter
** **
Or:
To clear Preamble B, scan this label: Clear Preamble B
*++* *++*
8-26