Page 251
HelvC NugFont
Co d e 39 Glossary
G
UPC/EAN code A fixed length, numeric, continuous bar code symbology that uses four element widths. A terminal that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. It is a numeric, 12-digit bar code symbology used extensively in retail, particularly the grocery industry. The character set is 0 to 9. Its maximum character density is 13.8 numeric characters per inch. upline A device that is at the computer end of a connection between a computer and a device is referred to as being upline. When devices are connected to a computer, they are connected in a line. Upline is a direction relative to the device, in contrast to downline. If more than one computer is connected in a line, the upline computers usually handle data processing and the downline computers usually handle data collection and sometimes data preprocessing.
variable length A type of symbology in which the number of characters per symbol is not restricted. Opposite of fixed length. Version A Standard 12-digit UPC symbol. Version E Special 6-digit shortened UPC code that requires less space and uses zero suppression. viewport A method for viewing a full size terminal screen (25 lines x 80 characters) with the terminal’s 16 x 20 display. You will only see 16 lines and 20 characters of data at one time. Use the terminal’s display as a viewport to move around and see the entire screen. VMU A Vehicle Mount Unit. A device that is designed to be mounted on a vehicle, such as the J2050. volatile Refers to memory that is not saved when power is lost or turned off.
G-29
Page 252
IRL Programming Reference Manual HelvC NugFont Co d e 39 wedge reader A bar code reader that connects between the keyboard and the terminal of a personal computer. The reader allows you to enter information into the computer by scanning bar code labels. wide to narrow ratio The comparison of the widest bar in a bar code symbol to the narrowest bar. Expressed as a ratio such as 2:1 or 2.5:1. X-dimension The width of the narrowest element in a bar code symbol. An element can be a bar or a space. XMODEM A protocol that allows you to send commands to and communicate through a modem. XOFF Defines a character that disables the transmission event. The receiving device sends XOFF when its receive buffers are nearly full of data. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. XON Enables or disables XON/XOFF flow control and defines a character that reenables transmission when the device can receive data again after an XOFF. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. XON/XOFF A type of software flow control for communication between digital devices. It stops the host from sending data when the device buffer fills up (XOFF) and starts it again when the buffer empties (XON).
G-30
Page 253
nugget code39 helconital
I Index
Page 254
nugget code39 helconital
Page 255
Index
I
Index Symbols #n command (Monitor), 4-21 $n command (Monitor), 4-21 / (backslash) character, 6-4 . (Label) command, 2-15, 3-23, 7-6 : (Comment) command, 2-14, 3-22, 7-7 [ ] in commands, 7-3 [F(n)], 7-14 {IRL-0}.IRD, 5-9 {IRL-1}.IRL, 5-9 {IRL-A}.IRD, 5-9
Numbers 9450 Vehicle-Mount Unit, 1-4 94XX and JANUS differences, 5-18 94XX TRAKKER, 1-4 9512 Transaction Manager, 1-4 9550 Transaction Manager, 1-4 9560 relays, 7-19 9560 Transaction Manager, 1-4
A A command, 2-7, 3-12, 7-8 allocating memory, 3-6 alphanumeric input, See A command appending data, 3-13, 3-18, 7-24 appending date and time, 3-14, 7-43 ASCII control characters, 3-10, 6-4, 6-9, A-3 ASCII Input command, 2-7, 7-8 assigning values to variables, 7-14 AUTOEXEC.BAT, 5-16 available memory, 3-6
B B command, 2-16, 3-16, 7-11 backslash character, 3-10, 6-4 backslash sequence, 2-15, 3-10, 6-4, 7-36, 7-51, 7-53 bar code readers supported, 1-4 bar codes for running and exiting IRL programs, 1-7 battery status, 5-13, 7-19 baud rate, 2-24, 4-5 Beep command, 2-16, 3-16, 7-11 binary data, 6-9 binary search, 6-7, C-3 blank spaces, 2-6, 3-10 blinking display, 5-15, 7-36 booting the reader, 5-16 brackets [ ] in commands, 7-3 branching to a label, 7-21 branching to a subroutine, 3-23, 7-41 BS character, 6-4 buffer, input, 6-9, 6-10, 6-11 Buffered display mode, 7-37
C C command, 2-23, 3-5, 3-18, 7-12 Call Subroutine command, 2-21, 7-41 calling a subroutine, 7-41 carriage return character, 3-10 changing reader protocol, 7-51 characters, ASCII control, 3-10, A-3 checking battery status, 5-13 Clear to Send signal, 6-10 clock, setting, 3-14, 5-14, 7-43 command descriptions .label, 7-6 : Comment, 7-7 A, 7-8 B, 7-11 C, 7-12 D, 7-14 E, 7-17 F, 7-19 G, 7-21 H, 7-23 I, 7-24 K, 7-26 L, 7-29 N, 7-31 O, 7-33 P, 7-36 Q, 7-38 R, 7-40 S, 7-41 T, 7-43 U, 7-45 V, 7-47 W, 7-49 X, 7-50 Y, 7-53 Z, 7-56 commands data manipulation, 3-16 description, 7-3 Enter IRL Editor command, 4-4, 4-5 input, 3-12
I-3
Page 256
IRL Programming Reference Manual commands, continued IRL Editor, 4-3, 4-10 IRL Monitor, 4-17 list of IRL commands, 3-11, 7-5 output, 3-15 program control, 3-22 Comment command, 2-14, 3-22, 7-7 comments, 3-22 communicating with a host, 6-9 communications buffer, 5-18 communications protocol, 2-24 compile errors, 4-8 messages, B-10 compiling programs, 4-8 concatenation, 3-21, 7-15 conditional commands, 2-16 configuring a reader with Z commands, 5-13 control characters, 2-15, 3-10, 7-36, 7-51, 7-53, A-3 conventions for command descriptions, 7-3 for this manual, xv Convert command, 2-23, 3-5, 3-18, 7-12 converting data floating point to string, 3-18, 7-13 numeric to string, 3-18, 7-12 string to numeric, 3-18, 7-12 Copy Left command, 7-15 Copy Middle command, 7-15 Copy Right command, 7-15 copying data to a DOS file, 7-50 copying data to a file, 7-40 CTS signal, 6-10
D D command, 2-16, 2-17, 2-22, 3-19, 7-14 data appending, 3-18, 7-24 converting, 3-18 storing, 7-40 transferring to a file, 3-17 data files, 3-7, 3-8, 5-9 data input limits, 6-9 Data Link Exception character, 6-12 data manipulation commands, 3-16 C, 7-12 D, 7-14 O, 7-33 data mask, 7-8, 7-21, 7-26, 7-29, 7-38, 7-41 data transfer, 6-10 date and time, 7-43 date, appending, 5-16 day of year, 5-16 default program file, 3-7 Define Data command, 2-16, 2-17, 2-22, 3-19, 7-14
I-4 defined terms, xv, G-3 Delete command (Editor), 4-11 designated files, 3-7, 3-8, 3-17 determining next available record, 3-25 dimensioned data files, 5-10 display blinking, 5-15, 7-36 preventing flicker, 6-6 prompts, 2-7, 3-15, 5-15, 7-36 reverse video, 5-15, 7-36 writing to, 2-7, 3-15, 7-36 Display File Command (Monitor), 4-18 displaying input and prompts, 7-36 DLE character, 6-12 DOS Attrib command, 5-17 DOS text editor, 1-7 download error messages, B-12
E E command, 2-8, 3-24, 7-17 edited input, 3-12 Editor, IRL, See also IRL Editor exiting, 4-11 exiting without compiling, 4-15 End command, 2-8, 3-24, 7-17 End Command (Editor), 4-11 Enter IRL Editor command, 4-4, 4-5 Enter key (IRL Monitor), 4-18 Enter Monitor Command (Editor), 4-14 environment variable for EOF, 5-16 EOF character, 5-16 EOM character, 6-10 error messages alphabetical list, B-3 compile, B-10 IRL Editor, B-9 IRL Monitor, B-9 download, B-12 runtime, B-11 syntax, B-7 Errors compile, 4-8 compiling, 4-8 fatal, 4-9 nonfatal, 4-9 runtime, 4-8 escape sequence, 7-36 Execute Command (Monitor), 4-18 Execute Reader Command command, 2-24, 3-25, 7-56 executing Reader commands within a program, 3-25 Exit Command (Monitor), 4-18 exiting a program, 1-7, 3-24, 7-17 exiting a subroutine, 7-38
Page 257
nugget
F F command, 3-16, 5-13, 7-19 fatal errors, 4-9 file naming conventions, 5-9 file pointer, 7-23 File Position command, 2-22, 2-25, 3-25, 7-23 file, default program, 3-7 filenames for JANUS readers, 5-9 files AUTOEXEC.BAT, 5-16 data, 3-7, 3-8, 5-9 IRL.BAT, 5-16 opening, 3-17 receiving, 6-11 transmitting, 6-12 Find Command (Editor), 4-12 Find Command (Monitor), 4-19 floating point registers, 3-5, 3-20, 5-16 format conventions, 7-3 Function keys, 3-26, 5-18 Function Output command, 3-16, 5-13, 7-19
G G command, 2-16, 3-23, 7-21 Glossary, G-3 Goto command, 2-16, 3-23, 7-21 Goto command (Monitor), 4-20 guidelines for programming, 2-6
H H command, 2-22, 2-25, 7-23 hexadecimal, 2-15, 3-10, A-3 hexadecimal numbers, convention for, xvii host port, 6-10, 6-11 HT character, 6-4
I I command, 2-8, 3-18, 7-24 I/O devices, 3-8 input and output, 3-8 input buffer, 6-9, 6-10, 6-11 purging, 6-11 input commands, 3-12 A, 7-8 I, 7-24 K, 7-26 N, 7-31 U, 7-45 V, 7-47 Y, 7-53 input register, 3-13 Insert command, 2-8, 3-18, 4-13, 7-24 inserting data, 3-13, 3-18, 7-24 code39 helconital Index
I insufficient memory, 5-12 IRL command descriptions, 7-3 command list, 3-11, 7-5 definition, 1-3 files, 5-9 location, 3-4 See also Command Descriptions IRL Desktop, 5-4, 5-12 IRL Editor, 4-4, 4-10 IRL Editor commands D (Delete), 4-11 E (End), 4-11 F (Find), 4-12 I (Insert), 4-13 L (List), 4-14 M (Enter Monitor), 4-14 Q (Quit), 4-15 S (Substitute), 4-15 U (Usage), 4-16 CRT Editor error messages, B-9 IRL Monitor, 4-4, 4-9, 4-17 IRL Monitor commands #n (Redefine Numeric), 4-21 $n (Redefine String), 4-21 D (Display File), 4-18 E (Exit), 4-18 Execute, 4-18 F (Find), 4-19 G (Goto), 4-20 L (List), 4-20 Q (Quit), 4-20 R (Register), 4-21 IRL Monitor error messages, B-9 IRL prompts and input, 5-15 IRL version 2.X, xiii, 1-4, 3-4, 7-4 IRL version 4.X, xiii, 1-4, 3-4, 5-3, 7-4 IRL version differences, 1-4, 3-4, 7-4 IRL Z command, 7-56 IRL.BAT, 5-16
J JANUS 2010, 1-4 JANUS 2020, 1-4 JANUS 2050, 1-4 JANUS and 94XX differences, 5-18 JANUS reader commands, 5-19 jumping to a specific program statement, 7-21 jumping to a subroutine, 7-41
K K command, 7-26 Keyboard Input command, 3-13, 7-26 keyboard, using, xvi
I-5
Page 258
IRL Programming Reference Manual keypad, using, xvi keys, function, 3-26, 5-18
L L command, 3-25, 7-29 Label command, 2-15, 3-23, 7-6 learning to program, 2-3 LED status, 3-16, 7-19 Left Copy command, 7-15 line feed character, 3-10 List Command (Editor), 4-13 List Command (Monitor), 4-20 Longitudinal Redundancy Check (LRC), 7-34 Lookup Record command, 3-25, 7-29
M manual organization, xiv reading path, xv manuals, other Intermec, xviii mask, 7-8, 7-21, 7-26, 7-29, 7-38, 7-41 mathematical operations, 3-19 memory calculating amount reserved, 7-33, 7-34 for program files, 3-6 insufficient, 5-12 message, protected field, 5-14, 6-6 Middle Copy command, 7-15 modem data transfer, 6-10 secure protocol, 6-11 modem program, C-7 Monitor, IRL, See IRL Monitor. See IRL Monitor Multi-read reader commands, 7-45
N N command, 2-8, 7-31 naming files on JANUS readers, 5-9 new line character, 3-10 no protocol modifier, 5-18 nonfatal errors, 4-9 NUL character, 6-4 Numeric Input command, 2-8, 3-13, 7-31 numeric registers, 3-5, 3-19 limits, 3-18, 3-19
O O command, 2-21, 3-7, 3-8, 7-33 Open command, 2-21, 3-7, 3-8, 3-17, 7-33 opening a data file, 2-21, 7-33 output commands, 3-15 B, 7-11 F, 7-19 P, 7-36
I-6
R, 7-40 T, 7-43 X, 7-50
P P command, 2-7, 3-15, 5-15, 7-36 path for IRL files on JANUS readers, 5-11 pauses, 3-25, 7-49 PC Standard protocol, 5-18, 7-52, 7-55 PC-IRL, 2-5 position in data file, 3-25 power management, 5-13 pressing keys in a sequence, xvi program bar codes for running and exiting, 1-7 exiting, 3-24 program control commands, 3-22 .label, 7-6 : Comment, 7-7 E, 7-17 G, 7-21 H, 7-23 L, 7-29 P, 7-38 S, 7-41 W, 7-49 Z, 7-56 program jump, 7-21 Program One listing, 2-7 Program Three listing, 2-19 Program Two listing, 2-14 programming methods, 2-5 on a host computer, 1-6 on a JANUS reader, 1-7 on a reader, 1-6 on an attached terminal, 1-6 with a DOS text editor, 1-7 with PC–IRL, 1-5 programming guidelines, 2-6 programming statements, 1-3, 3-9, 3-10 Prompt command, 2-7, 3-15, 5-15, 7-36 protected field message, 5-14, 6-6 protocol receiving data, 7-53 transmitting data, 7-51 protocol handler, 7-52, 7-55 purging the input buffer, 6-11
Q Q command, 7-38 Quit Command (Editor), 4-15 Quit Command (Monitor), 4-20 Quit Subroutine command, 7-38
Page 259
nugget quitting a program, 7-17 quitting a subroutine, 7-38 quotation marks, 3-16, 7-24, 7-36
R R command, 2-8, 3-17, 7-40 reader commands for JANUS, 5-19 reader configuration commands, 3-9, 5-13 reader types, 1-4 reader, IRL versions, 1-4 readers supported, 1-4 Receive Data command, 3-14, 7-53 receiving files, 6-11 Record command, 2-8, 3-17, 7-40 record location, 7-23 record, determining next available, 3-25 records, transmitting, 6-12 Redefine Numeric Command (Monitor), 4-21 Redefine String Command (Monitor), 4-21 Register Command (Monitor), 4-21 registers floating point, 3-4, 3-5, 3-20, 5-16 numeric, 3-4, 3-5, 3-19 status, 3-5 string, 3-4, 3-5, 3-20 relays on the 9560, 7-19 resuming a program, 1-7, 5-12 retreiving the file position pointer, 7-23 reverse video display, 5-15, 7-36 Right Copy command, 7-15 run an IRL program, 1-7 runtime error messages, B-11
S S command, 2-21, 7-41 sample program binary search, C-3 TRAKKER modem, C-7 Sample Program One, 2-6 Sample Program Three, 2-18 Sample Program Two, 2-13 searching, binary search, 6-7, C-3 seconds since midnight, 5-16 Set Clock reader command, 7-43 setting the: file position pointer, 7-23 clock, 3-14, 7-43 JANUS clock, 3-14, 5-14, 7-43 time and date, 3-14, 7-43 special characters, 3-10, A-3 status codes, 7-9, 7-12, 7-27, 7-31, 7-45, 7-47, 7-48, 7-51, 7-54 status lights, 3-16, 7-19 code39 helconital Index
I storing data, 7-40 string functions, 3-21, 7-14 string length function, 7-14 string registers, 3-5, 3-20 appending data, 3-13 clearing, 3-5 math functions, 3-21 working with, 3-20, 3-21 strings copying, 7-15, 7-40 searching for, 3-25 string functions, 3-21, 7-14 subroutine calling, 7-41 defined, 3-23 introduced, 2-20 labelling, 7-6 Substitute Command (Editor), 4-15 Suspend mode, 5-12 syntax error messages, B-7
T T command, 2-15, 3-14, 5-16, 7-43 termination character, 7-55 terms and conventions, xv time, setting, 3-14, 5-14, 7-43 Time command, 2-15, 3-14, 5-16, 7-43 timeout, 5-18 tips for using IRL, 6-3 TRAKKER, 6-5 TRAKKER 40 MD modem, C-7 transferring data to a file, 3-17 Transmit Data command, 2-24, 3-16, 6-12, 7-50 transmitting EOF, 5-16 transmitting files, 6-12 transmitting records, 6-12 Transparent display mode, 6-5, 7-37 tutorial, 2-3
U U command, 3-13, 7-45 unconditional commands, 2-16 undimensioned data files, 5-10 Unedited Input command, 3-13, 7-45 Universal Input command, 2-24, 3-13, 7-47 Usage Command (Editor), 4-16 user tips, 6-3 using quotation marks, 3-16
V V command, 2-24, 3-13, 7-47 versions of IRL, xiii
I-7
Page 260
IRL Programming Reference Manual
W
X
W command, 2-17, 3-25, 7-49 Wait command, 2-17, 3-25, 7-49 warranty information, ii, xiii wild card characters, 7-8, 7-21, 7-26, 7-29, 7-38, 7-41 writing JANUS programs, 1-7 writing to the display, 2-7, 3-15
X command, 2-24, 3-16, 7-50 Xmodem protocol, C-7
Y Y command, 3-14, 7-53
Z Z command, 2-24, 3-9, 3-25, 5-13, 5-18, 6-6, 7-56
I-8