Page 241

HelvC NugFont

Co d e 39 Glossary

G network A collection of devices that can store and manipulate electronic data, interconnected in such a way that their users can store, retrieve, and share information with each other. network node An end point in a network to which or from which data can be routed. Usually this is a workstation or host computer. nonvolatile Refers to memory that is saved when power is lost or turned off. NUL ASCII control character representing NULL or all zeros. null modem cable A cable that connects two computers and allows transmission of data between them without requiring a modem. One-Shot mode See Scanner mode. OSI model Open Systems Interconnection reference model. A model for network communications consisting of seven layers that describe what happens when computers communicate with one another. The OSI model was developed by the International Standards Organization (ISO) to provide worldwide standards for computer communications. packet The unit of information that the network uses to communicate. A packet includes a single network message with its associated header, addressing information, data, and optional trailer. A packet can also be called a frame or datagram. PAK Program Acknowledgment character. Sent from the reader when the received IRL program compiles with no errors. parameter See configuration command.

G-19

Page 242

IRL Programming Reference Manual HelvC NugFont Co d e 39 parity A system for encoding characters with odd or even patterns. Parity provides a self-checking feature in bar codes and other data transmission techniques. For the purposes of data processing and data communications, parity does not relate to whether the original character is odd or even, but how an individual character is made odd or even with the addition of one more bit (1 or 0). parity bit A parity bit is added to the binary array to make the sum of all of the bits always odd or always even for a fundamental check. PDF 417 A two-dimensional stacked symbology. Each row in the symbol includes start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. PDF 417 provides an extensive error detection and correction option that can recover up to 510 characters lost due to a damaged label or to an error in scanning. peer-to-peer network A type of LAN whose workstations are capable of being both clients and servers. Plessey code A fixed length, continuous, and non self-checking bar code symbology. Plessey code is pulse-width modulated. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. Similar to MSI code. Point-to-Point Protocol Communications protocol typically used to connect the reader directly to a computer or terminal. Data sent by the reader is followed by a carriage return and line feed (CR LF). XON/XOFF is supported. Point-to-Point protocol characters cannot be modified; however, the transmission parameters, such as parity and data bits, can be modified. POL Poll character. Sent by the host to request reader data. For User Defined MultiDrop protocol, you must define a unique character for each reader on a data line. poll sequence A controller command to a polled device that tells the device to send data.

G-20

Page 243

HelvC NugFont

Co d e 39 Glossary

G polled device A device in a network that transmits data in response to an initialization from the controller. If the POL character is not enabled, all Intermec readers and printers will transmit data when the operating system of the device requires data to be transmitted. polling The act of a computer (or controller) asking end devices if they have information to send to the computer (or controller.) Polling Mode D Polling Mode D is a protocol that allows devices and controllers to exchange data in an ask and receive format. Polling Mode D is used to connect multiple devices to a single multiport controller.· Communications protocol for connecting the reader to a 9160A or 9161A Port Concentrator or a 9165B System Control Unit. Polling Mode D operates only at 2400 baud or higher and cannot be modified. port For hardware, a connecting component that allows a microprocessor to communicate with a peripheral device. For software, a memory address that identifies the physical circuit used to transfer information between a microprocessor and a peripheral device. postamble A field of data that is sent after the data in a message. It is typically used to tag transactions from the bar code reader or terminal for rapid processing by the host, and it expands the data field (record) length. Similar to the preamble. power management Software and procedures that extend the life of a reader’s lithium-ion main battery pack and NiCad backup battery. preamble Predefined data that is automatically appended to the beginning of entered data. Similar to the postamble. protected field On a display device, a display field in which a user cannot enter, modify, or erase data. protocol character See ASCII control character.

G-21

Page 244

IRL Programming Reference Manual HelvC NugFont Co d e 39 protocol stack A group of drivers that work together to span the layers in the network protocol hierarchy. PSS Program Statement Separator character. The PSS indicates the end of an IRL program statement. It separates individual IRL program statements from one another in a block of IRL program statements. PSS must not be defined same as the EOM. quiet zone The area on a bar code label immediately preceding the start character and following the stop character that contains no markings and is free of any extraneous marks. It is quiet in terms of the scanning signal produced. radio frequency (RF) A frequency at which coherent electromagnetic radiation of energy is useful for communications purposes; roughly the range from 10 KHz to 300 GHz. RAM Random access memory. Memory that can be written into, or read, by locating any data address. read rate Ratio of the number of successful reads on the first attempt to the number of attempts. reader An input device that reads bar codes, converting the input data to electronic data. Typically consists of a scanner, a decoder, and a data communications interface. reader command A reader command causes the reader or terminal to perform a task. You can enter a reader command by typing on the keypad, by scanning a bar code label, or by sending a command from a device on the 2.4 GHz network. records/block The maximum number of data records transmitted per block of data. A block of data is transmitted during a single transmission event.

G-22

Page 245

HelvC NugFont

Co d e 39 Glossary

G regular label A bar code label that takes the form of <start code data stop code>. A regular bar code label is executed when you scan it. Contrast with multiple-read label. REQ Request for Acknowledgment character. Sent by the reader to the host to request a retransmission of an acknowledgment to a reader message. RES Reset character. Sent by the reader to end communication with the host. The RES character enables or disables the reset event, or resets the data transmission event to the solicitation event. reset event Terminates the current data transmission event and resets the communication event to the solicitation event. To enable the reset event, define RES to be other than NULL. RF data collection system Radio frequency data collection system in which the individual components communicate with each other by radio signals. RFNC address The radio frequency network controller’s address that is used by the devices to communicate with the BRUs attached to the controller. ROM Read only memory. Usually a small memory that contains often-used instructions, such as microprograms or system software. ROM is programmed during memory fabrication and cannot be reprogrammed. RS-232 Widely recognized protocol standard for serial binary data interchange. The standard covers the physical, electrical, and functional characteristics of the interface. RS-232 is the standard American format for serial data transmission by cable (that is, from a computer terminal to a modem). RS-232 transmission uses a distinctive 25-pin connector, although in most cases not all the conductors are used. See serial.

G-23

Page 246

IRL Programming Reference Manual HelvC NugFont Co d e 39

RS-422 Standard for the voltage and impedance levels for serial data transmission on balanced lines. Similar to RS-232, but handles larger distances and faster communication. RS-485 Standard for allowing multiple devices to share a common set of serial data communication lines. The signaling is very similar to RS-422. The maximum number of devices allowed is 32. RUN Compile and Run IRL Program character. Sent by the host to indicate the end of a downloaded program. Causes the reader to compile the program. If the program compiles correctly, the reader runs the program. RX EOM1 Receive End of Message First character. Enables or disables receiving data and/or indicates the end of a data block in the receive data event. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. RX EOM2 Receive End of Message Second character. Enables or disables the second character of the RX EOM and indicates the end of a data block in the receive data event. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. scan To read a bar code with a device known as a scanner, which converts optical information into electrical signals.The search for a symbol that is to be optically recognized. Movement of a light source over a bar code and recognition of the reflective qualities of the returned signal. scanner devices Typically, a light-emitting device that reads a coded language. This type of device includes wands and laser scanners.

G-24

Page 247

HelvC NugFont

Co d e 39 Glossary

G

Scanner mode Defines how the scanner operates when the trigger is pulled. There are two types of modes: One-Shot or Automatic. One-Shot mode requires you to activate the scanner each time you want to scan a bar code. Once you scan a bar code, the scanner turns off. Automatic mode allows you to activate the scanner once and scan a series of bar codes. When you release the Scan button or trigger on a cabled scanner, the scanner turns off. To scan the same bar code more than once, you must release the button or trigger, or scan a different bar code before attempting a second scan. scanner timeout Maximum time the scanner stays on after you press the Scan button or activate a cabled laser scanner. SEL Select character. Sent by the host to request if the reader can accept data. For User Defined Multi-Drop protocol, a unique character should be defined for each reader on a data line. Select Sequence command A controller command to request if a polled device can receive data. self-checking Characteristic of a bar code symbology that, without the use of a check digit, allows the bar code to be decoded without an error. self-checking bar code Self-checking bar code uses an algorithm that can be applied against each character so substitution errors can only occur if two or more independent printing defects appear within a single character. serial A communications scheme in which the bits of a byte are transferred one at a time. Often serial transmission is used to link host computers to terminals and PCs to printers. server A computer that is configured to provide services to the network. SNA (System Network Architecture) The IBM architecture for supporting computer communications between dissimilar systems.

G-25

Page 248

IRL Programming Reference Manual HelvC NugFont Co d e 39

SOH ASCII control character representing Start of Heading. software Coded instructions that direct the operation of a computer. A set of such instructions for accomplishing a particular task is referred to as a program. Contrast with firmware. solicitation event A communication event that initiates data transmission. The solicitation can be either a poll or select sequence. To enable solicitation, define POL to be other than NULL. SOM Start of Message character. The first character in messages sent to or received from the host. SOP Start of Program Block character. Sent by the host at the beginning of a block of IRL program statements. space The light element of a printed bar code symbol. The white lines. Standard protocol A communications protocol capable of controlling communications between two devices connected by a single data communication line. start/stop code (or character) A special bar code character that provides the scanner with start and stop reading instructions as well as a scanning direction indicator. The start character is normally at the left hand end of a horizontally oriented symbol (bar code label). The stop character is normally at the right hand end of a horizontally oriented symbol. For Code 39, the asterisk (*) character is used. stop bits Used in setting communication protocol. Depends on the host computer configuration. string A sequence of characters.

G-26

Page 249

HelvC NugFont

Co d e 39 Glossary

G

STX ASCII control character representing Start of Text. symbology See bar code symbology. text Human-readable alphanumeric characters, as opposed to machine-readable bar codes. timeout A defined time allowed for an event after which an alternate action is taken. time append A controller or reader feature that stamps the time to incoming messages at specified intervals. The time appears with the messages as they are received at the controller. time broadcast A controller feature that broadcasts the current time (may include a short message) to the data collection devices. The time is updated at specified intervals. timeout A defined time allowed for an event after which an alternative action is taken. An error recovery rule. The amount of time the controller or the polled device will wait between received characters before aborting the transmission or requesting retransmission by a handshake event. If XON/XOFF flow control is enabled, the timeout event must be disabled entirely. To enable flow control, define XON to be other than NULL. timeout delay The time the reader waits between received characters before an I/O (input/output) error occurs. TRAKKER Intermec’s family of 94XX programmable, portable bar code readers. TRAKKER readers use IRL programs. TRAKKER Antares terminals (introduced in 1996) cannot run IRL programs.

G-27

Page 250

IRL Programming Reference Manual HelvC NugFont Co d e 39 transaction A transaction is made up of a header and a group of fields. For example, a work order transaction might have a transaction type and three fields consisting of a work order number, part number, and due date. Trigger mode The conditions that turn the laser on and off. See also Edge Trigger mode and Level Trigger mode. turnaround delay The amount of time a polled device waits after receiving a character before transmitting any response to the controller. Two of Five Code A bar code symbology that is fixed length, discrete, and self-checking. It requires loose printing tolerances. It is used for warehouse sorting systems, photofinishing envelopes, and sequentially numbered airline tickets. The character set is 0 – 9. The maximum density is 7.7 characters per inch. TX EOM1 Transmit End of Message First character. Enables or disables the transmission of the TX EOM characters and/or indicates the end of a data block in the data transmission event. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. TX EOM2 Transmit End of Message Second character. Enables or disables the second character of the TX EOM and indicates the end of a data block in the data transmission event. Older Intermec products may not include these protocol characters. Newer generation online reader products implement these protocol acronyms. UDP User datagram protocol. UDP protocol is an alternative to TCP. This protocol is the Internet standard for wireless devices. You can use UDP when you do not need a guaranteed delivery. You can also use UDP when you do not require all the services of TCP. UDP Plus This Intermec-designed protocol is based on UDP. UDP Plus improves the performance of devices in a mobile wireless environment. Intermec uses this protocol to communicate between the Model 200 Controller and TRAKKER 2425 terminals.

G-28