Page 211 read from a scan by OCR; it may hold reading errors

© 1987 INTERMEC Corporation

Page 7-39

Table 7-8 (cont.) Other Variations of UUM (Unsolicited Receive and Unsolicited Transmit)

CAN BE DELETED COMMENT

FROM HOST: SOM Yes If deleted, 9154 will not check for SOM in messages sent by host.

EOM No Must be nonblank. The EOM must be sent to delimit a message sent to 9154.

EOR Yes Can be deleted if the host does not use record separators in the message sent to 9154.

AFF NA Not used in UUM.

NEG NA Not used in UUM.

DLE Yes Can be deleted if the host message does not contain SOM, EOM, or EOR as data. POL Yes Must be deleted to select UUM protocol.

SEL Yes Must be deleted to select UUM protocol.

Four Types of 9154 Communication

Page 212 read from a scan by OCR; it may hold reading errors

HOST TO 9154 COMMUNICATION

HOST COMPUTER CONTROL OF THE 9154

While some of the controller parameters can be set only from the Supervisory CRT, a number of controller configuration parameters can be configured by the host computer.

The host commands discussed in this section are used in a host application program to allow control and configuration of the controller.

When the host computer modifies controller parameters, only the RAM copy of the configuration parameters is changed. The EEPROM copy of the configuration parameters is left unchanged, unless the specific host EEPROM update command is invoked. This prevents over-writing the EEPROM so many times that its write limit is exceeded. It is assumed that the host computer may be adjusting controller configuration parameters on a daily basis.

The 9154 Multi-Drop Line Controller is designed to be compatible with the INTERMEC 9161 02 Multi-Drop Concentrator. Some of the commands implemented on the 9161 02 Multi-Drop Concentrator are not implemented on the 9154 Controller because the 9154 Controller has only one Multi-Drop port and the 9161 02 has four Multi-Drop ports.

The host computer should be configured so that it automatically inserts the necessary communication protocol required to send commands from the host. See the preceding parts of this section for specific descriptions of the data communication protocol.

Page 7-40 © 1987 INTERMEC Corporation

Page 213 read from a scan by OCR; it may hold reading errors

Host Computer Control of the 9154

Command Summary: The following commands can be sent from the host computer to the controller.

Command: Action:

sD Suspend Polling a Specific Device

SE Start Polling a Specific Device

RG Start Polling

RS Suspend Polling

XMz Start Polling on a Port

XNz Suspend Polling on a Port

TW Display Time on Polled Devices

TN Stop Displaying Time on Polled Devices

TE Record Time Messages as Part of Data Stream TD Stop Recording Time Messages

TS Set the Real Time Clock

TR Set the Real Time Clock (a 9161 02 command) TH Define Time Preamble

TP Define Time Postamble ss Transmit Device Status

Z Supervisory CRT Cursor Position

Vv Supervisory CRT Clear Screen

UE Update Controller EEPROM Parameters

For more information about specific implementation of these commands, see the individual descriptions that follow.

© 1987 INTERMEC Corporation Page 7-41

Page 214 read from a scan by OCR; it may hold reading errors

HOST TO 9154 COMMUNICATION

Start or Stop Polling

$Dz

SD is the disable polling on a specific device command. zis the address(es) of the device to be disabled.

This command also clears all previous errors or any pending message(s) intended for the specific device from the host.

If the z parameter is not specified, the controller will disable polling of all devices.

SEz SE is the enable polling on a specific device command. zis the address(es) of the device to be disabled.

If the z parameter is not specified, the controller will enable polling of all devices.

RG

This message enables device polling. It is the start or resume polling command.

RS

This message suspends polling of all devices. It is the stop/suspend polling command. After this command is transmitted by the host, readers will be unable to scan bar code.

Page 7-42 © 1987 INTERMEC Corporation

Page 215 read from a scan by OCR; it may hold reading errors

Host Computer Control of the 9154

XMz XM is the start polling port command. z specifies the ports to be enabled.

This message enables the polling of devices on a specific port and clears all previous efrors or pending messages from host to polled devices:

On the controller, z can specify port m,n, 0, orp. If a port is specified, that port must be the same port address that the controller is using for its Multi-Drop port. If no port address is specified, the controller will enable its single Multi-Drop port and the port address will remain the same value defined using the Supervisory CRT. XMz is a 9161 02 Multi-Drop iConcentrator command implemented on the controller.

XNz XN is the stop polling command.

z specifies the ports to be disabled.

This message disables the polling of devices on a specific port. After this command is transmitted by the host, readers will be unable to scan bar code.

If the z parameter is not specified, the controller will disable its single Multi-Drop port. If the port to disable is specified, the controller requires that the specified port match the port address assigned to its single Multi-Drop port (m,n,o,p). XNz is a 9161 02 Multi-Drop Concentrator command implemented on the controller.

© 1987 INTERMEC Corporation Page 7-43

Page 216 read from a scan by OCR; it may hold reading errors

HOST TO 9154 COMMUNICATION

Enable/Disable Time Broadcast TT

This message instructs the controller to enable Time Broadcast so thata time message which will be displayed. It is the time message broadcast command. When the preamble is the factory default value (HT), the message will be right-justified on the device status display.

The time message is composed of either hour and minutes, or year, month, day, hour, and minutes, depending on how the controller is configured.

The broadcast interval is a configurable parameter. The date format and time interval of broadcast are determined by parameters whose values are set on the Supervisory CRT screens. The default values are every one minute for time interval, and a 24-hour clock for time format. The time messages may have a preamble and/or postamble, and the default is "HT" for preamble and no postamble. The preamble and postamble are entered from the Supervisory CRT screens or using the TH and TP commands.

TN This message instructs the controller to disable time broadcast messages to the devices for display on their status display. It is the stop time message broadcast command.

Page 7-44 © 1987 INTERMEC Corporation

Page 217 read from a scan by OCR; it may hold reading errors

Host Computer Control of the 9154

Enable/Disable Time Append

TE

This message instructs the controller to record time messages along with the data, using time messages generated by the controller real time clock. Itis the enable time append command.

The default time value is 87:01:01:00:00, that is, January 1, 1987, 00 hours, 00 minutes. The default time interval for changing the time is one minute. Every minute a new time message will be recorded. To set the real time clock to a new time, use either the Supervisory CRT or the set real time clock command below.

TD

This message instructs the controller to stop recording time messages along with the data. It is the Disable Time Append.

© 1987 INTERMEC Corporation Page 7-45

Page 218 read from a scan by OCR; it may hold reading errors

HOST TO 9154 COMMUNICATION

Set Real Time Clock: To set the real time clock parameters to something other than the default values, send one of the following messages. This is a command that might be used every day to set the controller real time clock.

TS DDhhmmaabb

TS is the time set command.

DD is the day field (1-31).

hh is the hour field (00-23).

mm is the minute field (00-59).

aa is the time message recording interval in minutes (00-99).

bb is the time broadcast interval in minutes (00-99).

The default hours format is military time (0-23 hours). Parameters aa and bb may be left out if desired. If the time format is in error, the time will not be updated, but if parameters aa or bb are entered, they will be processed.

TS is a 9161 02 Multi-Drop Concentrator command implemented on the controller. The date fields not included in this command, year and month, will remain unchanged. These unchanged date fields must be configured using the Supervisory CRT Select Clock Parameters screen or the TR command.

Page 7-46 © 1987 INTERMEC Corporation

Page 219 read from a scan by OCR; it may hold reading errors

Host Computer Control of the 9154

TR YYMMDDhhmmaabbccde

TR is the time set command (not compatible with the 9161 02). YY is the year field (0-99).

MM is the month field (1-12).

DD is the day field (1-31).

hh is the hour field (00-23).

mm is the minute field (00-59).

aa is the time append interval in minutes (00-99).

bb is the time broadcast interval in minutes (00-99).

cc is the time broadcast mode (12 or 24 hour clock).

dis enable/disable Day Rollover (Y = yes, N = no).

e is enable/disable Include YY/MM/DD (Y = yes, N = no).

The default hours format is military time (0-23 hours). Parameters aa and e may be left out if desired. if the time format is in error, the time will not be updated, but if parameters aa or e are entered, they will be processed.

Other time features can also be modified with the commands that follow.

TH xxxxx TH is the define time broadcast preamble command.

xxxxx is the preambie. Only the first five characters are accepted. If the field is left blank, the preamble will be disabled.

TH is not implemented on the 9161 02 Multi-Drop Concentrator.

© 1987 INTERMEC Corporation Page 7-47

Page 220 read from a scan by OCR; it may hold reading errors

HOST TO 9154 COMMUNICATION

TP xxxxx TP is the define time broadcast postamble command.

xxxxx is the postamble. Only the first five characters are accepted. If the field is left blank, the postamble is disabled.

TP is not implemented on the 9161 02 Multi-Drop Concentrator.

Device Status Command

SS Xz

SS is the device status command.

X is the port address (m,n,0,p).

z is the Multi-Drop address (A-Z, 0-5).

Together, X and z specify which device is to be polled. X must match the value assigned the controller port.

The status of several devices may be requested in the same imessage. Each address should be separated from the preceding address by the End of Record character.

Page 7-48 © 1987 INTERMEC Corporation