Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 33

9154 Line Controller System Manual, pages 1 to 10

Pages 1 to 10 of 330

The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9154

Page 1 read from a scan by OCR; it may hold reading errors

9154 Line Controller

System Manual

A CrossBar Network Product

INTERMEC® Corporation 6001 36th Avenue West P.O. Box 4280

Everett, WA 98203-9280

The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service INTERMEC manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of INTERMEC.

The word INTERMEC, the INTERMEC logo, the "bar" logo, IRL, DURATHERM and CrossBar are trademarks. of INTERMEC Corp. ,

Information and specifications in this manual are subject to change without. | notice.

INTERMEC Part No. 048517 Version C_

© 1987 INTERMEC Corporation lit) INTERMEC°

Solutions for Data Collection

Page 2 read from a scan by OCR; it may hold reading errors

Throughout this manual, trademarked names may be used. Rather than put a trademark (™) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Federal Communications Commission Radio Frequency Interference Statement

Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

Note: In order to meet Class A emission limits, the I/O cables that interconnect between the device and any peripheral (such as a printer, external modem, etc.) must be shielded.

Page 3 read from a scan by OCR; it may hold reading errors

WARRANTY INFORMATION

INTERMEC Corporation offers its customers a choice of warranty options. To receive a copy of the standard warranty provision for this product, contact your local INTERMEC sales organization and request the information. Refer to the Authorized Service Locations list which was shipped with this manual for the address and telephone number.

Upon request, customers who are residents of the USA and Puerto Rico will receive the INTERMEC Corporation Supplemental Statement of Warranty (Form 603876); customers residing outside the USA will receive a Statement of Warranty prepared and supported by their local INTERMEC distributor.

doued imoduhed vies bes ‘de@wing ai deum (slo mehom lavere. coinhe + sis noblaita

©1987 INTERMEC Corporation

Page 4

This page is a scan with no text; see it in the PDF.

Page 5 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

SECTION 1 HOW TO USE THIS MANUAL

INTRODUCTION TO THE 9154 MULTI-DROP LINE CONTROLLER

SYSTEM MANUAL 1-2 MANUAL AUDIENCE 1-2 USING THIS MANUAL EFFECTIVELY 1-3 RELATED INTERMEC MANUALS 1-5 WARRANTY INFORMATION 1-5 SAFETY SUMMARY 1-6 General Safety Guidelines 1-6 Warning and Cautions 1-7 DOCUMENTATION CONVENTIONS 1-13 Terminology 1-13 Keystroke Definitions 1-13

SECTION 2 INTRODUCTION TO THE 9154

INTRODUCTION 2-2 LOCATING CONTROLLER COMPONENTS 2-4 Front Panel 2-4 Rear Panel 2-5 Status and Power Lights 2-7

© 1987 INTERMEC Corporation l

Page 6 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

CONTROLLER FEATURES 2-8 Controller Internal Features 2-8 Controller External Features 2-8 Controller Supervisory CRT Interface Features 2-9 Controller Host Interface Features 2-10 Controller Polled Device Interface Features 2-11

A SAMPLE 9154 SYSTEM 2-12

SECTION 3 DESIGNING A 9154 SYSTEM

DESIGN CONSIDERATIONS 3-2 PLANNING THE PHYSICAL LAYOUT 3-2 installation Plan 3-2 Installation Guidelines 3-4 Laying Multi-Drop Cabling 3-8 Test System 3-8 SELECTING A COMMUNICATION INTERFACE BETWEEN THE HOST AND 9154 3-10 Available Interfaces 3-10 Comparing RS-232 and RS-422/485 3-12 Data Line Considerations 3-14 GROUNDING CONSIDERATIONS 3-14 Communication Interfaces and Grounding 3-15 Grounding Conductor 3-15 Making a Good Ground Connection 3-16 Grounding Long Data Lines ~ 3-17 LIGHTNING PROTECTION 3-17 THROUGHPUT AND RESPONSE TIME ANALYSIS 3-17 Introduction an 3-17 Calculating the Response Time” 3-18

Deriving Cycle Times 3-21 il © 1987 INTERMEC Corporation

Page 7 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

CONFIGURATION PREPARATION 3-26 Data Communication Considerations 3-26 Configuration Parameters 3-27

SECTION 4 INSTALLING HARDWARE

INSTALLATION OVERVIEW 4-2 INSTALLING THE 9154 CONTROLLER 4-3 Unpacking 4-3 Standard Items 4-4 Required Tools 4-4 Mounting 4-5 Connecting the Controller to Ground 4-8

Power Sources 4-9 CONNECTING THE SUPERVISORY CRT TO THE 9154 4-13 Configuration 4-13 Controller to CRT Interface 4-13 Connecting the Controller to the CRT 4-14 CONNECTING THE HOST COMPUTER TO THE 9154 4-16 Choosing an Appropriate Interface 4-16 RS-232 4-17 RS-422/485 4-21

Modem 4-22 Current Loop . 4-23 CONNECTING THE 9154 TO POLLED DEVICES 4-23 Compatible Readers and Printers 4-25 Designing a Multi-Drop Cable Layout 4-26 Multi-Drop Cables 4-27 installing a Multi-Drop Cabling System 4-31

| Segment-By-Segment Main Trunk Cable Installation 4-31 Laying the Main Trunk First 4-34 Connection to Specific Readers 4-35 VERIFYING SYSTEM INSTALLATION 4-36

© 1987 INTERMEC Corporation Hl

Page 8 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

SECTION 5 CONFIGURING THE CONTROLLER CONFIGURATION OVERVIEW APPLYING POWER TO THE 9154

CONFIGURING THE 9154 TO COMMUNICATE WITH THE SUPERVISORY CRT Automatic Baud Rate Detection Sequence Selecting Supervisory CRT Terminal Type Configuring for a Non-Standard CRT

MASTER MENU

INITIALIZING THE CONTROLLER Using the Supervisory CRT Screens to Configure Saving Parameters Screen Commands

SELECT OPERATING PARAMETERS Line Parameters for Host Port Multi-Drop Parameters Saving Operating Parameters

SELECT TRANSMISSION PARAMETERS How to Select Transmission Parameters To Host Transmission Parameters From Host Transmission Parameters Saving Transmission Parameters

SELECT CLOCK PARAMETERS Set Real Time Clock Time Append Parameters Time Broadcast Saving Clock Parameters

5-3 5-4 5-4 5-6

5-9

5-9 5-10 5-11 5-13

5-15 5-16 5-18 5-19

5-20 5-21 5-24 5-28 5-32

5-33 5-34 5-35 5-37 5-40

Iv © 1987 INTERMEC Corporation

Page 9 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

SELECT POLLED DEVICES 5-41

Enabling Device Addresses 5-42 VERIFYING CONTROLLER CONFIGURATION 5-44 SETTING DEVICE ADDRESSES 5-46

SECTION 6 CONFIGURING POLLED DEVICES

INTRODUCTION 6-2 MULTI-DROP POLLING ON THE 9154 6-3 MULTI-DROP PROTOCOL 6-5 Selecting Multi-Drop Protocol 6-5 Setting Baud Rate 6-7 Setting the Device Address 6-7 USER-DEFINED MULTI-DROP PROTOCOL 6-7 Configuring a Device’s Communication Parameters 6-8 Setting Baud Rate 6-9 Setting the Device Address 6-9 TRACKING ADDRESS USAGE 6-11 DETERMINING AVAILABLE DEVICE ADDRESSES 6-13

SECTION 7 HOST TO 9154 COMMUNICATION

INTRODUCTION 7-2

© 1987 INTERMEC Corporation Vv

Page 10 read from a scan by OCR; it may hold reading errors

TABLE OF CONTENTS

DATA COMMUNICATION BETWEEN THE HOST AND 9154 7-2 Data Format 7-3 9154 to Host Communication Protocol 7-4 Host to 9154 Communication Protocol 7-6 XON/XOFF Handshake 7-9 Transparency Character 7-12 Longitudinal Redundancy Check 7-13

FOUR TYPES OF 9154 TO HOST COMMUNICATION 7-15 Solicited Receive and Solicited Transmit (SSM) 7-18 Solicited Receive and Unsolicited Transmit (SUM) 7-24 © Unsolicited Receive and Solicited Transmit (USM) 7-30 Unsolicited Receive and Unsolicited Transmit (UUM) 7-36

HOST COMPUTER CONTROL OF THE 9154 7-40 Start or Stop Polling 7-42 Enable/Disable Time Broadcast 7-44 Enable/Disable Time Append 7-45 Device Status Command 7-48 Tailoring the Controller for a Supervisory CRT Screen 7-49 Updating the Controller EEPROM 7-51 9161 02 Multi-Drop Concentrator Host Commands Not Implemented on the 9154 Controller 7-51

SECTION 8 CRT CONTROL OF 9154 COMMUNICATION

INTRODUCTION 8-2 SUPERVISORY CRT COMMAND SUMMARY 8-4 FLUSHING THE DATA QUEUES 8-7 CONFIGURATION PARAMETERS 8-8 RAM 8-8 EEPROM 8-9 Factory Default Settings 8-9 vi © 1987 INTERMEC Corporation