Page 68

Section 6

Troubleshooting "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Sometimes, a careful check will reveal that what you thought was a malfunction actually was not. Before requesting repairs, carefully consult this section and try to resolve the problem.

PEN*KEY R 6642 Pen Computer User’s Guide 6-1

Page 69

Troubleshooting

SECTION 6

Problems on Start–up Why doesn't the power switch function? Confirm that the power cord is connected properly. " Connect another electrical device to the power outlet in order to confirm that power is live from the outlet. " Check that the batteries are not fully discharged; conĆ nect the pen computer to an electrical outlet. Why doesn't Windows start? "

Check to see if the external floppy disk drive/port exĆ pander contains a non-system disk. Remove the floppy disk from the drive and press any key. " If booting from an external floppy disk drive, check to make sure the floppy disk is fully inserted into the drive. " Check to make sure the floppy is setup as the first boot device in the setup menu. " Confirm that the system files have not been deleted from the hard disk. " Depending on the state that the pen computer is in, the power button might not function. In that case, use the RESET switch on the bottom of the pen computer to turn off the power. Why do I get a non-system disk or disk error message? "

"

"

"

6-2

There may be a non-bootable disk in the external floppy disk drive/port expander (either a defective disk or one without an operating system). Remove the disk. If the message appears when you try to boot from the hard drive, insert a bootable disk into the external floppy disk drive/port expander and check the status of your hard disk drive. Check whether the items Diskette A: or Hard Disk Type: are set up correctly in the Main section of the setup utility.

PEN*KEY R 6642 Pen Computer User’s Guide

Page 70

SECTION 6

Troubleshooting

Why do I get the message Operating System not found? "

"

Insert a boot up disk into the external floppy disk drive/port expander, then check the condition of the hard disk. Check the hard disk status from the setup utility. Check the size of the hard disk and make sure the Hard Disk Drive Type in the Main menu is set to Auto.

Problems with Display Why is the screen blank? "

"

"

"

"

Press any key to see if power management has turned off the screen to save power. Check the power LED to see if the pen computer has power. If you are using the internal battery pack, make sure it has charge remaining. If you are using the expanĆ sion battery pack, make sure it is connected correctly and has charge remaining. Press the power switch, wait 10 seconds and try turning the power back on. If you cannot restart the pen computer using the above procedure, press the reset button with the stylus pen, loĆ cated on the bottom of the 6642 and turn off the system. Wait 10 seconds and turn the pen computer back on.

Why is there no display on the external monitor? " " "

Confirm that the monitor is powered on. Confirm that the monitor is connected correctly. Check that the display setting is not set for external CRT monitor.

PEN*KEY R 6642 Pen Computer User’s Guide 6-3

Page 71

Troubleshooting

SECTION 6

Why is the image on the external monitor display distorted? " "

" "

Check that the monitor is connected correctly. Make sure the CRT is not near any electric devices that have a stong magnetic fields such as a TV set, fan or radio. Do not share an outlet with a TV set or radio. Make sure the value of the Screen area in the Display Properties in Control Panel is equal to or lower than the resolution of the CRT monitor.

Problems with Hard Disk Why can't I read or write data to or from the hard disk? " Confirm the drive and file names are correct. " Confirm the hard drive has enough free space. " The hard disk in your computer is formatted with FAT32. You cannot read or write data formatted in other operating systems which are not FAT32 compatĆ ible. Applications not FAT32 compliant may not work properly.

Problems with Floppy Disk Why can't I use a floppy disk? "

" " "

"

"

6-4

Confirm that the external floppy disk drive/port expander is correctly connected. Check that the floppy disk is inserted correctly. The floppy disk may be unformatted or corrupt. If you cannot write to a floppy disk, the disk may be write-protected. Eject the disk and check that the write-protect tab covers the detection hole. If you cannot write to a floppy disk, the disk may be full. Use another disk. Check that the floppy disk drive setting is set to 1.44MB in the setup utility.

PEN*KEY R 6642 Pen Computer User’s Guide

Page 72

SECTION 6

Troubleshooting

Problems with Touch Panel Why is the touch panel not functioning correctly? "

"

Confirm that the touch panel is correctly calibrated with the pen software. Run the calibration application from the program menu. Check to make sure the touch panel on the 6642 is clean and free of dirt. Check the pen stylus for dirt or foreign matter.

Problems with Peripherals Why don't expansion or peripheral devices function? Confirm that they are correctly connected to your pen computer or the external floppy disk drive/port exĆ pander. " Confirm that the external floppy disk drive/port expander is connected correctly to the computer if peripheral devices are connected to the external floppy disk drive/port expander. " Confirm that drivers necessary for operating ports on the devices are installed. " There may not be a free IRQ (interrupt). Free up an IRQ from a built-in device. Why can't I print? "

" "

" " "

"

Make sure the printer is turned on and on-line. Check to see if the external floppy disk drive/port expander and the printer are connected correctly. Check to see if the printer has enough paper. Check to see if the printer driver is installed. Make sure the LPT port setting in the setup utility is set correctly. From the Start menu in Windows, select Settings Printers to confirm your printer is installed. If not, tap Add Printer to install your printer. PEN*KEY R 6642 Pen Computer User’s Guide 6-5

Page 73

Troubleshooting

SECTION 6

Why doesn't the device connected to the RS-232C serial port function? "

Confirm that the device is correctly connected to the floppy disk drive/port expander with an appropriate cable.

Confirm that the external floppy disk drive/port exĆ pander is connected correctly. " Confirm that the application program is compliant with the RS-232C standard interface. " Confirm that the COM1 port is not disabled by doing the following: 1. In the System Properties dialog box, select Device Manager. 2. Double-tap Ports, (COM&LPT); then double-tap ComĆ munications Port (COM1). 3. Make sure the item Disable in this hardware profile is unchecked. " Confirm that COM1 is not used by another application. " Confirm that the Serial Port is set up correctly in the setup utility. "

6-6

PEN*KEY R 6642 Pen Computer User’s Guide

Page 74

SECTION 6

Troubleshooting

Problems with Communications Why can't I communicate through the built-in IR port? "

"

"

"

Confirm that the IR port of the 6642 is lined up with the IR port of the other device. These ports should be no more than 20 inches (50cm) apart without any obĆ stacles. Confirm that the IR communication is not turned off in the IR dialog box. Confirm that the item Mode of IR Port is set to IrDA in the setup utility. Turn off power management both in Windows and in the setup utility.

Do not use the IR port under intense fluorescent light or near cellular phones. Why can't I communicate through the built-in modem? "

(The built-in modem is not available in all countries) "

"

"

"

" "

Confirm that the item Modem is enabled in the setup utility. Confirm the telephone line is properly connected to the modem jack. Confirm the dial setting of the communication softĆ ware are matched with the telephone line (Example: To access an outside line, first dial for local for long distance). Confirm that the network configuration is appropriĆ ate. Confirm the user name or password is correct. Confirm that the COM port in the communication softĆ ware is set appropriately.

PEN*KEY R 6642 Pen Computer User’s Guide 6-7

Page 75

Troubleshooting

SECTION 6

Other Problems Why is the date or time incorrect? "

"

" "

Correct the date and time using the Date/Time icon in the Windows Control Panel or the Main menu of the setup utility. Connect the AC adapter for at least eight hours in orĆ der to charge the backup battery. Use the Setup utility to set the correct date and time. If the correct date and time are still not displayed, conĆ tact an Intermec service center and have the backup battery on the system board replaced.

Why is there no sound output? "

Check the speaker icon fromthe taskbar icon and check the Windows volume control.

Why can't I use a hardware device? "

Make sure the device is not disabled from Windows by check ing the Device Manager tab in System Properties. Check to see that the Disable in this hardware profile box is unchecked.

Why don't PC Cards work in MS-DOS mode? "

Confirm that there are no conflicts involving COM3, which is used by cards, and COM1, which is used by other devices. This is because COM1 is already used by other pen computer devices. Use the setup utility to change the COM port settings. When a PC card uses COM3, set the Port" item to

Why don't PC Cards Function? "

6-8

Confirm that the PC Card is inserted right side up in the PC Card slot. Check that the card is inserted fully into the slot. If you are using a PC Card modem, check the modem cable connections.

PEN*KEY R 6642 Pen Computer User’s Guide

Page 76

SECTION 6

Troubleshooting

Factory Service If the unit is faulty, you can phone your designated InterĆ mec Service Center for repair advice, instructions, or to obĆ tain factory-quality repair service. Their telephone number and address can be found on the warranty card. Many failures may be repairable on-site, which is why it is important that you telephone first. When products must be shipped for repair: "

"

"

Package the unit in the original shipping carton, if possible. Fill out a Product Service Information Card (a part of the warranty card). Send this card with the product. For warranty or technical assistance, telephone 1-800-755-5505.

Customer Response Center The Customer Response Center (technical support) teleĆ phone number is 1-800-755-5055 (U.S.A or Canada) or 1-425-356-1799. The facsimile number is 1-425-356-1688. Email is support@intermec.com. If you email or fax a problem or question, include the following information in your message: " " " "

Your name Your company name and address Phone number and email address to respond to Problem description or question.

If the equipment was purchased through a Value-Added Reseller (VAR) include that information.

PEN*KEY R 6642 Pen Computer User’s Guide 6-9

Page 77

Troubleshooting

SECTION 6

Web Site The Customer Support File Libraries, including Hot Tips and Product Awareness Bulletins, are available on the Internet. New users start at the Intermec web site: www.intermec.com. Choose then Support," then Area." Look on the main page for a link to register new cusĆ tomers. A PDF version of this manual will be available at this address: www.intermec.com/manuals/english.htm or choose then and from the opening page.

Bulletin Board Service The Customer Support Bulletin Board (BBS), maintained by the Norand Mobile Systems Division of Intermec Technologies Corporation, provides software and documentation. "

"

6-10

Phone Number: 319-369-3515 (14.4Kbps modem) 319-369-3516 (28.8Kbps modem) Protocol: Full duplex, ANSI or ANSI-BBS; 300 to 28,800 bps;v.32bis; 8 bits, no parity, 1 stop bit. For high-speed modems, disable XON/XOFF and enable RTS/CTS.