The text of a manual · part 30 of 33
VT220/ANSI Terminal Emulation Programmer's Reference Guide: Section 9: Extended Commands, pages 243 to 251
Pages 243 to 251 of 276, from VT220/ANSI Terminal Emulation Programmer's Reference Guide
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 243
SECTION 9
"
Extended Commands
Plessey If the Plessey bar code scanning algorithm is enabled, set its check digits (Table 9-15) according to your requirements. See the manufacturer’s bar code specifications for more information on check digits. Table 9-15 Plessey Characters Line 1, Column 14 Character Description 0 1 (Space)
Plessey disabled. Plessey enabled. No change from current setting.
The dots in Table 9-17 on the next page indicate the Plessey check digits the characters support. (The PEN*KEY 6400 Computer’s internal engine does not support Plessey alpha characters.)
Codabar The Codabar options (Codabar and ABC Codabar, Table 9-16) are mutually exclusive coding algorithms and cannot be selected at the same time. (The PEN*KEY 6400 Computer’s internal engine does not support ABC Codabar.) Table 9-16 Codabar Characters Line 1, Column 16 Character Description 0 1 2 (Space)
Codabar disabled. Codabar enabled. ABC Codabar enabled. No change from current setting.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
9-37
Page 244
SECTION 9 "
Extended Commands
Table 9-17 Plessey Check Digit Characters Line 1, Column 15 Plessey Check Digit
Character
Keep 2nd Digit Check
Do Not Validate 1st Check Digit
Keep 1st Check Digit
Mod 10 1st Check Digit
0
Mod 11 1st Check Digit
·
1
·
2
·
3
·
4
·
5
·
6
·
·
7
·
·
8
· · · · · ·
·
9
·
A
·
·
B
·
·
C
·
·
D
·
·
E
·
·
·
F
·
·
·
(Space)
· · · · · · · ·
No change from current setting.
Code 11 Table 9-18 lists Code 11 characters. (The PEN*KEY 6400 Computer’s internal engine does not support Code 11.)
9-38
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
Page 245
SECTION 9
"
Extended Commands
Table 9-18 Code 11 Characters Line 1, Column 17 Character Description 0 1 (Space)
Code 11 disabled. Code 11 enabled. No change from current setting.
Code 93 Both Code 93 and Code 128 options can be enabled for scanning. (The PEN*KEY 6400 Computer’s internal engine does not support Code 93.) Table 9-19 Code 93 Characters Line 1, Column 18 Character Description 0 1 (Space)
Code 93 disabled. Code 93 enabled. No change from current setting.
Code 128 Table 9-20 lists Code 128 characters. Table 9-20 Code 128 Characters
Line 1, Column 19 Character Description 0 1 (Space)
Code 128 disabled. Code 128 enabled. No change from current setting.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
9-39
Page 246
SECTION 9 "
Extended Commands
Straight or Computer Identics 2of5 If the Straight or Computer Identics bar code is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements (Table 9-21). (The PEN*KEY 6400 Computer’s internal engine does not support Straight or Computer Identics 2of5.) Table 9-21 2of5 Characters Line 1, Columns 20- 28 Column Characters Description 20 0 Straight and Computer Identics 2of5 disabled. Computer Identics 2of5 enabled. 1 Straight 2of5 enabled. 2 No change from current setting. (Space) 21--22
XX
(Spaces) 23--24
XX
(Spaces) 25--26
XX
(Spaces) 27--28
XX
(Spaces) 9-40
Maximum length Straight or Computer Identics 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting. Minimum length Straight or Computer Identics 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting. 1st fixed bar code length for Straight or Computer Identics 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting. 2nd fixed bar code length for Straight or Computer Identics 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
Page 247
SECTION 9
"
Extended Commands
Interleaved 2of5 If Interleaved 2of5 is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements (Table 9-22). Table 9-22 Interleaved 2of5 Characters Line 1, Columns 29- 37 Column CharacDescription ter 0 Interleaved 2of5 disabled. 29 1 Interleaved 2of5 enabled. (Space) No change from current setting. 30--31
XX (Spaces)
32--33
XX (Spaces)
34--35
XX (Spaces)
36--37
XX
(Spaces)
Maximum length Interleaved 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting. Minimum length Interleaved 2of5. See the manufacturer’s bar code specifications for further information. No change from current setting. 1st fixed length for Interleaved 2of5 Bar Code. See the manufacturer’s bar code specifications for further information. No change from current setting. 2nd fixed length for Interleaved 2of5 Bar Code. See the manufacturer’s bar code specifications for further information. No change from current setting.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
9-41
Page 248
SECTION 9 "
Extended Commands
Return Codes for Scan Bar Code Parameters The Scan Bar Code Parameters return code is the status sent to the host computer; the code indicates if the extended command was successful. The wireless station returns data and the extended command’s status to the host computer in the following format: \\X<CR> where “X” is the return code listed in the following chart. The wireless station simulates the [Enter] key to return a value to the host computer. If a hexadecimal number is entered wrong, the return code defaults to “0.” Code
Description
0
Good status, transaction complete.
1
Bad status, transaction incomplete.
Examples of Scan Bar Code Parameters Scan Bar Code Parameters extended command characters can be started by an APC sequence or by a space.
APC Sequence When the control character sequence for APC starts data, all of the data is on Line 1. The control character sequence is not displayed, which results in a faster transmission rate. Also, the cursor position is not lost.
9-42
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
Page 249
SECTION 9
"
Extended Commands
The following example shows data started by the control character sequence for APC. Sequences are prefixed by the notation “ ^ ” which represents “control.” Column 11
Column 2
Column 23
Column 36
^9F#S07F32012211120012080108080bbbbbbbb
Space The following example shows a space as the start of the data. A “b” indicates a space. Column 1
Column 11
Column 23
Column 36 b#S07F32012211120012080108080bbbbbbbb
The following example shows data for Scan Bar Code Parameters. A space starts the data.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
9-43
Page 250
SECTION 9 "
9-44
Extended Commands
Column 1 2 3 4
Character (Space) # S 0
5
7
6
F
7--8 9--10 11 12 13 14 15 16 17 18 19 20 21--22 23--24 25--26 27--28 29 30--31 32--33 34--35 36--37
32 01 2 2 1 1 1 2 0 0 1 2 08 01 08 08 0 (Spaces) (Spaces) (Spaces) (Spaces)
Description This column typically contains a space. Extended command. Scan Bar Code Parameter command. No Control Byte 1 options are returned. [ENTER] key terminates all scans, 12-volt laser is enabled, Modulo 10 Check Digit. Barcode type is returned and concatenated. Maximum length is 32 characters. Minimum length is 1 character. Decode UPC System 0. EAN is enabled. Encoded code 39 is enabled. Plessey is enabled. Mod 10 first digit is checked. ABC Codabar is enabled. Code 11 is disabled. Code 93 is disabled. Code 128 is enabled. Straight 2of5 is enabled. Straight 2of5 maximum length is 8. Straight 2of5 minimum length is 1. Straight 2of5 1st fixed length is 8. Straight 2of5 2nd fixed length is 8. Interleaved 2of5 is disabled. No change from current setting. No change from current setting. No change from current setting. No change from current setting.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
Page 251
SECTION 9
"
Extended Commands
Encoded Code 39 Encoded Code 39 combines key presses with normal bar code data. All regular Code 39 bar codes can be scanned when using Encoded Code 39. “Encoded” refers to special character sequences contained within a standard Code 39 bar code that the wireless station scanning program converts into key presses. This feature allows bar codes to contain commonly-used key press sequences that accompany scanning. An example is a bar code with a forward tab character encoded at the end of it. When the wireless station operator scans the bar code, the wireless station fills in bar code data and automatically performs a forward tab. This moves the cursor to the next field. The operator does not need to press a key between scans. Table 9-23 lists escape characters and key press sequences for Encoded Code 39. The “(t)” in the table indicates a terminating key. Any bar code data following this key code is ignored. The “t” sequences, therefore, should be located only at the end of the bar code. If you attempt to use an invalid sequence (termed “invalid” in the table) the wireless station will beep and the data stream will be flushed.
VT220/ANSI Terminal Emulation Programmer’s Reference Guide
9-45