Page 197

SECTION 8

"

Programming

Local Edit Mode If your application software program supports local editing, the wireless station can be programmed to operate in local edit mode. Local edit mode is a feature of the VT330/VT340 terminal. Use the mode to send characters to page memory instead of to the host. The wireless station sends a block of edited text to the host after you press a terminating key. Wireless station terminating keys in local edit mode are: [ENTER] [F1] through [F20]

Edit Mode and Interactive Mode The edit mode control function (DECEDM) selects edit mode or interactive mode. The function determines when the wireless station sends data to the host. Table 8-41 describes the modes. Table 8-41 Local Edit Modes Mode

Sequence* Wireless Station Action

Set

CSI ? 1 0 h

Selects edit mode. (Turns on the annunciator in the display.) The wireless station stores all typed characters in page memory for local editing. After the data is edited, it can be sent in a block to the host.

Reset

CSI ? 1 0 l

Selects interactive mode. (Turns off the annunciator in the display.) The wireless station immediately sends typed characters to the host.

* The last character in the reset mode sequence is lowercase L (6C hexadecimal).

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

8-61

Page 198

SECTION 8

"

Programming

Local Editing Setup To use the wireless station in local edit mode, the local editing features must be set up for the application software as described in Table 8-42. Table 8-42 Local Editing Setup Feature

Setting

Description

Edit mode

Edit

Edited text is stored in memory until you press a terminating key, which sends the text to the host. Not supported.

Transmit execution mode

Immediate

Local editing application keys

Suffix transmit

The wireless station sends data to the host immediately after you press a terminating key. When you press [F1] through [F20], the wireless station sends that function to the host after sending a block of data.

Line transmit mode

Disabled

Transfer termination mode

Enabled

Edit key execution mode

VT131 transfer mode Space compression

End of line characters

End of block characters

8-62

The wireless station sends a full page of data to the host after you press a terminating key. After you press a terminating key, the wireless station sends the scrolling region, which is the area inside the scrolling margins. Not supported.

Disabled

The wireless station sends a space character for each unused character position. On the wireless station, no characters indicate the end of a line in a data block. On the wireless station, no characters indicate the end of a data block.

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

Page 199

SECTION 8

"

Programming

Selecting Characters to Send Three control functions allow you to define which characters the wireless station can send to the host. Table 8-43 shows how the control functions select which characters the wireless station sends. Table 8-43 Selecting Character Fields for Transmission Fields Selected All fields

Guarded Area Selected Area Multiple Area Transfer Mode Transfer Mode Transfer Mode Set Set Unavailable

Unprotected fields only

Reset

Set

Unavailable

Selected fields only

Set

Reset

Set

Selected field with cursor only

Set

Reset

Reset

Unprotected and selected fields

Reset

Reset

Set

Selected field with cursor only

Reset

Reset

Reset

Guarded Area Transfer Mode (GATM) The guarded area transfer mode control function selects whether the wireless station sends all characters or only unprotected characters to the host. When GATM is unprotected (reset), the wireless station sends a record separator (RS, 1E hexadecimal) to the host in place of a protected field. Table 8-44 lists guarded area transfer modes.

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

8-63

Page 200

SECTION 8

"

Programming

Table 8-44 Guarded Area Transfer Modes Mode

Sequence* Wireless Station Action

Set (All)

CSI 1 h

Selects all characters. During block transmission, the wireless station can send all protected and unprotected characters to the host.

Reset (Unprotected)

CSI 1 l

Selects unprotected characters. During a block transmission, the wireless station can send only unprotected characters to the host.

* The last character of the reset mode sequence is lowercase L (6C hexadecimal).

Selected Area Transfer Mode (SATM) The selected area transfer mode control function determines whether the wireless station can send all characters or only selected characters to the host. Selected characters are characters defined as eligible to send to the host. Table 8-45 lists selected area transfer modes. Table 8-45 Selected Area Transfer Modes Mode

Sequence* Wireless Station Action

Set (All)

CSI 1 7 h

Selects all characters. The wireless station can send selected and unselected characters on the current page to the host.

Reset (Unprotected)

CSI 1 7 l

Selects only selected characters. The wireless station can only send selected characters on the current page to the host.

* The last character of the reset mode sequence is lowercase L (6C hexadecimal).

8-64

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

Page 201

SECTION 8

"

Programming

Multiple Area Transfer Mode (MATM) The multiple area transfer mode control function determines what selected character areas the wireless station can send to the host. MATM work only when SATM is reset. Table 8-46 describes multiple area transfer modes. Table 8-46 Multiple Area Transfer Modes Mode

Sequence* Wireless Station Action

Set (All)

CSI 1 5 h

The wireless station can send all selected areas on the page to the host.

Reset (Unprotected)

CSI 1 5 l

Selects one area. The wireless station can send only the selected area with the cursor. If the cursor is not in a selected field, the cursor moves to the next selected field.

* The last character of the reset mode sequence is lowercase L (6C hexadecimal).

Defining Selected Areas Start selected area (SSA) and end selected area (ESA) control functions select which characters on the current page the wireless station can send to the host. SSA and ESA are 8-bit C-1 control characters that can also be coded as 7-bit escape sequences. The following conditions apply to SSA and ESA: " "

They work only when SATM is reset. If the wireless station receives ESA before SSA, it ignores ESA.

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

8-65

Page 202

SECTION 8

"

Programming

If SSA is not followed by ESA on the same page, the SSA has no effect on that page. Selected areas must always end with ESA. " Selected areas cannot be changed by the ED, EL, or ECH control functions. Table 8-47 describes SSA and ESA. "

Table 8-47 Start Selected Area and End Selected Area Name (Mnemonic) 8-Bit Start selected area SSA (SSA) (86 hex.)

7-Bit Equivalent ESC F (1B, 46 hex.)

End selected area (ESA)

ESC G (1B, 47 hex.)

ESA (87 hex.)

Wireless Station Action Marks the cursor position as the first of a string of character positions the wireless station can send to the host. Defines the cursor position as the last of a string of character fields the wireless station can send to the host.

Local Edit Mode Keys Keys with special functions in local edit mode are described in Table 8-48.

8-66

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

Page 203

SECTION 8

"

Programming

Table 8-48 Local Edit Mode Keys Key(s)

Function

Find

Advances cursor to the top margin, Column 1.

Tab

Advances cursor to the next tab stop. If in protected area, it advances to the next selectable field. If tab stop is selected, it advances to the next selectable field.

Insert here

Default mode is “insert.” The key toggles between insert and overstrike. If in insert mode, all following characters in the field are shifted right one position. If the field is full the last character is deleted.

Remove

If in protected area, wireless station beeps and the cursor advances to the first position of the next selectable field. If no selectable field is found, it advances to the bottom margin (the default is Row 24, Column 80). If in unprotected field, the field is cleared and the cursor is positioned to the beginning of the selectable field.

Prev screen

Ignores this key.

Next screen

Ignores this key.

Select

Ignores this key.

Backspace

Moves cursor one position to the left until it reaches the left margin.

Delete

Deletes the previous selectable character.

A--Z, 0--9, If one of these keys is pressed while in a proAuxiliary keypad tected area, the wireless station beeps, advances the cursor to the next selectable field, and enters the characters. If no other selectable field is found, the cursor advances to the bottom margin.

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

8-67

Page 204

SECTION 8

"

Programming

Table 8-48 (Continued) Local Edit Mode Keys Key(s)

Function

Backtab

Cursor moves back to the first occurrence of the following: " "

"

"

Cursor

[Y]

[B]

8-68

Previous tab stop. Beginning of the current unprotected field. Beginning of the previous unprotected field. Beginning of scrolling region. (Also called top margin.)

Cursor moves up one line until it reaches the top margin. The wireless station beeps when the cursor reaches the top margin. Cursor moves down one line until it reaches the bottom margin. The wireless station beeps when the cursor reaches the bottom margin.

["]

Cursor moves right one character position until it reaches the right margin. The wireless station beeps when the cursor reaches the right margin.

[A]

Cursor moves left one character position until it reaches the left margin. The wireless station beeps when the cursor reaches the left margin.

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

Page 205

SECTION 8

"

Programming

Scanning in Local Edit Mode When scanning is enabled, data from the scanner is placed into the field where the cursor is located. If the cursor is not in an input field, the data from the scanner is placed into the next input field. If the data from the scanner fills the first input field, the remaining characters are placed into the next input field. When the bar code does not fill the input field, the cursor stays where it ended. If autotab scanning is enabled, the cursor is placed at the beginning of the next input field. If not next input field is found, extra data will be lost.

Set Transmit Termination Character (DECTTC) The wireless station supports the set transmit termination character (DECTTC) control function. Use the control function to select a character to indicate the end of a block transmission. You do not need to use an end-of-block character. The wireless station sends the end-of-block character to the host at the end of each block transmission. The control sequence is: CSI Ps ê Ps is the end-of-block character in the following chart. Ps End-of-Block Character 0 (default) No character (DECTTC disabled)

Wireless Station Action

1

FF (0C hexadecimal)

Form feed

2

ETX (03 hexadecimal)

End of text

3

EOT (04 hexadecimal)

End of transmission

4

CR (0D hexadecimal)

Carriage return

5

DC3 (13 hexadecimal)

XOFF

VT220/ANSI Terminal Emulation Programmer’s Reference Guide

8-69

Page 206

SECTION 8

"

Programming

Use an extended form of DECTTC to select a string of characters to indicate the end of a block. The extended form uses decimal codes to represent characters. You can use the extended form to send a control function at the end of a block transmission, instead of a single character. You can send a control sequence of up to six characters (Pn1 through Pn6) at the end of a block. The control sequence is: CSI ? Pn1 ; ¼ Pn6 ê Pn1 through Pn6 are decimal codes for characters you can define as end-of-block. For example, the decimal code for ESC is 27 (1B hexadecimal). A code outside the range of 0 to 254 is ignored. The tables on pages 8-4 and 8-8 contain decimal codes for characters. For example, to send the default code of the PF1 key on the wireless station’s numeric keypad at the end of a block transmission, use the following procedure. 1. The PF1 key sends this default code: ESC O P 2. Translate each character in the sequence to decimal code. ASCII characters: ESC O P Decimal codes: 27 79 80 3. Insert the decimal codes into the extended DECTTC sequence: CSI ? 27 ; 79 ; 80 ê

8-70

VT220/ANSI Terminal Emulation Programmer’s Reference Guide