Page 231
SECTION 7
Extended Commands
CC Byte 1 Control Character Byte 1 (CC Byte 1) implementation differs among the terminals. Table 7-8 and Table 7-9 show the CC Byte 1 options for scanning. 6400 Computers do not support HP Wand Select. A “b” indicates a 1-byte space. Table 7-8 CC Byte 1 Options Supported by Characters (2415, 2425, 2435A, 2455, 248X Terminals) Line 1, Column 4 No Change From Current Setting CC Byte 1 Laser Disable Scanner 0 1 2 3 4 5 6 7 8 9 A B C D E F b x x x x x x x x x x
Table 7-9 CC Byte 1 Options Supported by Characters (6400, 5020, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 4 Redundancy Laser No Redundancy CC Byte 1 HP Wand Select 0 1 2 3 4 5 6 7 8 9 A B C D E F b x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
Disable scanner. No change from current setting. TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
7-17
Page 232
SECTION 7
Extended Commands
CC Byte 2 CC Byte 2 implementation differs among the types of terminals. Table 7-10 and Table 7-11 show CC Byte 2 options. Note that “b” indicates a 1-byte space. Table 7-10 CC Byte 2 Options Supported by Characters (2415, 2425, 2435A, 2455, 248X Terminals) Line 1, Column 5 CC Byte 2
Scan Termination Character
0–3 4–7 8–F b
None Auto Enter Scan Auto Tab Scan No change from current setting Table 7-11 CC Byte 2 Options Supported by Characters (6400, 5020, 5055, 59XX, 17XX, 11XX Terminals)
Line 1, Column 5 CC Byte 2
Scan Termination Character
0 1 2 3 4 5 6 7 8 9 A B C D E F
None
7-18
Modulo 10 Check Digit x x
[Enter] key x x [Tab] key
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide x x x x
Page 233
SECTION 7
Extended Commands
CC Byte 3 Note that “b” indicates a 1-byte space. Table 7-12 CC Byte 3 Options Supported by Characters (6400, 5020, 5055, 59XX, 17XX, 11XX Terminals Line 1, Column 6 CC Byte 3 0 1 2 3 4 5 6 7 8 9 A B C D E F b
Enable Stream Scanning
Reserved
Return Bar Code Type
Bar Code Concatenated x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x No change from current setting x
Bar Code Length Bar Code Length sets the minimum and maximum character lengths for all types of bar codes scanned (Table 7-13). Setting the minimum and maximum values to their optimum can increase scanning performance. If the terminal scans bar codes that are outside the minimum and maximum value, the terminal ignores the bar code. Note that a “b” indicates a 1-byte space. Table 7-13 Bar Code Length (6400, 5020, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 7--10 Column Character and Description 7--8 9--10
XX=Bar code length. Maximum length: 99. bb=No change from current setting XX=Bar code length. Minimum length: 00. bb=No change from current setting
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
7-19
Page 234
SECTION 7
Extended Commands
UPC " NOTE:
Use the UPC command to select the combinations of characters listed in Table 7-14. 6400 Computers do not support UPC-E Number System 1. Note that a “b” indicates a 1-byte space. Table 7-14 UPC Bar Code Characters (6400, 5020, 5055, 59XX, 17XX, 11XX Terminals) Character
UPC-E # System 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 b
Expand UPC-E to UPC-A
UPC-E # System 0
Add-ons
UPC-A x x x x x x x x x x x x x x x x
Disables all. x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x No change from current setting x
EAN Algorithms Use EAN Algorithms to select combinations of EAN options (Table 7-15). Note that a “b” is a 1-byte space. Table 7-15 EAN Algorithms (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 12 Character
Description
0 1 2 3 b
EAN disabled EAN with Add-ons enabled EAN enabled EAN and EAN with Add-ons enabled No change from current setting
7-20
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Page 235
SECTION 7
Extended Commands
Code 39 Code 39 (Table 7-16) sets the scanner to read simple Code 39 bar codes that do not include extended or encoded sequences. Note that a “b” is a 1-byte space. Extended Code 39 is a superset of Code 39 and scans all regular Code 39 bar codes. You cannot select both Code 39 and Extended Code 39. Encoded Code 39 combines key presses with normal bar code data. Appendix A contains Encoded Code 39 sequences. Table 7-16 Code 39 Algorithms Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 13 Character
Description
0 1 2 3 b
Code 39 disabled Encoded Code 39 enabled Extended Code 39 enabled Code 39 enabled No change from current setting
Plessey If the Plessey bar code scanning algorithm is enabled, set its check digits (Table 7-17) according to your requirements. Refer to the manufacturer ’s bar code specifications for more information on check digits. 6400 Computers do not support Plessey alpha characters. Note that a “b” indicates a 1-byte space. Table 7-17 Plessey Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 14 Character Description 0 1 b
Plessey disabled Plessey enabled No change from current setting
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
7-21
Page 236
SECTION 7
Extended Commands
The dots in Table 7-18 indicate the Plessey check digits the characters support. Table 7-18 Plessey Check Digit Characters Line 1, Column 15 Character 0 1 2 3 4 5 6 7 8 9 A B C D E F b
Keep 2nd Digit Check
Do Not Validate 1st Check Digit
Keep 1st Check Digit
Mod 10 1st Check Digit
Mod 11 1st Check Digit x x x x x x x x x x x x x x x x x x x x x x x x x x No change from current setting x x x x x x x x x x x x x x
Codabar The Codabar options (Codabar and ABC Codabar) are mutually exclusive coding algorithms and cannot be selected at the same time. Note that a “b” indicates a 1-byte space. Table 7-19 Codabar Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 16 Character
Description
0 1 2 b
Codabar disabled Codabar enabled ABC Codabar enabled No change from current setting
Code 11 Table 7-20 lists Code 11 characters. Note that a “b” indicates a 1-byte space. Table 7-20 Code 11 Characters (59XX, 17XX, 11XX Terminals) Line 1, Column 17
7-22
Character
Description
0 1 b
Code 11 disabled Code 11 enabled No change from current setting
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Page 237
SECTION 7
Extended Commands
Code 93 Code 93 and Code 128 options can be enabled. Note that a “b” indicates a 1-byte space. Table 7-21 Code 93 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 18 Character
Description
0 1 b
Code 93 disabled Code 93 enabled No change from current setting
Code 128 Table 7-22 lists Code 128 characters. Note that a “b” indicates a 1-byte space. Table 7-22 Code 128 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 19 Character
Description
0 1 b
Code 128 disabled Code 128 enabled No change from current setting
Straight or Computer Identics 2of5 If the Straight or Computer Identics bar code is enabled, select the maximum and minimum lengths and the first and second fixed bar code lengths according to your requirements (Table 7-23). Note that a “b” indicates a 1-byte space. Refer to the manufacturer ’s bar code specifications for more information. Table 7-23 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 20--28 Column Character 20 21--22 23--24 25--26 27--28
0=Straight and Computer Identics 2 of 5 disabled; 1=Computer Identics 2 of 5 enabled; 2=Straight 2 of 5 enabled; b=No change from current setting XX=maximum length Straight or Computer Identics 2 of 5; bb=No change from current setting XX=minimum length Straight or Computer Identics 2 of 5; bb=No change from current setting XX=1st fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting XX=2nd fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
7-23
Page 238
SECTION 7
Extended Commands
Interleaved 2 of 5 If Interleaved 2 of 5 is enabled, select the maximum and minimum lengths and the first and second fixed bar code lengths according to requirements (Table 7-24). Note that a “b” indicates a 1-byte space. Refer to the manufacturer ’s bar code specifications for more information. Table 7-24 Interleaved 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 29--37 Column Character 29 30--31 32--33 34--35 36--37
0=Interleaved 2 of 5 disabled; 1=Interleaved 2 of 5 enabled; b=No change from current setting XX=maximum length Interleaved 2 of 5; bb=No change from current setting XX=minimum length Interleaved 2 of 5; bb=No change from current setting XX=1st fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting XX=2nd fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting
Return Codes for Scan Bar Code The Scan Bar Code Parameters return code is the status sent to the host computer; the code indicates if the extended command was successful. The terminal returns data and the extended command’s status to the host computer in the \\X<CR> format where X is the return code listed in the following chart. The terminal simulates the [ENTER] key to return a value to the host computer. If a hexadecimal number is entered wrong, the return code defaults to “0.”
7-24
Code
Description
0 1
Good status, transaction complete Bad status, transaction incomplete
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide