Page 121

SECTION 4

Using the Terminal Emulation Menus

7) More (Main Menu 2) Select 7) More to open the Main Menu 2 screen.

Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu

3) Cloning Opts is for 59XX, 17XX, 11XX 4) Session Menu is for 6400, 5020, 5055, 17XX, 11XX

1) Keyboard Opts

Use 1) Keyboard Opts o 1) Type-Ahead to key in information when the terminal cannot immediately send data to the host computer. 1) Type-Ahead enters information when the terminal cannot immediately send data to the host. Keyboard Opts 1) Type - Ahead

This stores keystrokes after the Input Inhibited annunciator (below) appears on the status line, and then saves them for the next input field. Type-ahead is enabled by default.

X

Input Inhibited annunciator

2) Save Parms (Parameters)

Use 2) Save Parms to retain the changes made to TE configuration settings. When saved, the changes become the default settings for the terminal. " NOTE:

Use this option sparingly. Each it is used, additional memory space is occupied because previously saved changes are not erased. The memory cannot be recovered on 11XX, 17XX, and 59XX Terminals without reflashing.

Ensure that the parameters are correct before choosing 2) Save Parms. When selected, you are prompted to enter a seven-character password. The default password is CR52401; which can be altered with a custom configuration to be a string of 1 to 10 characters long. After you enter the correct password, your changes are written to Flash. If an error is made or the incorrect password is entered, the terminal will return to 2) Save Parms screen without saving your entries.

Save Parms Enter Password: > . . . . . . .

Save Parms Working Please Wait ........

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

4-51

Page 122

SECTION 4

Using the Terminal Emulation Menus

3) Cloning Opts (59XX, 17XX, 11XX) " NOTE:

3) Cloning Opts is disabled for 59XX Terminals.

These options transfer the application program or parameter settings from one terminal to another. All three choices are password-protected, with CR52401 as the default password. To perform this function you need a cloning cable and both terminals set for cloning. Cloning Opts 1) Clone Prgms 2) Clone Parms 3) Receive Parms

1. Connect the two terminals together using the cloning cable. Use cable P/N: 216-911-001, with radio terminals containing 12-volt Flash (Figure 4-1) for connecting with the NC1100 Power Supply and Charger (see Figure 4-2). 2. Plug the NC1100 Power Supply and Charger into an ac outlet. Use cable P/N: 216-909-001, with radio terminals containing 5-volt Flash. You may use the 12-volt Flash cable, but this is optional. 3. Turn on the source terminal from which to copy the application. 4. Press 3) Cloning Opts, then 1) Clone Prgms. 5. Key in the password. 6. Hold down the [I] key while turning on the terminal receiving the program. The application program will be copied into the receiving terminal. To Source Terminal

To NC1100 Charger

To Receiving Terminal

12-Volt Cable (P/N: 216-911-001)

To Source Terminal

To Receiving Terminal 5-Volt Cable (P/N: 216-909-001)

Figure 4-1 FLASH Cloning Cable Connections

4-52

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 123

SECTION 4

Using the Terminal Emulation Menus

To clone parameters from one terminal to another, first ensure the desired parameters are already set in the terminal you wish to transfer from. Then: 1. Connect the terminals together using the cloning cable. Data Terminals with 12-volt FLASH use P/N: 216-911-001. Data Terminals with 5-volt FLASH use P/N: 216-909-001. 2. With both terminals turned ON, press 3) Cloning Opts on both terminals. 3. On the source terminal (the one containing the parameters to copy from), press 2) Clone Parms. 4. On the receiving terminal, press 3) Receive Parms. If using the cable that requires the NC1100 Power Supply and Charger, make sure it is connected to the NC1100 Power Supply and Charger.

Figure 4-2 Cloning Cable Connection with NC1100 Power Supply

4) Session Menu (6400, 5055, 5020, 59XX, 17XX, 11XX)

4) Session Menu defines different host communication sessions and designates a “hot key” that allows switching quickly between the different sessions. 1) Switch Use this option to change the current session. The current (or intended) session must be identified (or designated) before setting Parameters. 2) Set Hot Key (available on units supporting session-switching) Displays the current hot key. Use the up and down keys to view the available choices. Press [Enter] to designate a key for the hot key. 3) Copy Setup (password-protected) This copies parameters from the background session to the current session. Session Menu 1) Switch 2) Set Hot Key 3) Copy Setup

Select Session Use Cursor Up And Down Keys To Adjust

[1]

Session: x Host: xxxx <Datastream>.....xxx

[2]

Set Hot Key Use Cursor Up And Down Keys To Adjust < xx >

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

4-53

Page 124

SECTION 4

Using the Terminal Emulation Menus

Restarting Terminal Emulation " NOTE:

The reset firmware bar code is not supported on the 5020, 59XX, 17XX, or 11XX Terminals. Instead, do the cold-start function to exit the TE application and return to the Windows CE main menu.

You need to restart your TE application if you are having problems or if you want to reconnect to the host with a new configuration. Restarting your TE application also clears the auto-login information, preventing another user from establishing a TE session using your login information. You can restart your TE application by either scanning the following Reset Firmware bar code or by using the 6) Cold Start option in the TE configuration Main Menu. Both methods reset all terminal firmware and the application and run the application in a new session. Reset Firmware

*/M.* *--.*

The terminal restarts your TE application using the configuration saved in CONFIG.DAT, or follow this procedure: 1. At the third initialization screen or anywhere in a TE session, access the Main Menu by pressing the appropriate key combination (see page 1-3). COPR. 1991-2001 INTERMEC. ALL RIGHTS RESERVED V<version number> <release date>

TE 2000(TM)

<program name> <version> Host: <host name> <emulation type>

" NOTE:

If you are not connected to the DCS 300 or host, or have problems accessing the Main Menu, reset your terminal to go to the initialization screens.

2. Select 1) Setup Parms, then enter the “cr52401” password. Do not press Enter. 3. Select 6) Cold Start, press [Y] when prompted to restart, then start using the application or change the TE configuration. See the terminal’s user guide for information on how to recover from a lock-up condition. 4-54

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 125

SECTION 4

Using the Terminal Emulation Menus

Trakker Antares (2415, 2425, 2435A, 2455, 248X) The following instructions are specific for 2415, 2425, 2435A, 2455, and 248X Terminals. You can configure several options for VT/ANSI TE on your Trakker Antares R Terminal, including: " UDP Plus or TCP/IP communications " VT/ANSI options " Main Menu password " NOTE:

You can also set the password for UDP Plus Terminals from the DCS 300.

You can access the TE configuration menus when the initialization screens appear or once you establish a TE session. The TE initialization screens appear each time you reboot the terminal or restart your application. " NOTE:

Some parameters for 2415, 2425, 2435A, 2455, and 248X Terminals are available through the TRAKKER Antares 2400 Menu System. They are not reproduced in the TE configuration menus. For more information about the menu system, refer to the terminal’s user manual.

6400 Computer The terminal emulation screens support terminals running Intermec Terminal Emulation or 6400 TCP/IP software. This section describes the menus used to set operating and scanning parameters for the hand-held computer. Additional information can be found in the technical overview for your emulation program. " NOTE:

Ensure there is a fully-charged battery pack in the 6400 Computer before setting parameters.

Opening the Main Menu The Main Menu is the first screen displayed when you open the computer menus. All other menus are accessed from the Main Menu. To open the Main Menu, press the [Yellow] shift, then the [Blue] shift key. Briefly, these keys generally operate as: " [Blue] shift, for functions labeled by blue legends above the keys. " [Green] shift, for functions labeled by green legends above the keys. " [Yellow] shift, for functions labeled by yellow legends above the keys. " [Blue], then [Green] shift is CAPS LOCK. " [Blue], then [Yellow] shift is Alphabetic Lock (6400 Computer 41-key units). " [Yellow], then [Blue] shift is Terminal Emulation menus; your particular emulation software probably treat the keys for contrast control, backlighting and other functions differently.

To Exit Emulation Mode and Return to DOS Do a cold-restart to exit the current emulation program and return back to the DOS keyboard layout. Press [Y], press [Enter] several times to put you at the DOS C:\ prompt. To exit to the beginning of the current emulation, press and hold the [Blue] and [Yellow] shift keys, and both [ENT] keys to do the hard reset. TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

4-55

Page 126

Using the Terminal Emulation Menus

SECTION 4

5055 Data Collection PC B CAUTION:

If you are running terminal emulations and ever update the DOS load on the internal SanDisk IDE drive on the 5055 PC, be aware that when updating 50DS1000, avoid copying the CONFIG.SYS and AUTOEXEC.BAT files. The new versions of these two files may interfere with existing applications, such as Terminal Emulations. If affected, Terminal Emulations will automatically run on boot up. In all other situations, do copy the CONFIG.SYS and AUTOEXEC.BAT files.

This section contains information about the terminal emulations with keyboards supported for the Intermec R 5055 Data Collection PC. The 5055 PC supports terminal emulations with rugged keyboards. FWP650H0 is DOS-based and is not compatible with Windows DOS prompts. An external PS/2-compatible keyboard is required for configuring and using terminal emulations. Terminal emulation font files are needed to generate the various character fonts. See the related terminal emulation programmer ’s reference guide for additional information.

Programs Used to Create Terminal Emulation Menus The Terminal Emulation Menu Screens are provided to support terminals running Intermec Terminal Emulation software. This section describes the menus that set operating and scanning parameters for the 5055 PC. Additional information can be found in the programmer ’s guide or technical overview for your emulation program. When you power on the 5055 PC, the AUTOEXEC.BAT file executes the following programs, in sequential order, to create the terminal emulation menus. Listed are their descriptions. LSL Creates the link layer for the protocol stack. rl2pcm Includes the Proxim radio driver for the Proxim RangeLAN2 radio, or wvlan43 Includes the WaveLAN/IEEE radio driver for the 802.11b HR radio. 6500ikps Installs multitasking, beeper, and key remapping TSRs. wtppkt Includes the WTP Packet driver program if a WTP link accesses the host computer, or ethdrv and odipkt Includes the Ethernet and ODI Packer driver programs if a TCP/IP link and a controller are used to gain access to the host computer. 65scn7b –c1 Activates the scanner driver. 6500dbcs Intercepts INT10 and display characters on the display. fwp650h0 Activates the terminal emulation program. 4-56

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 127

SECTION 4

Using the Terminal Emulation Menus

Press <Alt>, then [M] on the external keyboard to access the setup menus. " NOTE:

On terminal emulation keyboards, use the yellow key in place of the <Alt> key. For example, to access the Setup Menus, press <Yellow>, then [M].

Opening the Main Menu The Main Menu is the first screen displayed when you open the computer menus. All other menus are accessed from the Main Menu. To open the Main Menu, press the yellow shift, then the blue shift (MENU) key. Briefly, these keys generally operate as: " " " " "

[Blue] shift, for functions labeled by blue legends above the keys. [Green] shift, for functions labeled by green legends above the keys. [Yellow] shift, for functions labeled by yellow legends above the keys. [Blue], then [Green] shift is CAPS LOCK. [Yellow], then [Blue] shift is Terminal Emulation menus; your particular emulation software probably treat the keys for contrast control, backlighting and other functions differently.

To Exit Emulation Mode and Return to DOS Do a cold-restart to exit the current emulation program and return back to the DOS keyboard layout. Press [Y], then press [Enter] several times to arrive at the DOS C:\ prompt. To exit to the beginning of the current emulation, press and hold the [Blue] and [Yellow] shift keys, and both [ENT] keys to do the hard reset.

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

4-57

Page 128

Using the Terminal Emulation Menus

4-58

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

SECTION 4