The text of a manual · part 12 of 33
TE 2000 VT/ANSI Terminal Emulation Programmer's Guide: Section 4: Using the Terminal Emulation Menus, pages 81 to 90
Pages 81 to 90 of 278, from TE 2000 VT/ANSI Terminal Emulation Programmer's Guide
The original document is the PDF (4.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 81
SECTION 4
Using the Terminal Emulation Menus
2) RTC/WTP (6400, 5055, 59XX, 17XX, 11XX)
Use 2) RTC/WTP to set, view, or change the terminal ID. This number allows the host computer to identify individual terminals in the radio data network. Each terminal must have a unique number in the same network. The 1) Radio Setup and 2) Host/Cntl menus are shown on the following pages. Depending on which option you are exercising you will either advance to the WTP Stack settings or the TCP/IP Stack settings. WTP Settings
Use the numeric keys on the terminal keyboard or 5055 external keyboard to modify its ID. Enter a number between 0–126, then press [Enter] to go to the 2) Host/Cntl menus. The LAN ID number can be 0--255 depending on the radio being used. With the RM60/70 radio, the number can be 0--255; with the RM80/90 radio, the range is 0--15. Your terminal only communicates with equipment using the same ID number that you assigned to your LAN. If you enter a LAN ID number different from what is configured in the NET.CFG file you get the following message. If this happens, the system modifies NET.CFG, which is used by WTPPKT.EXE on initializing the terminal.
LAN ID changed Need to reboot to take effect.
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
4-11
Page 82
SECTION 4
Using the Terminal Emulation Menus
WTP Stack Options Controller Type 1) 2) RTC/WTP 3)
[2] Host/Cntl 1) Radio Setup 2) Host/Cntl
[1]
For 802.11 Radios Only
[2]
Go to Host/Cntl on the next page
For Non 802.11 Radios
Radio Setup Network Name
Radio Setup LAN xxxx Enter up to 34 characters for a name xx
ENTER
Radio Setup Radio Config#
Only if a “radio cfg“ file is present on the terminal.
ENTER (5055 -- continue to Host/Cntl setups) Set Mode/Channel is for RM60 (902 MHz) radios
Set Frequency Use Cursor Up and Down Keys To Adjust
Set Mode/Channel Use Cursor Up and Down Keys To Adjust DS xxxx channel xx xxxxxxxxx ENTER (continue to Host/Cntl setups)
4-12
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Set Frequency is for Synthesized UHF radios
Page 83
SECTION 4
Using the Terminal Emulation Menus
ENTER
Host/Cntl Settings
Host/Cntl 1) CNTL A 2) CNTL B 3) CNTL C
ENTER
DONE
ENTER
Controller (x) Enter Unit Number xxx
ENTER Controller (x) (cust emulation) unit # xxx Host Name Enter up to 16 characters/Numbers for a name. ENTER Emulation (x) Enter Unit 1) Native 2) 3270 3) 5250 4) VT/ANSI
ENTER
Telnet (x) 1) Enabled 2) Disabled
ENTER
3) Direct Connect (6400, 5055)
The first option if exercising TCP/IP stack is 1) Radio Setup. Once selected, enter your network name or LAN ID. If using a 902 MHz radio module, use the up and down arrows to pick the Direct Sequence (DS) and Channel configuration. If using a Synthesized UHF radio, select the possible frequencies for your radio module from the list. The 2) Host/Cntl option changes the host setting to designate up to three host computers for each 6400 Computer or 5055 PC. Each host is assigned a separate priority level (1, 2, or 3). When powered on, the 6400 Computer or 5055 PC seeks host A. If host A is not available, the 6400 Computer or 5055 PC seeks host B; if host B is not available, the unit attempts to log onto host C. TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
4-13
Page 84
SECTION 4
Using the Terminal Emulation Menus
When designating additional hosts for the 6400 Computer or 5055 PC, you must: "
"
" NOTE:
Tell the 6400 Computer or 5055 PC the host type of each host computer: (3270, 5250, or VT/ANSI). Tell the 6400 Computer or 5055 PC the name of each host.
Selections in these menus apply only to the current session. Use 4) Session Menu to verify or change the current session.
TCP/IP Stack Options Direct 1) Radio Setup 2) Host Setup
[1]
For 802.11 Radios Only
[2]
Host 1) Host A 2) Host B 3) Host C
For Non 802.11 Radios
Radio Setup Network Name
Radio Setup LAN
ENTER Host Name (x) Host emulation xxxx Enter up to 34 characters for a name xx
Host Name Enter up to 16 character/numbers for a name
ENTER
ENTER Radio Setup Radio Config#
Only if a “radio cfg“ file is present on the terminal.
Emulation (x) 1) 2) 3270 3) 5250 4) VT/ANSI
ENTER (5055 -- continue to Host/Cntl setups) Set Mode/Channel is for RM60 (902 MHz) radios
Set Mode/Channel Use Cursor Up and Down Keys To Adjust DS xxxx channel xx
Set Frequency Use Cursor Up and Down Keys To Adjust
Set Frequency is for Synthesized UHF radios xxxxxxxxx
ENTER (continue to Host/Cntl setups)
4-14
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Page 85
SECTION 4
Using the Terminal Emulation Menus
3) Direct Connect (2415, 2425, 2435A, 2455, 248X, 5020 with TE/IP)
To set 3) Direct Connect options, select 3) Direct Connect, 2) Host Setup, then 1) Host A. Use the Emulation (A) option to tell the terminal the type of each host computer. Default is 3270. " NOTE:
You can also set the emulation type through the 2) Data Stream option on the 3) Protocol Opts menu. Controller Type 1) 2) 3) Direct Connect
[3] Direct Connect
1) 2) Host Setup
[2] Host 1) Host A 2) Host B 3) Host C
2) Host B and 3) Host C are for 5020
ENTER Host Name (x) Host emulation Host Name Enter up to 16 character/numbers for a name ENTER Emulation<A, B, or C> 1) 2) 3270 3) 5250 4) VT/ANSI
2) Code39 Encoded (2415, 2425, 2435A, 2455, 248X, 5020)
By default, 2) Code39 Encoded is disabled. When you enable this option, the key press sequences for Encoded Code 39 are used. For more information, see Appendix A, “Bar Code Scanning.”
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
4-15
Page 86
SECTION 4
Using the Terminal Emulation Menus
2) Barcode Parms (6400, 5055, 59XX, 17XX, 11XX) The 2) Bar Code Parms (parameters) menus designate: " " "
"
If you are using a bar code scanner Scan options The bar code symbologies to use (the terminal can only decode the enabled bar code symbologies) Options for each enabled bar code symbology, such as the minimum and maximum bar code lengths
1) Scanner Type
Use the 1) Scanner Type menu to designate the type of bar code scanner. To make a selection, press the numeric key corresponding to the desired option, then press [Enter] to access the 2) Scan Options menu.
Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect
" NOTE:
2) Wand, 4) Wand Emulate, and 5) Auto Detect are for 59XX, 17XX, 11XX
If 1) No Scanner is chosen, the remaining scanner and bar code options can be set. Then, if a scanner is used at a later time, only the scanner type needs to be designated. Selected options are highlighted on the display. Press a key corresponding to that option to deselect a selected option. 2) Scan Options
Use the 2) Scan Options menu to designate how the terminal handles scanned bar codes. Press [Enter] to advance to additional 2) Scan Options menus. Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More
1) Redundancy and 4) BC Type Char are for 6400, 59XX, 17XX, 11XX
1) Redundancy (6400, 59XX, 17XX, 11XX) This option requires two identical scans of a bar code, one right after another, before the terminal accepts the scan as valid. 2) Mod 10 Check When you select this option, a check digit is added at the end of the bar code after a good read. This is a variation of the modulus 10 formula and is used infrequently. Mod 10 checks the validity of a bar code number, to ensure the number is within a set of numbers valid for its symbology. “Mod” is the remainder of a division of two numbers. The bar code number is divided by 10, until the number (or modulus) is less than 10. If the modulus subtracted from 10 (remainder) is equal to zero, then the bar code number is valid. 4-16
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Page 87
SECTION 4
Using the Terminal Emulation Menus
3) Concatenate Each bar code read is added to the end of the previous bar code read until the 6400 Computer or 5055 PC meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. 4) BC Type Char (6400, 59XX, 17XX, 11XX) This option adds a character associated with the bar code type at the beginning of the scanned bar code. 5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped. 6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. 7) More This brings you additional scanning options that adjust scanning timeout and characters sent before and after the scanned data. 1) Scan Timeout (59XX, 17XX, 11XX) Use this option to adjust the scanning timeout period from 1 to 200 seconds. When using a proximity-detect scanner, you can shorten the timeout period to speed up scanning while also reducing the duration of errant scans. With a long-range scanner, you may want to increase the timeout period to ensure sufficient aiming time.
Scan Timeout Seconds XXX
2) Scan PreChar and 3) Scan PostChar Enter a hexadecimal value from 00--FF for the character to be sent preceding the scanned data or after the scanned data. The value of 20h means that pre- or post-characters are not sent.
Scan Options 1) Scan Timeout 2) Scan PreChar 3) Scan PostChar
1) Scan Timeout is for 59XX, 17XX, 11XX
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
4-17
Page 88
SECTION 4
Using the Terminal Emulation Menus
Scan Options to Enable Bar Codes
There are menus of options to enable (or disable) various bar code symbologies. To enable a bar code, press the numeric key corresponding to the number of the bar code symbology (as shown on the menu), then press [Enter]. After enabling a particular bar code, options may have to be selected for the bar code. After selecting the desired options, set the length requirements (such as minimum and maximum length, fixed lengths, leading and trailing character options, etc.). Once the length requirements are set, the terminal returns to the same 2) Scan Options menu. Choose another bar code symbology from that menu or press [Enter] to advance to the next Scan Options menu. Scan Options 1) UPC 2) EAN 3) Code 39 4) Code 128 5) Codabar
4) Sys 1 UPCE is for 6400, 17XX, 11XX
6) Relax Std is for 59XX, 17XX, 11XX
UPC 1) Enabled 2) Add-On 2 3) Add-On 5 4) Sys 1 UPCE 5) Sys 0 UPCE 6) Expand E To A
Code 39 1) Enabled 2) Chk Digit 3) Extended 4) Encoded 5) Auto-Encoded 6) Relax Std 7) Full ASCII
[1]
[3]
[2]
[4]
EAN 1) Enabled 2) Add-On 2 3) Add-On 5 4) Expand 8 To 13
Code 128 1) Enabled 2) UCC/EAN 3) No UCC Type 4) UCC F1 Value
[6] RELAX CODE 39 1) Quiet zone 2) Data Decode 3) Element Decode 4) START Decode
4-18
[5]
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
Codabar 1) Codabar 2) ABC Codabar
2) ABC Codabar is for 59XX, 17XX, 11XX
Page 89
SECTION 4
Using the Terminal Emulation Menus
Scan Options of Additional Bar Codes
This menu offers additional bar code selections. After enabling a bar code symbology, various options, including length can be set. When all options are set, the display returns to the 2) Scan Options menu. This menu and the bar code symbologies to be enabled are shown below. When all needed bar code symbologies are enabled, press [Enter] to return to the first 1) Scan Options menu. Press [Enter] again to back out and return to the 1) Set-up Parms menu.
5) Code 11 is for 59XX, 17XX, 11XX
Plessey 1) Enabled 2) MOD10 Chk 3) MOD11 Chk
Int 2 of 5 1) Enabled 2) Chk Digit
Code 11 1) Enabled 2) Chk Dig 1 3) Chk Dig 2
Scan Options 2 1) Plessey 2) Str 2 of 5 3) Int 2 of 5 4) CI 2 of 5 5) Code 11 6) Code 93
[1]
[3]
[5]
[2]
Str 2 of 5 1) Enabled 2) Disabled
[4]
CI 2 of 5 1) Enabled 2) Disabled
[6]
Code 93 1) Enabled 2) Disabled
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide
4-19
Page 90
SECTION 4
Using the Terminal Emulation Menus
Lengths Options
The Lengths Options menus determine the maximum and minimum length for a specific bar code symbology. Setting the length of enabled bar codes helps the terminal determine if a scanned bar code is valid and improves response time. The length options must be set for each enabled bar code. 1. Key in the maximum length (0–99), then press [Enter]. 2. Key in the minimum length (0–99), then press [Enter]. 3. Fixed-length entries override the maximum and minimum length entries (minimum and maximum are used for chosen codes). If fixed lengths are not needed for the enabled bar code, enter zero (0). Enter the fixed length (0–99), then press [Enter]. Up to four prompts to set another fixed length will appear. Enter zero (0) for the unused fixed lengths. Note that I 2 of 5 only supports fixed lengths 1 and 2. Entries in 3 and 4 are ignored. 4. Enter the number of characters (0–15) to drop from the front (leading) edge of the scanned bar code, then press [Enter]. 5. Enter the number of characters (0–15) to drop from the rear (trailing) edge of the scanned bar code, then press [Enter]. After all of the length options are set for the enabled bar code, the display returns to one of the 1) Scan Options menus (depending on which menu the bar code was enabled).
(bar code type) Max Length xx
4-20
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx
(bar code type) Max Length xx Min Length xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx Fix Length 4 xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx
(bar code type) Drop Leading xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx
(bar code type) Drop Leading xx Drop Trailing xx
TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide