For the Intermec 6400

Page 11

SECTION 1

"

General Information

Specifications Single Dock "

Weight: 3.65 lbs. (1.66 kg)

"

Dimensions: "

Length: 8 inches (20.32 cm)

"

Width:

"

"

Without cables 6 inches (15.24 cm) With cables 8.5 inches (21.59 cm)

Height: Dock only 8 inches (20.32 cm) Dock with hand-held computer 11.5 inches (29.21 cm)

Minimum vertical spacing between shelves: 17 inches (43.18 cm)

Multidock "

Weight: 22.25 lbs. (10.09 kg)

"

Dimensions: "

Length: 37 inches (93.98 cm)

"

Width:

"

"

Without cables 10.75 inches (27.31 cm) With cables 13.25 inches (29.21 cm)

Height: Dock only 8 inches (20.32 cm) Dock with hand-held computers 11.5 inches (29.21 cm)

Minimum vertical spacing between shelves: 17 inches (43.18 cm)

6400 Single and Multidock Installation Instructions 1-5

Page 12

SECTION 1

"

General Information

Connector Pin-Outs 8-Pin Interface Connector

7

5

3

1

8

6

4

2

Figure 1-3 Interface Connector Table 1-1 8-Pin Connector Pin-Outs

1-6

Pin

Signal Name

Function on Dock

I/O from Dock

1

BCLK

Battery Interface Clock

Input

2

DOCKPWR

12 Volt Charge Power

Output

3

GND

Ground

4

BDAT

Battery Interface Data

Input

5

TXD

Transmit Data

Input

6

RXD

Receive Data

Output

7

RTS

Request To Send

Input

8

CTS

Clear To Send

Output

6400 Single and Multidock Installation Instructions

Page 13

SECTION 1

"

General Information

Single Dock 9-Pin Male Serial Port The single dock RS-232 port, available on a DB9 male connector, is generated from the IrDA interface on your hand-held computer.It has no hardware handshake available and has the following signals. 1

2

3

4

5

6

7

8

9

Figure 1-4 Single Dock 9-Pin Male Connector Table 1-2 Single Dock 9-Pin Serial Port Connector Pin-Outs

Pin

Signal Name

Function

Standard Function on PC

I/O on Dock

1

NC

No Connect

Data Carrier Detect (DCD)

2

RXD

Receive Data

Receive Data

Input

3

TXD

Transmit Data

Transmit Data

Output

4

DTR

Forced Low

Data Terminal Ready

Output

5

GND

Ground

Ground

6

DSR

To Set Baud Rate

Data Send Ready

Input

7

RTS

Forced Low

Request To Send

Output

8

CTS

To Set Baud Rate

Clear To Send

Input

9

NC

No Connect

Ring Indicator

Use pin 6 and 8 of this RS-232 connector to set the baud rate of the IrDA controller located inside the single dock. The standard is to have the baud rate set at 9600. Table 1-3 on page 1-8 shows the baud rate for each combination of control lines. 6400 Single and Multidock Installation Instructions 1-7

Page 14

SECTION 1

"

General Information

Table 1-3 Baud Rate Setting

DSR Pin 6

CTS Pin 8

Baud Rate

1

1

9600

1

0

9600

0

1

19.2 K

0

0

115.2 K

Single Dock 25-Pin Male Serial Port Table 1-4 on page 1-9, shows the signals for the single dock RS-232/RS-485 port DB25 male connector. This connector will support the standard 25-pin RS-232 serial cables. The single port supports RS-485 operations when you use cable, Norand part number 226-231-001. This cable will ground the 485 enable line and provide two 9-pin connectors to connect to the standard RS-485 cables, Norand part number 226-103-xxx (xxx indicates length). Your sales team will help you determine the length you need for your installation. Two connectors are provided so that the RS-485 host and a powered RS-485 terminator (NPN: 226-257-001) can be connected, or the network can be continued through to another host computer or dock. For more information about using the powered terminator in your network design work with your Norand sales team.

25

13

14

1

Figure 1-5 Single Dock 25-Pin Male Connector

1-8

6400 Single and Multidock Installation Instructions

Page 15

SECTION 1

"

General Information

Table 1-4 Single Dock 25-Pin Serial Port Connector Pin-Outs

Pin

Signal Name

Function

1

GND

Ground

2

TXD

Transmit Data

3

RXD

Receive Data

4

RTS

Ready To Send

5

CTS

Clear To Send

6

DSR

Data Set Ready

7

GND

Ground

8

DCD

Data Carrier Detect

9

NC

No Connect

10

NC

No Connect

11

485+

RS-485 Positive Side

12

NC

No Connect

13

NC

No Connect

14

NC

No Connect

15

NC

No Connect

16

NC

No Connect

17

NC

No Connect

18

485-

RS-485 Negative Side

19

485 Enable

20

DTR

Data Terminal Ready

21

NC

No Connect

22

NC

No Connect

23

NC

No Connect

24

NC

No Connect

25

NC

No Connect

Comments

Connected to pin 20 DTR

If grounded 485 Enabled Connected to pin 6 DSR

6400 Single and Multidock Installation Instructions 1-9

Page 16

SECTION 1

"

General Information

Multidock 9-Pin Female RS-485 Connector 5

4

3

2

1

9

8

7

6

Figure 1-6 Multidock 9-Pin Female RS-485 Connector Table 1-5 Multidock 9-Pin Connector Pin-Outs

1-10

Pin Signal Name

Function

1

NC

No Connect

2

485+

485 Positive Data Signal

I/O

3

485-

485 Negative Data Signal

I/O

4

NC

No Connect

5

NC

No Connect

6

NC

No Connect

7

NC

No Connect

8

NC

No Connect

9

NC

No Connect

6400 Single and Multidock Installation Instructions

I/O to Dock

Page 17

Section 2 Single and Multidock Installation "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Installation Guidelines The single and multidock can be placed (installed) on a desk, countertop, or mounted onto a structure. If your dock is to be installed on a desk or countertop, then plugging into a power source is about your only consideration for concern. Wall mounting your dock involves a suitable structure to hold the weight of one or several docking units. Wall mounting kits are available that contain the brackets and hardware necessary for this purpose. This instruction booklet contains the instructions for mounting single and multidocks.

Installation Guidelines Single and multidock units are intended to be installed and used in environments that remain at about room temperature opposed to high and low extremes. These docks are specifically not designed for use in these environments: "

Outdoor loading dock, or staging area

"

Walk-in coolers or other refrigerated storage areas

"

Over-heated areas such as incubation room

"

High-humidity environments

"

Confined, unventilated space such as a storage closet

"

Wherever chemical dust, fumes, or corrosives materials are present

Electrical Requirements The single and multidocks contain an autosensing (90-240) voltage power supply that uses the alternating current (ac) power from your 2-1

6400 Single and Multidock Installation Instructions

Page 18

SECTION 2

"

Single and Multidock Installation outlets. The docks come with a six foot universal power cord and therefore must located within that distance of an outlet. The outlets must be grounded (three-prong) and with sufficient current to carry the load for the number of docks per circuit breaker. If you are uploading and downloading data with the host computer you will need to have data jacks close by. You will also need to have communication cables for connecting the docks to the jacks. The connectors are identified in this booklet but cables are not provided in the installation kit.

6400 Single and Multidock Installation Instructions

2-2

Page 19

SECTION 2

"

Single and Multidock Installation

Electrical and Communication Connections Figures 2-1 and 2-2 show the connectors for the single and multidocks.

3 1 2

Back view 1. RS-232 or RS-485 serial port 2. RS-232 serial port 3. AC connector

Figure 2-1 Single Dock Connectors

1

2

Back view 1. RS-485 connectors 2. AC connector

Figure 2-2 Multi Dock Connectors

2-3

6400 Single and Multidock Installation Instructions

Page 20

SECTION 2

"

Single and Multidock Installation

Dock Installation The single dock is small and fairly lightweight, you can attach the dock the brackets first, and then install the complete assembly to the wall. Or, you can install the mounting brackets on the wall before attaching the single dock. Installing the mounting brackets first is probably the preferred method and therefore the instructions for that follow next.

Mounting Structure You can install the docks on most structures made of wood, concrete, or cinder block. Use anchors that will support the weight and are designed for the type of wall you will be using. Some anchor selection guidelines are: "

"

Concrete structures use metal expansion anchors. Plastic anchors or dowels will not hold. Cinder block walls, use 1/4 inch or larger toggle bolts into the hollow portions of the blocks. Expansion anchors or dowels pull loose over time.

6400 Single and Multidock Installation Instructions

2-4