The text of a manual · part 2 of 3
6400 Single and Multidock Installation Instructions, pages 11 to 20
Pages 11 to 20 of 28
The original document is the PDF (466 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 11
SECTION 1
"
General Information
Specifications Single Dock "
Weight: 3.65 lbs. (1.66 kg)
"
Dimensions: "
Length: 8 inches (20.32 cm)
"
Width:
"
"
Without cables 6 inches (15.24 cm) With cables 8.5 inches (21.59 cm)
Height: Dock only 8 inches (20.32 cm) Dock with hand-held computer 11.5 inches (29.21 cm)
Minimum vertical spacing between shelves: 17 inches (43.18 cm)
Multidock "
Weight: 22.25 lbs. (10.09 kg)
"
Dimensions: "
Length: 37 inches (93.98 cm)
"
Width:
"
"
Without cables 10.75 inches (27.31 cm) With cables 13.25 inches (29.21 cm)
Height: Dock only 8 inches (20.32 cm) Dock with hand-held computers 11.5 inches (29.21 cm)
Minimum vertical spacing between shelves: 17 inches (43.18 cm)
6400 Single and Multidock Installation Instructions 1-5
Page 12
SECTION 1
"
General Information
Connector Pin-Outs 8-Pin Interface Connector
7
5
3
1
8
6
4
2
Figure 1-3 Interface Connector Table 1-1 8-Pin Connector Pin-Outs
1-6
Pin
Signal Name
Function on Dock
I/O from Dock
1
BCLK
Battery Interface Clock
Input
2
DOCKPWR
12 Volt Charge Power
Output
3
GND
Ground
4
BDAT
Battery Interface Data
Input
5
TXD
Transmit Data
Input
6
RXD
Receive Data
Output
7
RTS
Request To Send
Input
8
CTS
Clear To Send
Output
6400 Single and Multidock Installation Instructions
Page 13
SECTION 1
"
General Information
Single Dock 9-Pin Male Serial Port The single dock RS-232 port, available on a DB9 male connector, is generated from the IrDA interface on your hand-held computer.It has no hardware handshake available and has the following signals. 1
2
3
4
5
6
7
8
9
Figure 1-4 Single Dock 9-Pin Male Connector Table 1-2 Single Dock 9-Pin Serial Port Connector Pin-Outs
Pin
Signal Name
Function
Standard Function on PC
I/O on Dock
1
NC
No Connect
Data Carrier Detect (DCD)
2
RXD
Receive Data
Receive Data
Input
3
TXD
Transmit Data
Transmit Data
Output
4
DTR
Forced Low
Data Terminal Ready
Output
5
GND
Ground
Ground
6
DSR
To Set Baud Rate
Data Send Ready
Input
7
RTS
Forced Low
Request To Send
Output
8
CTS
To Set Baud Rate
Clear To Send
Input
9
NC
No Connect
Ring Indicator
Use pin 6 and 8 of this RS-232 connector to set the baud rate of the IrDA controller located inside the single dock. The standard is to have the baud rate set at 9600. Table 1-3 on page 1-8 shows the baud rate for each combination of control lines. 6400 Single and Multidock Installation Instructions 1-7
Page 14
SECTION 1
"
General Information
Table 1-3 Baud Rate Setting
DSR Pin 6
CTS Pin 8
Baud Rate
1
1
9600
1
0
9600
0
1
19.2 K
0
0
115.2 K
Single Dock 25-Pin Male Serial Port Table 1-4 on page 1-9, shows the signals for the single dock RS-232/RS-485 port DB25 male connector. This connector will support the standard 25-pin RS-232 serial cables. The single port supports RS-485 operations when you use cable, Norand part number 226-231-001. This cable will ground the 485 enable line and provide two 9-pin connectors to connect to the standard RS-485 cables, Norand part number 226-103-xxx (xxx indicates length). Your sales team will help you determine the length you need for your installation. Two connectors are provided so that the RS-485 host and a powered RS-485 terminator (NPN: 226-257-001) can be connected, or the network can be continued through to another host computer or dock. For more information about using the powered terminator in your network design work with your Norand sales team.
25
13
14
1
Figure 1-5 Single Dock 25-Pin Male Connector
1-8
6400 Single and Multidock Installation Instructions
Page 15
SECTION 1
"
General Information
Table 1-4 Single Dock 25-Pin Serial Port Connector Pin-Outs
Pin
Signal Name
Function
1
GND
Ground
2
TXD
Transmit Data
3
RXD
Receive Data
4
RTS
Ready To Send
5
CTS
Clear To Send
6
DSR
Data Set Ready
7
GND
Ground
8
DCD
Data Carrier Detect
9
NC
No Connect
10
NC
No Connect
11
485+
RS-485 Positive Side
12
NC
No Connect
13
NC
No Connect
14
NC
No Connect
15
NC
No Connect
16
NC
No Connect
17
NC
No Connect
18
485-
RS-485 Negative Side
19
485 Enable
20
DTR
Data Terminal Ready
21
NC
No Connect
22
NC
No Connect
23
NC
No Connect
24
NC
No Connect
25
NC
No Connect
Comments
Connected to pin 20 DTR
If grounded 485 Enabled Connected to pin 6 DSR
6400 Single and Multidock Installation Instructions 1-9
Page 16
SECTION 1
"
General Information
Multidock 9-Pin Female RS-485 Connector 5
4
3
2
1
9
8
7
6
Figure 1-6 Multidock 9-Pin Female RS-485 Connector Table 1-5 Multidock 9-Pin Connector Pin-Outs
1-10
Pin Signal Name
Function
1
NC
No Connect
2
485+
485 Positive Data Signal
I/O
3
485-
485 Negative Data Signal
I/O
4
NC
No Connect
5
NC
No Connect
6
NC
No Connect
7
NC
No Connect
8
NC
No Connect
9
NC
No Connect
6400 Single and Multidock Installation Instructions
I/O to Dock
Page 17
Section 2 Single and Multidock Installation "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Installation Guidelines The single and multidock can be placed (installed) on a desk, countertop, or mounted onto a structure. If your dock is to be installed on a desk or countertop, then plugging into a power source is about your only consideration for concern. Wall mounting your dock involves a suitable structure to hold the weight of one or several docking units. Wall mounting kits are available that contain the brackets and hardware necessary for this purpose. This instruction booklet contains the instructions for mounting single and multidocks.
Installation Guidelines Single and multidock units are intended to be installed and used in environments that remain at about room temperature opposed to high and low extremes. These docks are specifically not designed for use in these environments: "
Outdoor loading dock, or staging area
"
Walk-in coolers or other refrigerated storage areas
"
Over-heated areas such as incubation room
"
High-humidity environments
"
Confined, unventilated space such as a storage closet
"
Wherever chemical dust, fumes, or corrosives materials are present
Electrical Requirements The single and multidocks contain an autosensing (90-240) voltage power supply that uses the alternating current (ac) power from your 2-1
6400 Single and Multidock Installation Instructions
Page 18
SECTION 2
"
Single and Multidock Installation outlets. The docks come with a six foot universal power cord and therefore must located within that distance of an outlet. The outlets must be grounded (three-prong) and with sufficient current to carry the load for the number of docks per circuit breaker. If you are uploading and downloading data with the host computer you will need to have data jacks close by. You will also need to have communication cables for connecting the docks to the jacks. The connectors are identified in this booklet but cables are not provided in the installation kit.
6400 Single and Multidock Installation Instructions
2-2
Page 19
SECTION 2
"
Single and Multidock Installation
Electrical and Communication Connections Figures 2-1 and 2-2 show the connectors for the single and multidocks.
3 1 2
Back view 1. RS-232 or RS-485 serial port 2. RS-232 serial port 3. AC connector
Figure 2-1 Single Dock Connectors
1
2
Back view 1. RS-485 connectors 2. AC connector
Figure 2-2 Multi Dock Connectors
2-3
6400 Single and Multidock Installation Instructions
Page 20
SECTION 2
"
Single and Multidock Installation
Dock Installation The single dock is small and fairly lightweight, you can attach the dock the brackets first, and then install the complete assembly to the wall. Or, you can install the mounting brackets on the wall before attaching the single dock. Installing the mounting brackets first is probably the preferred method and therefore the instructions for that follow next.
Mounting Structure You can install the docks on most structures made of wood, concrete, or cinder block. Use anchors that will support the weight and are designed for the type of wall you will be using. Some anchor selection guidelines are: "
"
Concrete structures use metal expansion anchors. Plastic anchors or dowels will not hold. Cinder block walls, use 1/4 inch or larger toggle bolts into the hollow portions of the blocks. Expansion anchors or dowels pull loose over time.
6400 Single and Multidock Installation Instructions
2-4