Page 23

Section 2

Using Terminal Emulation Applications "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

Annunciators The terminal’s display reserves a location for annunciators (icons) that help you monitor RF and network communications, or alert you of a condition that requires action. Following are 5250 TE annunciators.

X

Input inhibited The keyboard has accepted enough information for the defined input field. The “key-ahead” feature stores keystrokes after the “input inhibited” annunciator appears. These are saved for the next field. Insert mode The keyboard inserts characters instead of overwriting them.

M

Message waiting The host has a message waiting for the operator.

For information about annunciators that indicate battery condition and general operational status, refer to the terminal’s user manual.

Auto-Advancing through Fields You can set up your Trakker Antares R terminal to auto-advance through the fields on a 5250 TE screen. When you scan data into a field on a 5250 TE screen, a Field Exit command clears the rest of the field, advances to the next field, and triggers an auto-enter field to send an ENTER to the application and submit the data. You can just scan data and never touch the keyboard. To set this up, you need to disable Auto Tab Scan in the TE configuration menus, and set the Postamble command to the 5250 Field Exit code. There are three ways to configure the Postamble command: Use the TRAKKER Antares 2400 Menu System. Download Postamble command from the DCS 300 to one or more terminals. " Download the Postamble command from a host using either the TCP/IP direct connect protocol or UDP Plus protocol. The first two configuration methods are listed in this section. The third method involves creating an application and then downloading the application to the terminals. For help creating the application, refer to your terminal’s user manual. " "

The 5250 Field Exit code is a character in the extended ASCII character set. The terminal supports the full and extended ASCII character sets. For a list of the full and extended ASCII characters, refer to your terminal’s user manual. TE 2000t 5250 Terminal Emulation Programmer’s Guide

2-1

Page 24

Using Terminal Emulation Applications

" NOTE:

SECTION 2

You can also configure the postamble by scanning the Postamble command. However, you cannot scan in extended ASCII characters like the 5250 Field Exit code.

To disable Auto Tab Scan: 1. Configure the Auto Tab Scan setting to Disable. For help, see Section 4, “Using the Terminal Emulation Configuration Menus.” With the Auto Tab Scan feature disabled, the terminal functions as if the field has a mandatory field exit turned on (an AS/400 activated feature known as Check FE). As a result, legacy AS/400 applications do not have to be modified to turn this field on properly for bar code support. The default is Auto Tab Scan disabled.

2. Save your new TE configuration. To add Field Exit to the postamble via TRAKKER Antares 2400 Menu System: 1. Access the TRAKKER Antares 2400 Menu System. For help, refer to your terminal’s user manual. 2. From the Main Menu, choose Configuration Menu. 3. From the Configuration Menu, choose Terminal Menu. 4. From the Terminal Menu, choose Preamble/Postamble. 5. Move the cursor to the postamble field. 6. Type \x9A for the literal Field Exit code. 7. Press ; or choose OK to save your changes and exit the screen. 8. Exit the TRAKKER Antares 2400 Menu System and save your new configuration to flash memory. For help, refer to your terminal’s user manual. To download Field Exit as a postamble from the DCS 300: Configure the postamble to the Field Exit’s literal value using the download server on the DCS 300. Use the download server on the DCS 300 to configure one or more terminals in the network. 1. In the download server on the DCS 300, select the terminal or group to receive the Postamble (AE) configuration command. For help on configuring a group of terminals, refer to the DCS 300 System Manual. You can continue running the 5250 TE application on the terminal while configuring a terminal from the DCS 300. 2. Choose the option to enter a command. 3. Type the string $+AE and then enter the ASCII code 154 by holding down the Alt key while typing 154 on the numeric keypad. You should see an Ü to represent the literal Field Exit code in the edit box, which now shows $+AEÜ this command and value: 4. Download the commands to change the runtime configuration of the terminals selected. The changes are saved in RAM, but not in flash memory. 5. To save the configuration change in flash memory, download this command: .+1 You can also use the TRAKKER Antares 2400 Menu System to save the configuration in flash memory. Refer to the terminal’s user manual. You can set the postamble or preamble to any character from the extended ASCII character set using these instructions. Type the literal ASCII value in Step 3 instead of the Field Exit code. To set the preamble, use the syntax $+AD instead of $+AE. For more information about screen modes, see Section 4, “Using the Terminal Emulation Configuration Menus.” 2-2

TE 2000t 5250 Terminal Emulation Programmer’s Guide

Page 25

SECTION 2

Using Terminal Emulation Applications

Special Function Keys Special function keys are: " Attention Identification (AID) keys Signal keys " Cursor movement keys " Special control keys " Field Exit key " Special host keys To enter a special function key: Press the keys listed in the section for the terminal. Or, scan the bar code in Appendix A. "

The following pages describe the special functions keys. For complete descriptions, refer to the appropriate IBM 5250 reference manual.

AID-Generating Keys AID-generating keys generate AID codes that go in the display data stream to the host system. They alert the host system that the DCS 300 or controller requires some action. The terminal emulates all of the AID-generating keys on a 5291 Display Station. The following lists the keys. Clear The system environment determines the results of this key. If the terminal is in session, [CLEAR] issues the AID code hex BD, which requests the host system issue a Clear Unit command to the terminal to clear the display. If not in session, [CLEAR] clears the entire display regeneration buffer. Enter/Rec Adv Enters information. F1–F24 User-defined command functions. Refer to your application’s user manual for detail on the functions. Help (nonerror state) Issues a hex F3 AID byte to the host system. Print Tells the controller that the operator wants to print the contents of the present display. Issues hex F6 to the host system. Record Backspace (Home) When pressed with the cursor in the home position, a record backspace is requested. The AID code hex F8 and cursor address are sent to the host system. Roll Up and Roll Down Roll display up or down one page. Roll Up issues AID code hex F5. Roll Down issues AID code hex F4. For more information on the Roll keys, see next page.

TE 2000t 5250 Terminal Emulation Programmer’s Guide

2-3

Page 26

Using Terminal Emulation Applications

SECTION 2

Roll Keys Roll Up and Roll Down are AID keys the terminal sends to the host to request and display additional screens. The host transmits a new screen in response to this command. The new screens allow you to view data either above or below what appears on the current screen. 5250 Terminals support the Roll command (hex 23) received from a host application. Using this command, a host application can roll an area of the screen up or down. The direction of the roll and number of lines to roll are specified in the command. Do not confuse the Roll Up and Roll Down AID keys with the Roll command. The Roll keys cause the host to send down additional screens when you are at a Roll screen. A Roll screen typically has text in the lower right-hand corner of the screen indicating that there are additional screens to view. Note the following: A Roll command received from a host application moves the screen, but not the window/viewport. The screen scrolls through the window/viewport when you roll up or down, but the window/viewport remains stationary. " Paging keys (window/viewport page up, window/viewport page down, window/viewport page right, window/viewport page left) move the viewport within one screen. They do not move the screen itself. For help with the Roll command, see Section 6, “Display Data Stream.” "

Cursor Keys You can manually move the terminal’s window/viewport by using the cursor keys and paging keys. For more information about the window/viewport, refer to the terminal’s user manual.

Field Exit Key Field Exit exits an input field and moves the cursor to the beginning of the next input field. If you press this key while the cursor is between characters, then all characters to the right of the cursor are erased. " NOTE:

On Trakker Antares terminals, you can set the Postamble or Preamble command to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing through Fields” earlier in this section.

Signal Keys Signal keys cause a Signal command to go from the controller to the host system. The following describes the signal keys. Attn The operator presses this key to alert the host system the function request (such as [ENTER]) is not honored. Attn is valid when the keyboard is locked or unlocked. It does not change the keyboard state or the cursor location. Help (from error state) The operator uses this key to request that the host system send data about the error to the display. 2-4

TE 2000t 5250 Terminal Emulation Programmer’s Guide

Page 27

SECTION 2

Using Terminal Emulation Applications

Special Control Keys Use special control keys to change operator-generated information in the display. The keys do not work when the keyboard is locked. Del Deletes the character in the position where the cursor was located. All remaining characters in the field shift to the left to fill the column. Erase Input Clears all fields to nulls, and cursor moves to the first input position on screen. This command does not erase protected fields. If you press this key when the screen shows only protected fields, the cursor returns to the home position. Error Reset Restores the original data on the error line of the display and resets the state. Hex Enters hexadecimal codes from the keyboard to generate any EBCDIC characters needed for input or display. Home Moves the cursor to the position specified by the insert cursor (IC) address. Insert Sets or turns off the insert mode for the input field the operator has the cursor in. The operator must reset the insert state before exiting it, by either pressing [RESET] or [INSERT] again. Shift Lock Puts the keyboard into shift lock mode.

Special Host Key The special 5250 host key is System Request. Sys Req Data on the error line is saved, the error line is cleared, a column separator and underscore field attribute are supplied to column 1 of the error line, and the cursor is located under column 2 to begin polling keystrokes.

TE 2000t 5250 Terminal Emulation Programmer’s Guide

2-5

Page 28

Using Terminal Emulation Applications

SECTION 2

5250 Additional Functions The following lists additional operations you can perform on your terminal. ¢ (cent sign) Enters a cent sign. (New Line) Moves the cursor to the first unprotected character position of the first line in the screen. If the entire screen is a protected field, the cursor returns to the home position. ™ (Not symbol) Enters a Not symbol. Back Tab Moves the cursor back to the most recent first field position. If the cursor is in the middle of a field, it moves it to the first position of the same field. If the cursor is at the first position of a field, it moves it to the first position of the preceding input field. Dup (duplicate enabled fields only) Controller repeats hex “1C” from the cursor position to the end of the field. This shows in the display as an overstruck asterisk. Field– For numeric fields, makes the input a negative number. Field+ Advances cursor to the next input field. For numeric fields, makes the input a positive number. Field Mark This is valid within any unprotected entry input field in which the Dup or Field Mark key is allowed (FFW bit 3 set to on). The Field Mark character (X‘1E’) is displayed as an overscore on IBM 5251 Display Stations and as a space on all other supported workstations. If an operator presses the Field Mark key in an entry field that does not allow the Dup or Field Mark key, operator error 0019 is posted. The Field Mark code point is allowed in an outbound data stream. Forward Tab Moves the cursor to the first position in the next input field. To enter an operation: Press the keys listed in the section for the terminal. Or, scan the bar code in Appendix A.

System Messages The terminal’s display reserves a line for status information. The status line can display system (nonlocal) information such as a message waiting from the host computer, help messages in response to the [Help] key, or the system request state of the terminal. System codes can also appear on the status line. System messages and codes are described in Section 6, “Display Data Stream.”

2-6