Page 219

SECTION 7

Extended Commands

UPC Use the UPC command to select the combinations of characters listed in Table 7-14. 6400 Computers do not support UPC-E Number System 1. Note that “b” indicates a 1-byte space. Table 7-14 UPC Bar Code Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Options Character

UPC-E # System 1

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 b

Expand UPC-E to UPC-A

UPC-E # System 0

Add-ons

UPC-A x x x x x x x x x x x x x x x x

Disables all. x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x No change from current setting x

EAN Algorithms Use EAN Algorithms to select combinations of EAN options (Table 7-15). Note that “b” indicates a 1-byte space. Table 7-15 EAN Algorithms (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 12 Character

Description

0 1 2 3 b

EAN disabled EAN with Add-ons enabled EAN enabled EAN and EAN with Add-ons enabled No change from current setting

TE 2000t 5250 Terminal Emulation Programmer’s Guide

7-17

Page 220

SECTION 7

Extended Commands

Code 39 Code 39 (Table 7-16) sets the scanner to read simple Code 39 bar codes that do not include extended or encoded sequences. Note that “b” indicates a 1-byte space. Table 7-16 Code 39 Algorithms Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 13 Character

Description

0 1 2 3 b

Code 39 disabled Encoded Code 39 enabled Extended Code 39 enabled Code 39 enabled No change from current setting

Extended Code 39 is a superset of Code 39 and scans all regular Code 39 bar codes. You cannot select both Code 39 and Extended Code 39. Encoded Code 39 combines key presses with normal bar code data. Appendix A contains Encoded Code 39 sequences.

Plessey If the Plessey bar code scanning algorithm is enabled, set its check digits (Table 7-17) according to your requirements. Refer to the manufacturer ’s bar code specifications for more information on check digits. 6400 Computers do not support Plessey alpha characters. Note that “b” indicates a 1-byte space. Table 7-17 Plessey Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 14

7-18

Character

Description

0 1 b

Plessey disabled Plessey enabled No change from current setting

TE 2000t 5250 Terminal Emulation Programmer’s Guide

Page 221

SECTION 7

Extended Commands

The dots in Table 7-18 indicate the Plessey check digits the characters support. Note that “b” indicates a 1-byte space. Table 7-18 Plessey Check Digit Characters Line 1, Column 15 Character 0 1 2 3 4 5 6 7 8 9 A B C D E F b

Keep 2nd Digit Check

Do Not Validate 1st Check Digit

Keep 1st Check Digit

Mod 10 1st Check Digit

Mod 11 1st Check Digit x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x No change from current setting x x x x x

Codabar The Codabar options (Codabar and ABC Codabar) are mutually exclusive coding algorithms and cannot be selected at the same time. Note that “b” indicates a 1-byte space. Table 7-19 Codabar Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 16 Character

Description

0 1 2 b

Codabar disabled Codabar enabled ABC Codabar enabled No change from current setting

TE 2000t 5250 Terminal Emulation Programmer’s Guide

7-19

Page 222

SECTION 7

Extended Commands

Code 11 Note that “b” indicates a 1-byte space. Table 7-20 Code 11 Characters (59XX, 17XX, 11XX Terminals) Line 1, Column 17 Character

Description

0 1 b

Code 11 disabled Code 11 enabled No change from current setting

Code 93 Code 93 and Code 128 options can be enabled. Note that “b” indicates a 1-byte space. Table 7-21 Code 93 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 18 Character

Description

0 1 b

Code 93 disabled Code 93 enabled No change from current setting

Code 128 Note that “b” indicates a 1-byte space. Table 7-22 Code 128 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 19

7-20

Character

Description

0 1 b

Code 128 disabled Code 128 enabled No change from current setting

TE 2000t 5250 Terminal Emulation Programmer’s Guide

Page 223

SECTION 7

Extended Commands

Straight or Computer Identics 2of5 If the Straight or Computer Identics bar code is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements. Note that “b” indicates a 1-byte space. Refer to the manufacturer’s bar code specifications for more information. Table 7-23 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 20--28 Column Character 20 23--24 25--26 27--28

0=Straight and Computer Identics 2 of 5 disabled; 1=Computer Identics 2 of 5 enabled; 2=Straight 2 of 5 enabled; b=No change from current setting XX=Minimum length Straight or Computer Identics 2 of 5; bb=No change from current setting XX=First fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting XX=Second fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting

Interleaved 2 of 5 If Interleaved 2 of 5 is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements. Note that “b” indicates a 1-byte space. Refer to the manufacturer ’s bar code specifications for more information. Table 7-24 Interleaved 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 29--37 Column Character 29 30--31 32--33 34--35 36--37

0=Interleaved 2 of 5 disabled; 1=Interleaved 2 of 5 enabled; b=No change from current setting XX=Maximum length Interleaved 2 of 5; bb=No change from current setting XX=Minimum length Interleaved 2 of 5; bb=No change from current setting XX=1st fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting XX=2nd fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting

Return Codes for Scan Bar Code The Scan Bar Code Parameters return code is the status sent to the host computer; the code indicates if the extended command was successful. The terminal returns data and the extended command’s status to the host computer in the \\X<CR> format where “X” is the return code listed in the following chart. The terminal simulates the [ENTER] key to return a value to the host computer. If a hexadecimal number is entered wrong, the return code defaults to “0.” Code

Description

0 1

Good status, transaction complete Bad status, transaction incomplete

TE 2000t 5250 Terminal Emulation Programmer’s Guide

7-21

Page 224

SECTION 7

Extended Commands

Example of Scan Bar Code Parameters The following example and chart show data for Scan Bar Code Parameters. Note that “b” indicates a 1-byte space. Column 1

Column 11

Column 23

Column 36 b#S07F32012211120012080108080bbbbbbbb Column Character 1 2 3 4 5 6 7--8 9--10 11 12 13 14 15 16 17 18 19 20 21--22 23--24 25--26 27--28 29 30--31 32--33 34--35 36--37

7-22 b # S 0 7 F 32 01 2 2 1 1 1 2 0 0 1 2 08 01 08 08 0 bb bb bb bb

Description This column typically contains a space Extended command Scan Bar Code Parameter command No Control Byte 1 options are returned [ENTER] key terminates all scans, 12-volt laser is enabled, Mod 10 Check Digit Barcode type is returned and concatenated Maximum length is 32 characters Minimum length is 1 character Decode UPC System 0 EAN is enabled Encoded code 39 is enabled Plessey is enabled Mod 10 first digit is checked ABC Codabar is enabled Code 11 is disabled Code 93 is disabled Code 128 is enabled Straight 2 of 5 is enabled Straight 2 of 5 maximum length is 8 Straight 2 of 5 minimum length is 1 Straight 2 of 5 1st fixed length is 8 Straight 2 of 5 2nd fixed length is 8 Interleaved 2 of 5 is disabled No change from current setting No change from current setting No change from current setting No change from current setting

TE 2000t 5250 Terminal Emulation Programmer’s Guide