The text of a manual · part 23 of 28
TE 2000 3270 Terminal Emulation Programmer's Guide: Section 7: Extended Commands, pages 191 to 196
Pages 191 to 196 of 240, from TE 2000 3270 Terminal Emulation Programmer's Guide
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 191
Extended Commands
SECTION 7
EAN Algorithms Use EAN Algorithms to select combinations of EAN options (Table 7-15). Note that “b” indicates a 1-byte space. Table 7-15 EAN Algorithms (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 12 Character Description EAN disabled EAN with Add-ons enabled EAN enabled EAN and EAN with Add-ons enabled No change from current setting
0 1 2 3 b
Code 39 Code 39 (Table 7-16) sets the scanner to read simple Code 39 bar codes that do not include extended or encoded sequences. Note that “b” indicates a 1-byte space. Extended Code 39 is a superset of Code 39 and scans all regular Code 39 bar codes. You cannot select both Code 39 and Extended Code 39. Encoded Code 39 combines key presses with normal bar code data. Appendix A contains Encoded Code 39 sequences. Table 7-16 Code 39 Algorithms Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 13 Character Description Code 39 disabled Encoded Code 39 enabled Extended Code 39 enabled Code 39 enabled No change from current setting
0 1 2 3 b
Plessey " NOTE:
The 6400 Computer does not support Plessey alpha characters.
If the Plessey bar code scanning algorithm is enabled, set its check digits (Table 7-17) according to your requirements. Refer to the manufacturer ’s bar code specifications for more information on check digits. Note that “b” indicates a 1-byte space. Table 7-17 Plessey Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 14 Character Description 0 1 b
Plessey disabled Plessey enabled No change from current setting TE 2000t 3270 Terminal Emulation Programmer’s Guide
7-17
Page 192
Extended Commands
SECTION 7
The dots in Table 7-18 indicate the Plessey check digits the characters support. Note that “b” indicates a 1-byte space. Table 7-18 Plessey Check Digit Characters Line 1, Column 15 Do Not Validate Keep 1st Mod 10 1st Keep 2nd Character Digit Check 1st Check Digit Check Digit Check Digit 0 x 1 x 2 x x 3 x 4 x x 5 x x 6 x x x 7 x 8 x x 9 x x A x x x B x x C x x x D x x x E x x x x F b No change from current setting
Mod 11 1st Check Digit x x x x x x x x
Codabar The Codabar options (Codabar and ABC Codabar) are mutually exclusive coding algorithms and cannot be selected at the same time. Note that “b” indicates a 1-byte space. Table 7-19 Codabar Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 16 Description Character 0 1 2 b
7-18
Codabar disabled Codabar enabled ABC Codabar enabled No change from current setting
TE 2000t 3270 Terminal Emulation Programmer’s Guide
Page 193
Extended Commands
SECTION 7
Code 11 Note that “b” indicates a 1-byte space. Table 7-20 Code 11 Characters (59XX, 17XX, 11XX Terminals) Line 1, Column 17 Character Description Code 11 disabled Code 11 enabled No change from current setting
0 1 b
Code 93 Code 93 and Code 128 options can be enabled. Note that “b” indicates a 1-byte space. Table 7-21 Code 93 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 18 Character Description 0 1 b
Code 93 disabled Code 93 enabled No change from current setting
Code 128 Note that “b” indicates a 1-byte space. Table 7-22 Code 128 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Column 19 Character Description 0 1 b
Code 128 disabled Code 128 enabled No change from current setting
TE 2000t 3270 Terminal Emulation Programmer’s Guide
7-19
Page 194
Extended Commands
SECTION 7
Straight or Computer Identics 2 of 5 If the Straight or Computer Identics bar code is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements (Table 7-23). Note that “b” indicates a 1-byte space. Refer to the manufacturer ’s bar code specifications for more information. Table 7-23 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 20--28 Column Character 20 21--22 23--24 25--26 27--28
0=Straight and Computer Identics 2 of 5 disabled; 1=Computer Identics 2 of 5 enabled; 2=Straight 2 of 5 enabled; b=No change from current setting XX=Maximum length Straight or Computer Identics 2 of 5; bb=No change from current setting XX=Minimum length Straight or Computer Identics 2 of 5; bb=No change from current setting. XX=First fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting XX=Second fixed bar code length for Straight or Computer Identics 2 of 5; bb=No change from current setting
Interleaved 2 of 5 If Interleaved 2 of 5 is enabled, select the maximum and minimum lengths and the 1st and 2nd fixed bar code lengths according to your requirements (Table 7-24). Note that “b” indicates a 1-byte space. Refer to the manufacturer ’s bar code specifications for more information. Table 7-24 Interleaved 2 of 5 Characters (6400, 5055, 59XX, 17XX, 11XX Terminals) Line 1, Columns 29--37 Column Character 29 30--31 32--33 34--35 36--37
0=Interleaved 2 of 5 disabled; 1=Interleaved 2 of 5 enabled; b=No change from current setting XX=Maximum length Interleaved 2 of 5; bb=No change from current setting XX=Minimum length Interleaved 2 of 5; bb=No change from current setting XX=First fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting XX=Second fixed length for Interleaved 2 of 5 Bar Code; bb=No change from current setting
Return Codes for Scan Bar Code The Scan Bar Code Parameters return code is the status sent to the host computer; the code indicates if the extended command was successful. The terminal returns data and the extended command’s status to the host computer in the \\X<CR> format where “X” is the return code listed in the following chart. Code 0 1
Description Good status, transaction complete Bad status, transaction incomplete
The terminal simulates the [ENTER] key to return a value to the host computer. If a hexadecimal number is entered wrong, the return code defaults to “0.” 7-20
TE 2000t 3270 Terminal Emulation Programmer’s Guide
Page 195
Extended Commands
SECTION 7
Example of Scan Bar Code Parameters The following example and chart show data for Scan Bar Code Parameters. Note that “b” indicates a 1-byte space. Column 1
Column 11
Column 23
Column 36 b#S07F32012211120012080108080bbbbbbbb Column 1 2 3 4 5 6 7--8 9--10 11 12 13 14 15 16 17 18 19 20 21--22 23--24 25--26 27--28 29 30--31 32--33 34--35 36--37
Character b # S 0 7 F 32 01 2 2 1 1 1 2 0 0 1 2 08 01 08 08 0 bb bb bb bb
Description This column typically contains a space Extended command Scan Bar Code Parameter command No Control Byte 1 options are returned [ENTER] key terminates all scans, 12-volt laser is enabled, Mod 10 Check Digit Bar code type is returned and concatenated Maximum length is 32 characters Minimum length is 1 character Decode UPC System 0 EAN is enabled Encoded code 39 is enabled Plessey is enabled Mod 10 first digit is checked ABC Codabar is enabled Code 11 is disabled Code 93 is disabled Code 128 is enabled Straight 2 of 5 is enabled Straight 2 of 5 maximum length is 8 Straight 2 of 5 minimum length is 1 Straight 2 of 5 1st fixed length is 8 Straight 2 of 5 2nd fixed length is 8 Interleaved 2 of 5 is disabled No change from current setting No change from current setting No change from current setting No change from current setting
TE 2000t 3270 Terminal Emulation Programmer’s Guide
7-21
Page 196
Extended Commands
7-22
TE 2000t 3270 Terminal Emulation Programmer’s Guide
SECTION 7