Page 28

User Reference

SECTION 3

If the program can not be found or is prevented from executing in any way, the utility will return to the main menu without executing the program. No error or warning will be generated in this event.

Date/Time The Date/Time screen allows you to set the local system date and time. You may set the date and time in a variety of ways: "

Highlight a field and press the up or down key

"

Enter a new value from the numeric keyboard.

"

Press the arrow icons next to the date or time edit boxes to bring up additional controls to enter the new values.

Date 11/3/00

B

Time 3:39:54 PM

Y B

Time Zone:

B

Auto Daylight Savings Cancel

OK

Figure 3-6 Date/Time Screen 3-10

Windows 95 and Windows CE Configuration Utilities Reference Manual

Page 29

User Reference

SECTION 3

Date This field allows you to set the current date.

Time This field allows you to set the current local time.

OK

The time will be changed when OK is pressed and the utility will return to the Main Menu.

Cancel

Pressing Cancel will return to the main menu without setting the time.

Communicate This screen allows you to select the most common TCOM parameters for an NRINet TCOM session. Select either the Dial--Up Networking or the Wired Network radio buttons. The Dial--Up Networking Advanced button allows enabling Prefix and Number entry fields only if you select the Dial-Up Networking radio button. " The Wired Network Advanced button is only allowed when Wired Network radio button is selected The ’Manually configure the client settings’ Advanced button is only active if the Manually configure the client settings radio check box is selected. "

Windows 95 and Windows CE Configuration Utilities Reference Manual

3-11

Page 30

User Reference

SECTION 3

Communications Setup Dial-Up Advanced Networking Prefix:

Edit

ABC

Number: Edit

ABC

Advanced Wired Network Manually Advanced configure the client settings (no DHCP) Cancel

Start

OK

Figure 3-7 Communicate Screen

Dial-Up Networking Select the radio button to perform TCOM using a modem and phone lines. This option enables: "

"

The Dial--Up Networking Advanced button which allows setting more advanced features of Dial-Up communications. It also enables The Prefix and Number fields described below.

This also deselects the Wired Network option. Refer to the Dial--Up Networking screen below for additional settings.

Wired Network Select this for communications over a wired LAN. 3-12

Windows 95 and Windows CE Configuration Utilities Reference Manual

Page 31

User Reference

SECTION 3

This option enables the Wired Network Advanced button which allows the setting of more advanced features of Wired communications. It will also deselect the Dial-Up Networking option. Refer to the Wired Network screen below for additional settings.

Manually configure the client settings (no DHCP) Select this when DHCP is not available or not desired. If this is selected then the settings on the Client screen will be used. Press the Advanced button to set or review the Client screen settings.

Cancel

Pressing this button returns you to the Main Menu screen without saving the changes to this screen.

OK

Pressing this button returns you to the Main Menu Screen saving the changes to this screen.

Start

Press the Start button to begin a TCOM session after saving the changes selected on this screen. Once the TCOM session is completed, the HHC unit will reboot, or return to the Banner screen, depending on the –b command line flag. Refer back to Table 2-1 Command Line flags earlier in this section for additional details. If an error occurs during the TCOM session, a message box with the error number will pop up. After saying OK to this message box, you will remain on the TCOM screen. See Section 3 on TCOM Codes. Windows 95 and Windows CE Configuration Utilities Reference Manual

3-13

Page 32

User Reference

SECTION 3

Dial-Up Networking This screen lets you set more advanced communications options needed when using Dial--Up Networking.

Dial-up Networking Username: Edit Password: Edit NT Domain: Edit IP Address: Edit Port: Edit I/O Timeout: Edit Modem:

ABC ABC ABC ABC ABC ABC B

Cancel

OK

Figure 3-8 Dial-up Networking Screen

Username The Username field should contain the Dial--Up Networking Username for the PPP server. This may not be the same Username as specified on the 6920.

Password The Password field should contain the Dial--Up Networking Password for the PPP server. This may not be the same Password as specified on the 6920.

NT Domain Provides the dial--up server with a Windows NT Domain name. 3-14

Windows 95 and Windows CE Configuration Utilities Reference Manual

Page 33

User Reference

SECTION 3

IP Address This is the IP address or host name of the 6920 host that you are connecting to. This same setting may be found on the Wired Network Advanced screen.

Port TCP/IP port number, or the service entry name in the services file that the 6920 server is configured on. This same setting may be found on the Wired Network Advanced screen.

I/O Timeout If there is a break in communications for a period of the number of seconds specified here, the TCOM session will end and an error reported. This same setting may be found on the Wired Network Advanced screen.

Modem This is the modem that the TCOM session uses. Pressing the arrow on the right of this field brings up a list of modems available.

Cancel

Pressing this button returns you to the Communications screen without saving your changes to this screen.

OK

Pressing this button returns you to the Communications screen after saving your changes to this screen. Windows 95 and Windows CE Configuration Utilities Reference Manual

3-15

Page 34

User Reference

SECTION 3

Wired Network This screen allows advanced settings for communicating over a wired network.

Wired Network IP Address: 6920SER

ABC ABC ABC

Port: 44965 I/O Timeout: 45 n

Load NDIS driver Line Speed 115,200 bps 460,800 bps

Cancel

OK

Figure 3-9 Wired Network Screen

IP Address The IP address or host name of the 6920 host that you are connecting to. This same setting may be found on the Dial-Up Networking Advanced screen.

Port TCP/IP port number or the service entry name in the services file that the 6920 server is configured on. This same setting may be found on the Dial-Up Networking Advanced screen. 3-16

Windows 95 and Windows CE Configuration Utilities Reference Manual

Page 35

User Reference

SECTION 3

I/O Timeout If there is a break in communications for a specified number of seconds, the TCOM session ends and an error reported. This same setting may be found on the Dial--Up Networking Advanced screen.

Load NDIS driver When connecting using a LAN, checking this box causes the NDIS driver to be loaded before a socket is opened. If the HHC is already connected and operating on a LAN, then the user should remove the check. Default is checked.

Line Speed (115,200 bps,460,800 bps) This setting is available only on the 6110 HHC. These two radio buttons control the line speed of the RS-485 connection to the 6710. 115,200 bps is currently the only valid choice.

Cancel

Pressing this button returns you to the Communications screen without saving your changes to this screen.

OK

Pressing this button returns you to the Communications screen after saving your changes to this screen.

Windows 95 and Windows CE Configuration Utilities Reference Manual

3-17

Page 36

User Reference

SECTION 3

Client This screen contains settings needed if you are not using DHCP for the TCOM session.

Client Setup IP Address: Edit Subnet Mask: Edit Default Gateway: Edit Domain: Edit DNS Server: Edit Cancel

ABC ABC ABC ABC ABC OK

Figure 3-10 Client Setup Screen

IP Address The IP Address that the HHC uses for the TCOM Session.

Subnet Mask The Subnet Mask that the HHC uses for the TCOM Session.

Default Gateway The Default Gateway that the HHC uses for the TCOM session. 3-18

Windows 95 and Windows CE Configuration Utilities Reference Manual