Page 21

SECTION 2

Operation

Power Status LED

Power Status: Blinking Red indicates low battery status Continuous Red indicates charging in process Continuous Green indicates charging complete Blinking Green indicates computer is in standby mode Off indicates normal operation

Figure 2-2 Power Status LED

600 Series Industrial Mobile Computer User’s Guide

2-3

Page 22

Operation

SECTION 2

Installing CompactFlash Card 1. Gently apply pressure as you guide the card downward into the card slot. 2. Press at the top end of the card to “set” the bottom end of the card in the pin connector at the bottom of the card slot. 3. Gradually relax the pressure but still gently press the card into place until it is fully seated down in the card slot. CompactFlash card

Wide channel

Figure 2-3 Accessing the CompactFlash Card Slot 2-4

600 Series Industrial Mobile Computer User’s Guide

Page 23

SECTION 2

Operation

Removing the CompactFlash Card Use the tip of your stylus, inserted in the slot and under the edge on the CompactFlash card, to slide the card out enough to get ahold of it and pull straight out on the card slot. Intermec also offers self-adhesive pull tabs (p/n 806-896-001) to help with removal of CF cards.

1

2

Stylus slot

3

Figure 2-4 Removing CompactFlash Card 600 Series Industrial Mobile Computer User’s Guide

2-5

Page 24

Operation

SECTION 2

Booting Your Computer For DOS Applications 1. Apply power by pressing the [I/O] (Resume/Suspend) key or pressing the reset keys ([Gold], [Esc], [0]) simultaneously and holding for three seconds. The Power Status LED will light. 2. The default load on the card displays these choices: 1. NorandR Utilities 2. DOS Command Prompt. Making this choice puts you to the DOS prompt 600 C:\>. 3. If you do not make a choice within 10 seconds, your 600 Series computer automatically boots to the NorandR Utilities. From the Utilities Programs, assuming you have the appropriate host software and hardware, you can setup the communication options and also download your application.

For Windows CE Applications The following steps outline the initial boot and Windows CE load on the 600 Series Computer. 1. The AT BIOS loads the boot sector from the IDE drive. 2. After NK.BIN (Windows CE memory image) is loaded and executed, Windows CE is in control of the system. From this point, only Windows CE functions are accessible to application developers for the 602 Computer. 3. TASKMAN.EXE (the Windows CE shell program) is executed by Windows CE. The first time CE is executed, “Task Manager” performs pen calibration and writes the calibration results to the registry. The registry is then flushed to persistent storage. 2-6

600 Series Industrial Mobile Computer User’s Guide

Page 25

SECTION 2

Operation

“Task Manager,” then searches for the “\Storage Card\Wince\WCESTART.INI” file. If the file is found, the contents of the file are parsed for any user application to launch and execute. If no application is found, “Task Manager” allows manual browsing of the files system and execution of programs.

Installing Windows CE Components This section outlines the Windows CE release installation for the 600 Series Computer. The installation includes a demo application. Reflashing the 600 Series Computer installs the most current System Management Interface (SMI BIOS) for the 600 Series Computer and erases the current registry for Windows CE that is stored in flash memory. Erasing the registry allows the system to use registry changes incorporated in the new Windows CE release. " NOTE:

Upgrading flash erases the registry and destroys previous settings.

Perform the following steps: 1. Copy 600FLSH.BIN to computer or put on external card. 2. Start up CE, then select Start, then Settings, then Control Panel. 3. Select the icon for the Intermect Utilities. 4. Select the BIOS UPGRADE tab then press the button [...] to bring up the standard browse window. 5. Double tap on 600FLSH.BIN 6. Press the UPGRADE button to start the BIOS Upgrade. You might be prompted to charge your unit first. Highly recommended to begin with a fully charged battery. 600 Series Industrial Mobile Computer User’s Guide

2-7

Page 26

Operation

SECTION 2

7. Reset your computer when completed with the upgrade.

Running Windows CE and the Demo Application Do the following to run the demo application using the Windows CE operating system: 1. Simultaneously press and hold the [GOLD], and [Esc], and [0] keys for at least 3 seconds to reset the 600 Series Computer. 2. Calibrate the touch screen. You may have to calibrate the screen several times until the calibration applet detects a “good” calibration within its tolerance limits. After finishing calibration, the Windows CE desktop will appear with the “Task Manager” application up and running. 3. The demo application starts from “Task Manager” with sample menus for several NMSD base applications: Invoice, Service, and Pickup and Delivery. Menu buttons for Print and Charge Card utilities are available for demo, but are not functional.

For Windows 95 Applications 1. Apply power by pressing the I/O (Resume/Suspend) key or pressing the reset keys (gold, esc., zero) and holding for three seconds simultaneously. The Power Status LED will light. Your hand-held computer begins booting Windows 95. This will take about one minute. 2. Using the stylus, tap in the User Information and tap Next. 2-8

600 Series Industrial Mobile Computer User’s Guide

Page 27

SECTION 2

Operation

3. Windows prompts you to accept the license agreement. Either Tab over, or tap on the I accept the agreement choice and then Next. 4. Key in the WIN 95 product ID number from the Certificate of Authenticity document. 5. The Certificate of Authenticity number comes with your Windows 95 card. Tap on End or press ENTER. 6. Windows may prompt you to update the clock. Tap in the correct time and date and press ENTER. 7. You will probably be asked to enter your username and password. 8. When the Pen Alignment Program comes up, tap on each of the four crosshairs three times. You have 30 seconds to complete the series of three taps (plenty of time!) in each corner. " NOTE:

Pen Alignment is how close to the arrow on the display that you must place your stylus to make the entry or selection.

9. At the Finetune Calibration screen, either tap Save or make the adjustments you want.

Panning Panning is moving around within the display area to view data. The program or application on your hand-held computer was designed on a full size pc display area. To see all that data you must move around on that larger area with your smaller display. Remember these suggestions. First, the cursor will return to the upper left-corner of the display. Second, to keep from getting lost, put your stylus in the middle of the display area and drag it to the right, left, upper, or lower edge. Dragging it in this method takes you to the outer parameter of the display. This shows you where you are on the display. 600 Series Industrial Mobile Computer User’s Guide

2-9

Page 28

Operation

SECTION 2

Panning Default Your hand-held computer comes from the factory with panning turned OFF. It is helpful to change the default to ON for setting up your system. After you are pleased with the way your application works change the default back to OFF.

Changing Default 1. Press I/O key to suspend your computer. 2. Copy System.ini to an ATA in the external slot or over HyperTerminal to a pc. 3. Locate your Windows System.ini file. 4. Go into the non--panning display configuration file and add a semicolon (;) in front of each line of code (do not change the non-panning display configuration line). 5. Go into the Panning display configuration and remove the semicolon (;) from in front of each line of code (do not change the Panning display configuration line). Below is shown how to modify this code. The column on the left is the default setting. Note that there is not a semicolon in front of the lines of code (excluding the first line that does contain a semicolon). The column of the right shows the lines after you add the semicolon to each line. Default Setting

Non-Panning Default Setting

;-- non-panning configuration FrameSeq=0xa000 HWModule=sc4_2Bbpp.d11 DisplayOrientation=1 DisplayColumns=240 DisplayRow=320 Panning=0 PanTrack=0 PanAbsolute=0 2-10

600 Series Industrial Mobile Computer User’s Guide

Panning

;-- panning configuration ;FrameSeq=0xa000 ;HWModule=SC4_2BPP.d11 ;DisplayOrientation=1 ;DisplayColumn=640 ;DisplayRow=480 ;Panning=1 ;PanTrack=1 ;PanAbsolute=1

Page 29

SECTION 2

Operation

The below column on the left shows the lines of code altered to allow panning. The right column on the right shows the default changed for to enable the panning to occur.

Setting Changed

Non- Panning Setting Changed

;-- non-panning configuration ;FrameSeq=0xa000 ;HWModule=SC4_2BPP.d11 ;DisplayOrientation=1 ;DisplayColumns=240 ;DisplayRow=320 ;Panning=0 ;PanTrack=0 ;PanAbsolute=0

Panning

;-- panning configuration FrameSeq=0xa000 HWModule=SC4_2BPP.d11 DisplayOrientation=1 DisplayColumns=640 DisplayRows=480 Panning=1 PanTrack=1 PanAbsolute=1

6. Save the changes to System.ini file. 7. Copy file from the external ATA or pc via HyperTerminal to boot ATA. You have to reboot for the new settings to take effect. After you are finished making changes, go back and change the default back to non-panning. To do this, of course, you reverse the process both for the non--panning and panning display configurations.

Downloading from Host Computer 1. Install your computer into a dock. 2. Download program into your computer. There are several ways to download your application. EXAMPLE:

You can load the program onto the CompactFlash card, install it into your computer, and select the program from the directory.

600 Series Industrial Mobile Computer User’s Guide

2-11

Page 30

Operation

SECTION 2

Opening your Application Press the [I/O] (Resume/Suspend) key. Opening the application totally depends on your application definition.

2-12

600 Series Industrial Mobile Computer User’s Guide